Technical Specifications

  • Model Number: LC1E2510M7
  • Series: Easy TeSys LC1E
  • Contactor Type: Electromagnetic Contactor
  • Number of Poles: 3P (Three-Pole)
  • Main Contact Configuration: 3 Normally Open (3NO)
  • Auxiliary Contact Configuration: 1 Normally Open (1NO)
  • Utilization Category: AC-3
  • Rated Operational Voltage (Ue): ≤ 440V AC
  • Rated Current (Ie) for AC-3: 25A
  • Coil Voltage: 220V AC (50/60Hz)
  • Coil Consumption: 9VA (holding), 70VA (inrush)
  • Mechanical Durability: Up to 10 million operations
  • Electrical Durability: Up to 1 million operations at rated load
  • Operating Temperature Range: -5°C to +55°C
  • Mounting Type: DIN Rail or Panel Mounting
  • Connection Type: Screw Terminals
  • Certifications & Standards: IEC 60947-4-1, UL, CSA, CE

Key Features

  1. Reliable Motor Control

    • Suitable for direct motor starting, reversing, and switching operations in AC-3 applications.
  2. High Durability and Longevity

    • Offers up to 10 million mechanical operations and 1 million electrical operations, ensuring long-term reliability.
  3. Compact and Space-Saving Design

    • Optimized for control panels and industrial motor control centers, reducing panel space usage.
  4. Versatile Auxiliary Contact (1NO)

    • Allows for feedback signaling, interlocking, and control circuit integration.
  5. Efficient Coil Performance (220V AC, 50/60Hz)

    • Operates on a standard voltage, making it suitable for various industrial power systems.
  6. Flexible Mounting Options

    • Supports both DIN rail and panel mounting, making installation easy and adaptable.
  7. Robust and Industrial-Grade Build

    • Designed for harsh environments, withstanding high temperatures and electrical loads.
  8. Compliant with Global Standards

    • Certified under IEC 60947-4-1, UL, CSA, and CE, ensuring safe and efficient operation worldwide.

Applications

  • Motor Control & Automation
    • Used in motor starters, pump control systems, conveyor systems, and compressors.
  • Industrial Machinery & Equipment
    • Controls motors in manufacturing, material handling, and industrial automation systems.
  • HVAC Systems
    • Ideal for air conditioning units, ventilation systems, and heating systems.
  • Power Distribution & Control Panels
    • Ensures reliable switching in electrical distribution boards.
  • Lighting & Heating Circuits
    • Used in commercial and industrial lighting and heating applications.

brands

Schneider Electric

Main
RangeEasy TeSys
Range of productEasy TeSys Control
Product or component typeContactor
Device short nameLC1E
contactor applicationMotor control
Resistive load
Utilisation categoryAC-1
AC-3
poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current25 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
36 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50/60 Hz
Complementary
Motor power kW5.5 kW at 220…230 V AC 50/60 Hz
11 kW at 380…400 V
11 kW at 415 V
11 kW at 440 V
15 kW at 500 V
15 kW at 660…690 V
Pole contact composition3 NO
[Ith] conventional free air thermal current36 A (at 55 °C)
Irms rated making capacity250 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity200 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current240 A 40 °C – 10 s for power circuit
120 A 40 °C – 60 s for power circuit
50 A 40 °C – 600 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
Average impedance2.5 mOhm – Ith 36 A 50 Hz for power circuit
Power dissipation per pole1.6 W AC-3
3.2 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability10000000 cycles
Electrical durability1200000 cycles AC-3
350000 cycles AC-1
Control circuit typeAC at 50/60 Hz
Control circuit voltage limits0.85…1.1 Uc (-5…55 °C):operational 50/60 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50/60 Hz
Inrush power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA8.3 VA 50 Hz cos phi 0.3 (at 20 °C)
8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W for control circuit
Operating time12…22 ms on closing
4…19 ms on opening
Maximum operating rate1800 cyc/h 60 °C
Connections – terminalsControl circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 1.5 N.m
Auxiliary contact composition1 NO
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
mounting supportDIN rail
Plate
Environment
StandardsIEC 60947-1
IEC 60947-4-1
IEC 60947-5-1
Product certificationsEAC
CE
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height74 mm
Width45 mm
Depth85 mm
Net weight0.36 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.500 cm
Package 1 Width7.500 cm
Package 1 Length5.000 cm
Package 1 Weight363.000 g
Unit Type of Package 2S02
Number of Units in Package 236
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight13.646 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1E2510M7 | Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,25A,220V AC coil,50/60Hz,1NO auxiliary contact”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat