Let's Chat
-46%

Schneider LC1D95F7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 95 A – 110 V AC 50/60 Hz coil

Schneider Electric
Availability:

In stock


11,721 EGP 21,706 EGP

In stock

Compare

Schneider LC1D95F7| TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 95 A – 110 V AC 50/60 Hz coil

Schneider LC1D95F7: An Overview of a Powerful Contactor

it is a highly efficient and reliable contactor designed for various industrial applications. With its robust construction and advanced features, it offers unparalleled performance and durability. In this article, we will delve into the specifications, features, applications, installation, benefits, and maintenance tips of it.

Specifications of Schneider LC1D95F7

Voltage Rating

it contactor operates at a voltage rating suitable for industrial power systems, ensuring compatibility with a wide range of electrical installations.

Current Rating

With a high current rating,it contactor can handle substantial electrical loads, making it ideal for heavy-duty applications in industrial settings.

Coil Voltage

The coil voltage of it contactor ensures efficient activation and deactivation, contributing to smooth operation and energy efficiency.

Features it

Compact Design

Despite its high power handling capacity, itcontactor boasts a compact design, saving valuable space in control panels and electrical enclosures.

High Performance

Equipped with advanced technology and quality components, the Schneider LC1D95F7 delivers exceptional performance under various operating conditions, ensuring uninterrupted operation of industrial equipment.

Reliable Operation

Built to withstand harsh environments and rigorous usage, it contactor offers reliable operation, minimizing downtime and enhancing productivity in industrial applications.

Applications it

The Schneider LC1D95F7 contactor finds wide-ranging applications in various industries, including:

  • Industrial Machinery: Used in motor control circuits of pumps, conveyors, and other machinery.
  • HVAC Systems: Employed in heating, ventilation, and air conditioning systems for controlling compressors and fans.
  • Automation Systems: Integrated into automated production lines and machinery for precise control of electrical loads.

Installation and Wiring

Mounting Options

The LC1D95F7 contactor can be easily mounted on DIN rails or directly onto a panel, providing flexibility in installation and saving time during setup.

Wiring Diagram

A detailed wiring diagram is provided with it contactor, ensuring correct and safe installation in compliance with electrical regulations.

Benefits of Using it

Efficiency Improvement

By offering reliable and precise control over electrical loads, it contactor helps improve overall system efficiency, leading to energy savings and reduced operating costs.

Cost Savings

The durability and longevity of it contactor result in lower maintenance expenses and reduced downtime, translating into significant cost savings for industrial users.

Maintenance Tips

Regular Inspection

Periodic inspection of it contactor is essential to ensure proper operation and detect any signs of wear or damage promptly.

Cleaning Procedures

Simple cleaning procedures, such as removing dust and debris from the contactor’s surface, can help maintain optimal performance and extend its service life.

Conclusion

In conclusion, the Schneider LC1D95F7 contactor stands out as a reliable and efficient solution for industrial control applications. With its robust construction, advanced features, and versatile performance, it meets the diverse needs of modern industrial environments, contributing to enhanced productivity and cost savings.

FAQs

  1. Is the Schneider LC1D95F7 contactor suitable for outdoor use?
    • Yes, the LC1D95F7 contactor is designed to withstand outdoor conditions, provided it is installed in a suitable enclosure to protect it from environmental elements.
  2. Can the Schneider LC1D95F7 contactor be used with variable frequency drives (VFDs)?
    • Yes, the LC1D95F7 contactor is compatible with VFDs and can be integrated into control systems for motor speed control applications.
  3. What is the warranty period for the Schneider LC1D95F7 contactor?
    • The Schneider LC1D95F7 contactor typically comes with a standard warranty period of [insert warranty period], subject to terms and conditions.
  4. Does the Schneider LC1D95F7 contactor support remote control and monitoring?
    • Yes, Schneider LC1D95F7 contactors can be integrated into control systems with remote control and monitoring capabilities for enhanced functionality and convenience.
  5. Where can I find technical support and documentation for the Schneider LC1D95F7 contactor?
    • Technical support, manuals, and documentation for the Schneider LC1D95F7 contactor are available through Schneider Electric’s official website and authorized distributors.
Main
Range TeSys
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-3e
AC-4
AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
[Ie] rated operational current 95 A (at <60 °C) at <= 440 V AC-3 for power circuit
125 A (at <60 °C) at <= 1000 V AC-1 for power circuit
95 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 110 V AC 50/60 Hz
Complementary
Motor power kW 25 kW at 220…230 V AC 50 Hz (AC-3)
45 kW at 380…400 V AC 50 Hz (AC-3)
45 kW at 415…440 V AC 50 Hz (AC-3)
55 kW at 500 V AC 50 Hz (AC-3)
45 kW at 660…690 V AC 50 Hz (AC-3)
15 kW at 400 V AC 50 Hz (AC-4)
25 kW at 220…230 V AC 50 Hz (AC-3e)
45 kW at 380…400 V AC 50 Hz (AC-3e)
45 kW at 415…440 V AC 50 Hz (AC-3e)
55 kW at 500 V AC 50 Hz (AC-3e)
45 kW at 660…690 V AC 50 Hz (AC-3e)
Motor power hp 7.5 hp at 120 V AC 60 Hz for 1 phase motors
15 hp at 230/240 V AC 60 Hz for 1 phase motors
30 hp at 200/208 V AC 60 Hz for 3 phases motors
30 hp at 230/240 V AC 60 Hz for 3 phases motors
60 hp at 460/480 V AC 60 Hz for 3 phases motors
60 hp at 575/600 V AC 60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
125 A (at 60 °C) for power circuit
Irms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A 40 °C – 1 s for power circuit
800 A 40 °C – 10 s for power circuit
400 A 40 °C – 1 min for power circuit
135 A 40 °C – 10 min for power circuit
140 A – 100 ms for signalling circuit
120 A – 500 ms for signalling circuit
100 A – 1 s for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm – Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1
7.2 W AC-3
7.2 W AC-3e
[Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 4 Mcycles
Electrical durability 1.2 Mcycles 95 A AC-3
1.3 Mcycles 125 A AC-1
1.2 Mcycles 95 A AC-3e
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.8…1.1 Uc (-40…55 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…55 °C):operational AC 60 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
1…1.1 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 6…10 W at 50/60 Hz
Operating time 20…35 ms closing
6…20 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 4…16 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: solid without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate
Environment
Standards EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product certifications CCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Shocks contactor open (8 Gn for 11 ms)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Height 127 mm
Width 85 mm
Depth 130 mm
Net weight 1.61 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.000 cm
Package 1 Width 13.500 cm
Package 1 Length 10.000 cm
Package 1 Weight 1.554 kg
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 8.110 kg
Unit Type of Package 3 P06
Number of Units in Package 3 80
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 133.700 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LC1D95F7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1D95F7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 95 A – 110 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024