-46%

Schneider LC1D80F7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 80 A – 110 V AC 50/60 Hz coil

Schneider Electric
Availability:

Out of stock


9,720 EGP 18,001 EGP

Out of stock

Compare

Schneider LC1D80F7| TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 80 A – 110 V AC 50/60 Hz coil

Schneider LC1D80F7 Contactor: Detailed Overview

The Schneider LC1D80F7 is a robust and reliable contactor, designed for controlling motors and managing high-power loads in industrial applications. Renowned for its durability and performance, this contactor is an essential component in electrical control panels.

Technical Specifications

  • Model Number: LC1D80F7
  • Rated Current (AC-3): 80 A
  • Voltage Rating:
    • Coil Voltage: 110V AC
    • Operating Voltage: Up to 690V AC
  • Power Rating: Supports motors up to 37 kW at 400V
  • Auxiliary Contacts: 1 NO (Normally Open) + 1 NC (Normally Closed)
  • Frequency Range: 25 to 400 Hz
  • Mounting Type: Compatible with DIN rail or panel mounting
  • Dimensions: Compact, space-efficient design for streamlined integration.

Key Features

  1. Reliable Performance:
    Built to handle high operational demands with consistent and efficient performance.
  2. Compact and Flexible Design:
    Ideal for installations with limited space, offering flexibility in control panel designs.
  3. Enhanced Safety Standards:
    Equipped with superior insulation and adherence to global safety certifications for secure operations.
  4. Energy-Efficient Coil:
    The low-consumption coil minimizes energy usage while maintaining high performance.
  5. Modular Compatibility:
    Integrates seamlessly with Schneider Electric’s auxiliary modules, timers, and interlocking systems for tailored solutions.

Applications

The LC1D80F7 is suitable for a wide array of applications, including:

  • Motor Control: Efficiently controls motor starting, stopping, and reversing functions.
  • Industrial Automation: Plays a key role in automated systems requiring precise and reliable load management.
  • Power Distribution Systems: Ensures smooth and safe operation in factories and commercial facilities.
  • HVAC Systems: Supports efficient control of heating, ventilation, and air conditioning units.

Installation and Maintenance

  • Installation Guidelines:
    • Ensure proper alignment on DIN rails or panels for secure mounting.
    • Match the coil voltage to the system’s requirements before installation.
  • Maintenance Tips:
    • Regularly inspect for wear and debris to maintain optimal functionality.
    • Test auxiliary contacts periodically to ensure consistent operation.
Main
RangeTeSys
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-4
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 300 V DC 25…400 Hz
Power circuit: <= 690 V AC
[Ie] rated operational current125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
80 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage110 V AC 50/60 Hz
Complementary
Motor power kW22 kW at 220…230 V AC 50/60 Hz (AC-3)
37 kW at 380…400 V AC 50/60 Hz (AC-3)
45 kW at 415…440 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 660…690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
22 kW at 220…230 V AC 50/60 Hz (AC-3e)
37 kW at 380…400 V AC 50/60 Hz (AC-3e)
45 kW at 415…440 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp7.5 hp at 120 V AC 50/60 Hz for 1 phase motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
30 hp at 230/240 V AC 50/60 Hz for 3 phases motors
60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
125 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current640 A 40 °C – 10 s for power circuit
990 A 40 °C – 1 s for power circuit
135 A 40 °C – 10 min for power circuit
320 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance0.8 mOhm – Ith 125 A 50 Hz for power circuit
Power dissipation per pole5.1 W AC-3
12.5 W AC-1
5.1 W AC-3e
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability4 Mcycles
Electrical durability0.8 Mcycles 125 A AC-1 at Ue <= 440 V
1.5 Mcycles 80 A AC-3 at Ue <= 440 V
1.5 Mcycles 80 A AC-3e at Ue <= 440 V
Control circuit typeAC at 50/60 Hz standard
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.85…1.1 Uc (-40…55 °C):operational AC 60 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…55 °C):operational AC 50 Hz
1…1.1 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA26 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation6…10 W at 50/60 Hz
Operating time20…35 ms closing
6…20 ms opening
Maximum operating rate3600 cyc/h 60 °C
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 4…16 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: solid without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportRail
Plate
Environment
StandardsEN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product certificationsCCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Shocks contactor open (8 Gn for 11 ms)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Height127 mm
Width85 mm
Depth130 mm
Net weight1.59 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.500 cm
Package 1 Width13.400 cm
Package 1 Length14.200 cm
Package 1 Weight1.558 kg
Unit Type of Package 2S02
Number of Units in Package 25
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.048 kg
Unit Type of Package 3P06
Number of Units in Package 380
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight124.640 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : LC1D80F7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D80F7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 80 A – 110 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART