Introduction to Schneider LC1DT32M7

it is a powerful and reliable contactor designed for a wide range of industrial applications. It is part of Schneider Electric’s TeSys D series, known for its high performance and durability. This contactor is built to provide efficient motor control and ensure smooth operation in various industrial settings.

Specifications of Schneider LC1DT32M7

it comes with the following specifications:

Voltage Rating

The contactor is rated for operating voltages up to 690 volts, making it suitable for both low and high voltage applications.

Power Rating

With a power rating of 32 amps, it can handle heavy loads with ease, making it ideal for demanding industrial environments.

Coil Voltage

The contactor features a coil voltage of 24 volts, ensuring reliable activation and deactivation of the switching mechanism.

Contact Configuration

It is equipped with 3 normally open (NO) main poles, allowing for efficient control of electrical circuits.

Control Circuit Voltage

it operates on a control circuit voltage of 220-240 volts AC, ensuring compatibility with standard industrial power systems.

Features

Compact Design

Despite its robust performance, it boasts a compact and space-saving design, making it easy to integrate into existing electrical panels and enclosures.

Reliable Performance

Built with high-quality materials and precision engineering, it delivers consistent and reliable performance, ensuring uninterrupted operation even in harsh industrial environments.

Easy Installation

The contactor is designed for easy installation, with clearly marked terminals and intuitive wiring diagrams, allowing for quick and hassle-free setup.

Applications

Schneider LC1DT32M7 finds wide application in various industrial sectors, including:

  • Industrial automation
  • Motor control
  • HVAC (Heating, Ventilation, and Air Conditioning) systems

Benefits of Using Schneider LC1DT32M7

Energy Efficiency

By providing efficient motor control, Schneider LC1DT32M7 helps optimize energy usage, reducing overall power consumption and operational costs.

Cost-Effectiveness

With its durable construction and long service life, it offers excellent value for money, minimizing the need for frequent replacements or repairs.

Durability

Constructed to withstand the rigors of industrial use, Schneider LC1DT32M7 is built to last, ensuring reliable performance even in demanding operating conditions.

Installation Process of Schneider LC1DT32M7

Installing i is a straightforward process that can be completed in a few simple steps:

  1. Ensure power to the circuit is switched off before starting installation.
  2. Mount the contactor securely in the desired location using appropriate mounting hardware.
  3. Connect the control circuit wires to the designated terminals on the contactor, following the wiring diagram provided.
  4. Verify proper connection and insulation of all wires before restoring power to the circuit.

Maintenance Tips

To ensure optimal performance and longevity, it is recommended to follow these maintenance tips:

  • Perform regular visual inspections to check for signs of wear or damage.
  • Clean the contactor and surrounding area periodically to remove dust and debris that may affect performance.
  • Replace worn or damaged parts promptly to prevent further issues.

Despite its reliability, Schneider LC1DT32M7 may encounter occasional issues. Here are some common problems and their solutions:

Overheating

Ensure proper ventilation and cooling for the contactor to prevent overheating. Check for loose connections or overloaded circuits that may contribute to excessive heat buildup.

Coil Failure

Inspect the coil for signs of damage or wear, such as burnt insulation or corrosion. Replace the coil if necessary to restore proper functionality.

Contact Welding

If the contacts become welded together due to excessive current or arcing, carefully separate them using insulated tools. Investigate the root cause of the welding and address any underlying issues to prevent recurrence.

Comparison with Other Similar Products

Schneider LC1DT32M7 stands out from its competitors due to its superior performance, reliability, and cost-effectiveness. Compared to other contactors in its class, it offers unmatched durability and efficiency, making it the preferred choice for industrial applications.

Conclusion

Schneider LC1DT32M7 is a versatile and reliable contactor that offers superior performance and durability for a wide range of industrial applications. With its compact design, easy installation, and energy-efficient operation, it provides an ideal solution for motor control and automation needs.

Main
Range TeSys
TeSys Deca
Range of product TeSys Deca
product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1
AC-3
AC-3e
AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
Complementary
Compatibility code LC1D
Pole contact composition 4 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
32 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
300 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 300 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 40 A 40 °C – 10 min for power circuit
84 A 40 °C – 1 min for power circuit
145 A 40 °C – 10 s for power circuit
240 A 40 °C – 1 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
50 A gG at <= 690 V coordination type 1 for power circuit
35 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 2.5 mOhm – Ith 32 A 50 Hz for power circuit
Power dissipation per pole 2.5 W AC-1
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 15 Mcycles
Electrical durability 1 Mcycles 32 A AC-1 at Ue <= 440 V
Control circuit type AC at 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W at 50/60 Hz
Operating time 4…19 ms opening
12…22 ms closing
Maximum operating rate 3600 cyc/h 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…16 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² – cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 1.8 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.8 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 1.8 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Plate
Rail
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
Product certifications DNV
GL
CCC
LROS (Lloyds register of shipping)
RINA
BV
GOST
UL
CSA
CB
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0…3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)
Height 91 mm
Width 45 mm
Depth 99 mm
Net weight 0.425 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.800 cm
Package 1 Width 9.800 cm
Package 1 Length 12.000 cm
Package 1 Weight 466.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 16
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 7.997 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1DT32M7 | TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 32 A – 220 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024