Let's Chat
-46%
,

Schneider LC1E250M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,250A,220V AC coil,50Hz

Schneider Electric
Availability:

Out of stock


LC1E250M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,250A,220V AC coil,50Hz

17,218 EGP 31,886 EGP

Out of stock

Compare

Schneider LC1E250M5| Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,250A,220V AC coil,50Hz

Schneider LC1E250M5 Description

it is a widely used contactor designed for electrical control applications. It offers robust performance and reliability, making it suitable for various industrial and commercial settings. In this article, we will delve into the description, specifications, applications, benefits, installation process, maintenance tips, and safety considerations it.

Introduction

it is a part of the LC1E series of contactors manufactured by Schneider Electric. These contactors are known for their high-quality construction and efficient operation. it is specifically designed to handle heavy loads and provide long-term durability in demanding environments.

Understanding the Specifications

Voltage Rating

The voltage rating of it is crucial for determining its compatibility with different electrical systems. It typically operates within a voltage range specified by the manufacturer to ensure safe and reliable performance.

Current Rating

The current rating indicates the maximum current that it can handle without overheating or malfunctioning. It is an essential parameter to consider when selecting the appropriate contactor for a specific application.

Applications it

it finds widespread use in various industries and applications, including:

  • HVAC systems
  • Motor control
  • Lighting control
  • Industrial machinery
  • Pump control
  • Conveyor systems

Benefits of Using it

  • High reliability and durability
  • Precise control of electrical circuits
  • Compact design for space-saving installation
  • Wide operating temperature range
  • Compatible with standard control systems
  • Easy integration into existing setups

Comparison with Similar Products

When compared to similar contactors on the market, it stands out for its superior performance, reliability, and longevity. Its robust construction and advanced features make it a preferred choice for demanding applications.

Installation Process

Installing it involves several steps, including:

  1. Selecting the appropriate mounting location.
  2. Ensuring proper electrical connections.
  3. Securing the contactor in place using suitable fasteners.
  4. Testing the functionality of the contactor before putting it into operation.

Maintenance and Troubleshooting Tips

To maintain optimal performance and longevity of it, follow these tips:

  • Regularly inspect for signs of wear or damage.
  • Keep the contactor clean and free from debris.
  • Check electrical connections for tightness and corrosion.
  • Address any malfunction or abnormal operation promptly to prevent further damage.

Safety Considerations

When working with it or any electrical equipment, observe the following safety precautions:

  • Disconnect power before installation or maintenance.
  • Use appropriate personal protective equipment (PPE).
  • Follow manufacturer’s instructions and guidelines.
  • Consult qualified professionals for complex installations or repairs.

Conclusion

it is a versatile and reliable contactor suitable for various electrical control applications. With its robust construction, advanced features, and ease of installation, it offers unparalleled performance and longevity. By understanding its specifications, applications, benefits, and safety considerations, users can maximize the efficiency and safety of their electrical systems.

Main
Range Easy TeSys
range of product Easy TeSys Control
product or component type Contactor
Device short name LC1E
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-3e
AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current 250 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
190 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
300 A (at <40 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 220 V AC 50 Hz
Complementary
Motor power kW 75 kW at 220…230 V AC 50/60 Hz
132 kW at 380…400 V
140 kW at 415 V
140 kW at 440 V
160 kW at 500 V
160 kW at 660…690 V
Pole contact composition 3 NO
[Ith] conventional free air thermal current 300 A (at 40 °C) for power circuit
Irms rated making capacity 2500 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity 2000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1800 A 40 °C – 10 s for power circuit
Associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
315 A gG at <= 690 V coordination type 1 for power circuit
Average impedance 0.32 mOhm – Ith 300 A 50 Hz for power circuit
Power dissipation per pole 20 W AC-3
29 W AC-1
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability 5000000 cycles
Electrical durability 200000 cycles AC-1
700000 cycles AC-3
Control circuit type AC at 50 Hz
Control circuit voltage limits 0.85…1.1 Uc (-5…55 °C):operational 50 Hz
0.35…0.55 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA 805 VA 50 Hz cos phi 0.3 (at 20 °C)
970 VA 60 Hz cos phi 0.3 (at 20 °C)
Hold-in power consumption in VA 55 VA 50 Hz cos phi 0.3 (at 20 °C)
66 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 18…24 W for control circuit
Operating time 20…35 ms on closing
7…15 ms on opening
Maximum operating rate 1200 cyc/h 55 °C
Connections – terminals Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: cable with lug – external diameter: 185 mm
Power circuit: bars 2 – busbar cross section: 32 x 4 mm
Tightening torque Control circuit: 1.2 N.m
Power circuit: 35 N.m
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
mounting support Plate
Environment
Standards IEC 60947-1
IEC 60947-4-1
IEC 60947-5-1
Product certifications EAC
CE
IP degree of protection IP00 conforming to IEC 60529
Permissible ambient air temperature around the device -20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Mechanical robustness Vibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor open (6 Gn for 11 ms)
Shocks contactor closed (7 Gn for 11 ms)
Height 197 mm
Width 168.5 mm
Depth 181 mm
net weight 4.7 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 21.500 cm
Package 1 Width 22.000 cm
Package 1 Length 24.000 cm
Package 1 Weight 5.320 kg
Unit Type of Package 2 S06
Number of Units in Package 2 12
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 73.000 kg
Contractual warranty
Warranty 18 months

Main documents

Datasheet Download Datasheet
Product datasheet LC1E250M5
Instruction sheet
LC1E250M5
Catalog LC1E250M5
Environmental disclosure
LC1E250M5
CAD Files LC1E250M5

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1E250M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,250A,220V AC coil,50Hz”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024