-46%
,

Schneider LC1E2510M5 | Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,25A,220V AC coil,50Hz,1NO auxiliary contact

Schneider Electric
Availability:

Out of stock


1,137.60 EGP 2,106.70 EGP

Out of stock

Schneider LC1E2510M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,25A,220V AC coil,50Hz,1NO auxiliary contact

Schneider LC1E2510M5: Your Comprehensive Guide

Introduction to Schneider LC1E2510M5

Schneider LC1E2510M5 is a robust and reliable contactor designed for various industrial applications. It belongs to Schneider Electric’s LC1E series, renowned for its performance and durability in controlling electrical circuits..

Applications

Schneider LC1E2510M5 finds wide-ranging applications across industries, including:

  • Manufacturing plants
  • Commercial buildings
  • HVAC systems
  • Water treatment facilities
  • Mining operations

Advantages of Schneider LC1E2510M5

  • Robust construction ensures durability and longevity.
  • Precise engineering guarantees reliable performance under varying conditions.
  • Easy installation and compatibility with standard electrical systems streamline integration processes.
  • Enhanced safety features protect against electrical faults and overloads.
  • Compact design saves space and allows for flexible installation options.

Installation Guide

Installing it contactor is straightforward and can be accomplished using standard electrical wiring practices. Here’s a brief guide:

  1. Ensure that the power supply to the circuit is switched off.
  2. Select an appropriate location for mounting the contactor, considering accessibility and ventilation requirements.
  3. Connect the control wires to the designated terminals on the contactor, following the manufacturer’s instructions.
  4. Securely fasten the contactor to the mounting surface using suitable hardware.
  5. Double-check all connections to ensure proper wiring and alignment.
  6. Restore power to the circuit and test the contactor’s operation.

Maintenance Tips

To ensure optimal performance and longevity of it contactor, follow these maintenance tips:

  • Regularly inspect for signs of wear or damage, such as overheating or corrosion.
  • Keep the contactor and its surroundings clean and free from debris.
  • Test the contactor periodically to verify its functionality.
  • Replace any worn-out components or damaged parts promptly.
  • Follow the manufacturer’s recommendations for maintenance intervals and procedures.

Troubleshooting

In the event of operational issues or malfunctions, refer to the troubleshooting guide provided by Schneider Electric. Common troubleshooting steps may include:

  • Checking for loose connections or faulty wiring
  • Inspecting the contactor for signs of damage or wear
  • Testing the coil voltage and continuity of the contactor
  • Consulting technical support or contacting a certified electrician for assistance

Comparisons with Similar Products

When comparing it with similar products in the market, consider factors such as:

  • Price
  • Performance specifications
  • Brand reputation
  • Warranty coverage
  • Additional features or functionalities

Conclusion

it stands out as a dependable solution for controlling electrical circuits in diverse industrial applications. With its robust construction, reliable performance, and ease of installation, it offers significant advantages to users seeking efficient and safe electrical control solutions.

Main
Range Easy TeSys
range of product Easy TeSys Control
product or component type Contactor
Device short name LC1E
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-3e
AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current 25 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
25 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
32 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 220 V AC 50 Hz
Complementary
Motor power kW 5.5 kW at 220…230 V AC 50/60 Hz
11 kW at 380…400 V
11 kW at 415 V
11 kW at 440 V
15 kW at 500 V
15 kW at 660…690 V
Pole contact composition 3 NO
[Ith] conventional free air thermal current 32 A (at 55 °C) for power circuit
Irms rated making capacity 250 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity 200 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 240 A 40 °C – 10 s for power circuit
120 A 40 °C – 60 s for power circuit
50 A 40 °C – 600 s for power circuit
Associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
Average impedance 2.5 mOhm – Ith 32 A 50 Hz for power circuit
Power dissipation per pole 1.6 W AC-3
3.2 W AC-1
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability 10000000 cycles
Electrical durability 1200000 cycles AC-3
350000 cycles AC-1
Control circuit type AC at 50 Hz
Control circuit voltage limits 0.85…1.1 Uc (-5…55 °C):operational 50 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA 95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 8.3 VA 50 Hz cos phi 0.3 (at 20 °C)
8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 2…3 W for control circuit
Operating time 12…22 ms on closing
4…19 ms on opening
Maximum operating rate 1800 cyc/h 60 °C
Connections – terminals Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Tightening torque Control circuit: 1.2 N.m
Power circuit: 1.5 N.m
Auxiliary contact composition 1 NO
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
mounting support Plate
DIN rail
Environment
Standards IEC 60947-1
IEC 60947-4-1
IEC 60947-5-1
Product certifications EAC
CE
IP degree of protection IP2X conforming to IEC 60529
Protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device -20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Mechanical robustness Vibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height 74 mm
Width 45 mm
Depth 85 mm
net weight 0.36 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.000 cm
Package 1 Width 7.600 cm
Package 1 Length 8.200 cm
Package 1 Weight 357.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 36
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 13.347 kg
Unit Type of Package 3 P06
Number of Units in Package 3 576
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 222.052 kg
Contractual warranty
Warranty 18 months