Schneider LC1D95E7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 95 A – 48 V AC 50/60 Hz coil

Schneider Electric
Availability:

In stock


11,721 EGP 21,706 EGP

In stock

Compare

Schneider LC1D95E7| TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 95 A – 48 V AC 50/60 Hz coil

Schneider LC1D95E7: A Comprehensive Description

Schneider LC1D95E7 is a versatile and efficient contactor designed for a wide range of industrial applications. With its robust construction, advanced features, and reliable performance, it has become a preferred choice among professionals in various industries.

Technical Specifications

Voltage and Current Ratings

The LC1D95E7 contactor is rated for up to 95 amps, making it suitable for handling heavy loads in industrial environments. It operates at voltage ratings ranging from 24 to 690 volts AC, ensuring compatibility with different power systems.

Coil Voltage

The coil voltage options available for the LC1D95E7 include 24 volts, 110 volts, 220 volts, and 380 volts, allowing for flexible installation and integration with existing control systems.

Number of Poles

This contactor features three poles, providing reliable switching for three-phase electrical circuits. Each pole is designed to handle specific phases of the electrical supply, ensuring efficient power distribution.

Control Voltage

The LC1D95E7 supports a wide range of control voltages, ranging from 24 to 230 volts AC/DC. This versatility enables seamless integration with various control systems and ensures reliable operation in diverse applications.

Features and Benefits

Magnetic Coil

The LC1D95E7 is equipped with a powerful magnetic coil that ensures rapid and reliable switching of electrical circuits. This feature enhances operational efficiency and minimizes downtime, resulting in improved productivity.

Compact Design

With its compact and space-saving design, the LC1D95E7 is ideal for installations where space is limited. Its streamlined profile allows for easy integration into control panels and equipment, optimizing use of available space.

Safety Features

it is equipped with advanced safety features to protect personnel and equipment from electrical hazards. These features include built-in overload protection, short-circuit protection, and shock-resistant construction, ensuring safe and reliable operation in any environment.

Applications

it contactor is suitable for a wide range of applications, including:

  • Industrial Machinery: It provides reliable switching for motors, pumps, compressors, and other heavy-duty equipment used in manufacturing and processing industries.
  • HVAC Systems: It is used in heating, ventilation, and air conditioning systems to control the operation of fans, blowers, and other HVAC components.
  • Commercial Equipment: It finds applications in commercial buildings, offices, and retail spaces for controlling lighting, elevators, escalators, and other electrical systems.

Installation Guide

Wiring Diagram

Before installing it contactor, refer to the provided wiring diagram to ensure correct connections and compatibility with your electrical system. Follow all local electrical codes and regulations during installation.

Mounting Instructions

The contactor can be mounted on a DIN rail or directly onto a panel using screws. Ensure that the mounting surface is clean, flat, and free from any obstructions to ensure proper installation and secure attachment.

Safety Precautions

When installing or servicing it contactor, always follow proper safety precautions to prevent electrical shocks or injuries. Disconnect power sources and use insulated tools when working on live circuits.

Maintenance and Troubleshooting

Regular Checks

Perform regular inspections of the contactor to ensure proper operation and detect any signs of wear or damage. Check for loose connections, overheating, or abnormal noises during operation.

Common Issues

Some common issues that may arise with it contactor include coil failure, contact welding, and overload tripping. Promptly address these issues to prevent further damage to the equipment and ensure uninterrupted operation.

Troubleshooting Tips

If you encounter any problems with it contactor, refer to the troubleshooting guide provided in the user manual. Follow the recommended steps to identify and resolve the issue, or consult a qualified technician for assistance if needed.

Comparison with Similar Products

Compared to its predecessor, it offers improved performance, enhanced features, and greater reliability. It incorporates advanced technology and design enhancements to meet the evolving needs of modern industrial applications.

LC1D95E7 vs. Competitors

When compared to similar products from other manufacturers, it stands out for its superior quality, durability, and value. Its competitive pricing and comprehensive warranty make it a cost-effective solution for various industrial and commercial applications.

Pricing and Availability

The price of the LC1D95E7 contactor varies depending on the supplier, quantity ordered, and additional features or accessories included. It is available through authorized distributors, retailers, and online suppliers, making it easily accessible to customers worldwide.

Warranty Information

Schneider LC1D95E7 is backed by a comprehensive warranty that covers defects in materials and workmanship for a specified period. The warranty terms and conditions may vary depending on the region and distributor, so be sure to review them carefully before making a purchase.

Conclusion

In conclusion, it is a versatile and reliable contactor that offers superior performance, advanced features, and robust construction. With its wide range of applications, easy installation, and comprehensive warranty, it is an ideal choice for professionals seeking a high-quality solution for their electrical control needs.

Main
Range TeSys
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-3e
AC-4
AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
[Ie] rated operational current 95 A (at <60 °C) at <= 440 V AC-3 for power circuit
125 A (at <60 °C) at <= 1000 V AC-1 for power circuit
95 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 48 V AC 50/60 Hz
Complementary
Motor power kW 25 kW at 220…230 V AC 50 Hz (AC-3)
45 kW at 380…400 V AC 50 Hz (AC-3)
45 kW at 415…440 V AC 50 Hz (AC-3)
55 kW at 500 V AC 50 Hz (AC-3)
45 kW at 660…690 V AC 50 Hz (AC-3)
15 kW at 400 V AC 50 Hz (AC-4)
25 kW at 220…230 V AC 50 Hz (AC-3e)
45 kW at 380…400 V AC 50 Hz (AC-3e)
45 kW at 415…440 V AC 50 Hz (AC-3e)
55 kW at 500 V AC 50 Hz (AC-3e)
45 kW at 660…690 V AC 50 Hz (AC-3e)
Motor power hp 7.5 hp at 120 V AC 60 Hz for 1 phase motors
15 hp at 230/240 V AC 60 Hz for 1 phase motors
30 hp at 200/208 V AC 60 Hz for 3 phases motors
30 hp at 230/240 V AC 60 Hz for 3 phases motors
60 hp at 460/480 V AC 60 Hz for 3 phases motors
60 hp at 575/600 V AC 60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
125 A (at 60 °C) for power circuit
Irms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A 40 °C – 1 s for power circuit
800 A 40 °C – 10 s for power circuit
400 A 40 °C – 1 min for power circuit
135 A 40 °C – 10 min for power circuit
140 A – 100 ms for signalling circuit
120 A – 500 ms for signalling circuit
100 A – 1 s for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm – Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1
7.2 W AC-3
7.2 W AC-3e
[Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 4 Mcycles
Electrical durability 1.2 Mcycles 95 A AC-3
1.3 Mcycles 125 A AC-1
1.2 Mcycles 95 A AC-3e
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.8…1.1 Uc (-40…55 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…55 °C):operational AC 60 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
1…1.1 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 6…10 W at 50/60 Hz
Operating time 20…35 ms closing
6…20 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 4…16 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: solid without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product certifications CCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Shocks contactor open (8 Gn for 11 ms)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Height 127 mm
Width 85 mm
Depth 130 mm
Net weight 1.61 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.5 cm
Package 1 Width 13.5 cm
Package 1 Length 14 cm
Package 1 Weight 1.559 kg
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 8.255 kg
Unit Type of Package 3 P06
Number of Units in Package 3 80
Package 3 Height 80 cm
Package 3 Width 80 cm
Package 3 Length 60 cm
Package 3 Weight 140.42 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LC1D95E7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D95E7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 95 A – 48 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024