Schneider LC1D80Q7 Contactor: A Comprehensive Guide

The Schneider LC1D80Q7 is a premium contactor from Schneider Electric, designed for reliable motor control and industrial load management. Known for its robust construction and advanced features, it is widely used in demanding applications where efficiency and safety are paramount.

Technical Specifications

  • Model Number: LC1D80Q7
  • Rated Current (AC-3): 80 A
  • Voltage Rating:
    • Coil Voltage: 240V AC
    • Operating Voltage: Up to 690V AC
  • Power Rating: Suitable for motors up to 37 kW at 400V
  • Auxiliary Contacts: 1 NO (Normally Open) + 1 NC (Normally Closed)
  • Frequency Range: 25 to 400 Hz
  • Mounting Type: DIN rail or panel-mounted
  • Dimensions: Compact for space-saving integration.

Key Features

  1. High Reliability:
    Engineered for consistent performance in heavy-duty industrial environments.
  2. Compact Design:
    Designed to fit into tight spaces, making it ideal for modern electrical panels.
  3. Enhanced Compatibility:
    Works seamlessly with Schneider Electric’s auxiliary devices, timers, and add-ons for customized solutions.
  4. Safety First:
    Advanced insulation and compliance with global standards provide exceptional protection against electrical faults.
  5. Energy Efficiency:
    The energy-efficient coil minimizes power consumption, reducing operational costs.

Applications

The LC1D80Q7 is highly versatile and supports a range of applications, including:

  • Motor Control: Efficiently manages the operation of industrial motors.
  • Industrial Automation: Plays a key role in automated systems requiring precise load control.
  • HVAC Systems: Essential for heating, ventilation, and air conditioning operations.
  • Power Distribution: Suitable for managing electrical loads in factories and commercial establishments.

Installation and Maintenance

  • Installation Guidelines:
    • Mount on a DIN rail or directly on a panel using the provided slots.
    • Verify coil voltage and load compatibility before installation.
  • Maintenance Tips:
    • Conduct routine inspections to ensure the contactor is free from debris and damage.
    • Test auxiliary contacts periodically for consistent performance.

Advantages of Choosing Schneider Electric

Schneider Electric is globally recognized for delivering high-quality electrical products. The LC1D80Q7 contactor reflects the company’s expertise in power management and automation, offering unmatched durability and performance in industrial applications.

Main
RangeTeSys
Range of productTeSys Deca
Product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Motor control
Utilisation categoryAC-3
AC-3e
AC-4
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 300 V DC 25…400 Hz
Power circuit: <= 690 V AC
[Ie] rated operational current125 A (at <60 °C) at <= 1000 V AC AC-1 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage380 V AC 50/60 Hz
Complementary
Motor power kW22 kW at 220…230 V AC 50/60 Hz (AC-3)
37 kW at 380…400 V AC 50/60 Hz (AC-3)
45 kW at 415…440 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 660…690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
22 kW at 220…230 V AC 50/60 Hz (AC-3e)
37 kW at 380…400 V AC 50/60 Hz (AC-3e)
45 kW at 415…440 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 660…690 V AC 50/60 Hz (AC-3e)
Motor power hp7.5 hp at 120 V AC 50/60 Hz for 1 phase motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
30 hp at 230/240 V AC 50/60 Hz for 3 phases motors
60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility codeLC1D
Pole contact composition3 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
125 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current640 A 40 °C – 10 s for power circuit
990 A 40 °C – 1 s for power circuit
135 A 40 °C – 10 min for power circuit
320 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance0.8 mOhm – Ith 125 A 50 Hz for power circuit
Power dissipation per pole5.1 W AC-3
12.5 W AC-1
5.1 W AC-3e
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability4 Mcycles
Electrical durability0.8 Mcycles 125 A AC-1 at Ue <= 440 V
1.5 Mcycles 80 A AC-3 at Ue <= 440 V
1.5 Mcycles 80 A AC-3e at Ue <= 440 V
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.85…1.1 Uc (-40…55 °C):operational AC 60 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…55 °C):operational AC 50 Hz
1…1.1 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA26 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation6…10 W at 50/60 Hz
Operating time20…35 ms closing
6…20 ms opening
Maximum operating rate3600 cyc/h 60 °C
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 4…16 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: solid without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportRail
Plate
Environment
StandardsEN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product certificationsCCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Shocks contactor open (8 Gn for 11 ms)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Height127 mm
Width85 mm
Depth130 mm
Net weight1.59 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.000 cm
Package 1 Width13.500 cm
Package 1 Length9.500 cm
Package 1 Weight1.544 kg
Unit Type of Package 2S02
Number of Units in Package 25
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight8.050 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : LC1D80Q7 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D80Q7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 80 A – 380 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat