-46%

Schneider LC1DT60AM7 | TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 220 V AC 50/60 Hz coil

Schneider Electric
Availability:

In stock


5,587 EGP 10,347 EGP

In stock

Compare

Schneider LC1DT60AM7| TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 220 V AC 50/60 Hz coil

Schneider LC1DT60AM7: The Ultimate Contactor for Your Electrical Needs

it is a highly reliable and efficient contactor designed to meet the diverse needs of electrical applications. Whether you’re in the industrial sector or residential settings, this contactor offers superior performance and durability. In this article, we’ll delve into the various aspects of it, from its specifications to its applications, installation guide, and more.

Specifications

 contactor is designed for AC-3 utilization category, making it suitable for controlling electrical circuits up to 690 volts. With a rated operational current of 60 amps, it can efficiently handle heavy loads, ensuring smooth operation without any interruptions. Additionally, it features a compact design, making it easy to integrate into existing electrical systems.

Applications of LC1DT60AM7

From motor control to HVAC systems and lighting applications, Schneider LC1DT60AM7 finds its use across various industries. Its versatility makes it an ideal choice for both commercial and industrial settings where reliable electrical control is essential. Whether it’s starting and stopping motors or controlling lighting circuits, this contactor delivers exceptional performance.

Benefits of Using

  • Reliability: it is known for its reliability, ensuring uninterrupted operation even in harsh environments.
  • Energy Efficiency: With its efficient design, it helps minimize energy consumption, leading to cost savings.
  • Durability: Built to withstand heavy-duty use, this contactor offers long-term durability and performance.
  • Ease of Installation: The compact design and user-friendly features of LC1DT60AM7 make installation quick and hassle-free.

Installation Guide

Installing it is straightforward, but it’s essential to follow the manufacturer’s guidelines to ensure proper operation. Begin by identifying the suitable location for the contactor, considering factors such as accessibility and ventilation. Next, carefully wire the contactor according to the provided wiring diagram, ensuring proper connections and cable sizing. Once installed, perform a thorough inspection to verify correct wiring and secure any loose connections.

Maintenance Tips

To ensure optimal performance and longevity of it, regular maintenance is crucial. Inspect the contactor periodically for signs of wear or damage, such as overheating or corrosion. Clean the contactor and surrounding area to remove any dust or debris that may affect performance. Additionally, conduct routine tests to verify proper operation and address any issues promptly.

Troubleshooting Common Issues

Despite its reliability, it may encounter occasional issues that require troubleshooting. Common problems include faulty connections, overheating, and coil failures. Refer to the user manual for troubleshooting steps and consult with a qualified technician if necessary.

Comparison with Similar Products

When choosing a contactor for your electrical needs, it’s essential to compare Schneider LC1DT60AM7 with similar products on the market. Consider factors such as price, specifications, and customer reviews to make an informed decision.

Customer Reviews and Feedback

Feedback from customers who have used Schneider LC1DT60AM7 can provide valuable insights into its performance and reliability. Check online reviews and testimonials to gauge user satisfaction and determine if it meets your requirements.

Warranty Information

Schneider LC1DT60AM7 comes with a standard warranty that covers manufacturing defects and malfunctions. Be sure to register your product to activate the warranty and contact Schneider Electric for any warranty-related inquiries or claims.

Where to Buy

Schneider LC1DT60AM7 is available through authorized distributors and retailers worldwide. Check the Schneider Electric website or contact their customer service for assistance in locating a reputable seller in your area.

Price Range

The price of Schneider LC1DT60AM7 may vary depending on factors such as quantity, location, and seller. Compare prices from different sources to find the best deal while ensuring product authenticity and reliability.

Conclusion

In conclusion, Schneider LC1DT60AM7 stands out as a top-tier contactor offering unparalleled performance, reliability, and versatility. Whether you’re a professional electrician or a DIY enthusiast, this contactor is sure to meet your electrical control needs with ease. Invest in Schneider LC1DT60AM7 for peace of mind and efficient operation of your electrical systems.

Main
RangeTeSys
TeSys Deca
Range of productTeSys Deca
product or component typeContactor
Device short nameLC1D
Contactor applicationResistive load
Utilisation categoryAC-1
Poles description4P
[Ue] rated operational voltagePower circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Complementary
Compatibility codeLC1D
Pole contact composition4 NO
Protective coverWith
[Ith] conventional free air thermal current10 A (at 60 °C) for signalling circuit
60 A (at 60 °C) for power circuit
Irms rated making capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 40 °C – 10 s for power circuit
720 A 40 °C – 1 s for power circuit
72 A 40 °C – 10 min for power circuit
165 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating10 A gG for signalling circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance1.6 mOhm – Ith 60 A 50 Hz for power circuit
Power dissipation per pole5.8 W AC-1
[Ui] rated insulation voltagePower circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability6 Mcycles
Electrical durability1.4 Mcycles 60 A AC-1 at Ue <= 440 V
Control circuit typeAC at 50/60 Hz
Coil technologyWithout built-in suppressor module
Control circuit voltage limits0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation4…5 W at 50/60 Hz
Operating time4…19 ms opening
12…26 ms closing
Maximum operating rate3600 cyc/h 60 °C
Maximum operating rate3600 cyc/h at 60 °C
Connections – terminalsControl circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: flexible without cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: flexible with cable end
Power circuit: EverLink BTR screw connectors 1 1…35 mm² – cable stiffness: solid without cable end
Power circuit: EverLink BTR screw connectors 2 1…25 mm² – cable stiffness: solid without cable end
Tightening torqueControl circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on EverLink BTR screw connectors – with screwdriver pozidriv No 2
Auxiliary contact composition1 NO + 1 NC
Auxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency25…400 Hz
Minimum switching voltage17 V for signalling circuit
Minimum switching current5 mA for signalling circuit
Insulation resistance> 10 MOhm for signalling circuit
Non-overlap time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting supportRail
Plate
Environment
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
Product certificationsLROS (Lloyds register of shipping)
UL
GOST
BV
CCC
CSA
RINA
DNV
GL
IP degree of protectionIP20 front face conforming to IEC 60529
Protective treatmentTH conforming to IEC 60068-2-30
Climatic withstandconforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device-40…60 °C
60…70 °C with derating
Operating altitude0…3000 m
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Mechanical robustnessVibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
Height122 mm
Width70 mm
Depth120 mm
Net weight1.09 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8 cm
Package 1 Width14 cm
Package 1 Length15 cm
Package 1 Weight1.097 kg
Unit Type of Package 2S02
Number of Units in Package 27
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight8.041 kg
Unit Type of Package 3P06
Number of Units in Package 3112
Package 3 Height77 cm
Package 3 Width80 cm
Package 3 Length60 cm
Package 3 Weight138.644 kg
Contractual warranty
Warranty18 months

Main documents

DatasheetDownload Datasheet
Product datasheetLC1DT60AM7
Instruction sheet
Download
Catalogue
Download
CAD Files
Download
Environmental disclosureDownload

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1DT60AM7 | TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 220 V AC 50/60 Hz coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat