-46%
,

Schneider LC1E3810M5 | Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,38A,220V AC coil,50Hz,1NO auxiliary contact

Schneider Electric
Availability:

In stock


LC1E3810M5 | Contactor,EasyPact TVS,3P(3NO),AC-3,<=440V,38A,220V AC coil,50Hz,1NO auxiliary contact

2,010 EGP 3,722 EGP

In stock

Compare

Schneider LC1E3810M5 | Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,38A,220V AC coil,50Hz,1NO auxiliary contact

Schneider LC1E3810M5 Contactor: A Detailed Guide

Introduction

it is a versatile and reliable contactor designed to manage high-performance electrical circuits. Suitable for industrial and commercial use, it ensures smooth operations for motor control and power distribution applications. With its robust design and compliance with international standards, the LC1E3810M5 is a trusted choice for professionals seeking efficiency and safety.

Key Features

  • Rated Current: Handles up to 38A, suitable for medium-duty electrical loads.
  • Coil Voltage: Operates at 220V AC, ensuring compatibility with standard supply voltages.
  • Auxiliary Contact Configuration: Includes one normally open (NO) auxiliary contact for added control flexibility.
  • Durable Build: Constructed to perform reliably in challenging environments.
  • Compact Design: Optimized for space-saving integration in control panels.

Technical Specifications

  • Product Type: Power Contactor
  • Model Number: LC1E3810M5
  • Rated Operational Current: 38A
  • Control Voltage: 220V AC
  • Auxiliary Contacts: 1 NO
  • Utilization Category: AC-3
  • Compliance: Meets IEC 60947-4-1 standards

Applications

it supports a wide range of industrial applications:

  1. Motor Control: Suitable for controlling motors up to 18.5 kW (at 400V).
  2. Lighting Circuits: Used in medium-scale lighting systems.
  3. Heating and Ventilation: Controls resistive and inductive loads in HVAC systems.
  4. Power Management: Facilitates efficient load switching in distribution panels.

Benefits

  • Efficiency: Optimized for minimal power loss and energy savings.
  • Reliability: Designed for consistent performance under demanding conditions.
  • Ease of Installation: Features user-friendly terminals and a clear layout for quick setup.
  • Safety Features: Equipped with protective mechanisms against overheating and overcurrent.

Maintenance Tips

To maximize the lifespan and efficiency of it

  1. Inspect Regularly: Monitor contacts and terminals for wear.
  2. Tighten Connections: Ensure that all electrical connections are secure.
  3. Clean Periodically: Remove dust and debris from the device and its surroundings.
  4. Replace When Needed: Change worn-out components promptly to maintain safety.

Conclusion

it contactor is an excellent solution for medium-duty motor control and power management applications. With its advanced design, high reliability, and user-friendly features, it is a valuable asset for industrial operations.

Choosing it ensures efficient performance and long-term reliability, making it a worthwhile investment for professionals seeking high-quality electrical solutions.

Main
RangeEasy TeSys
range of productEasy TeSys Control
product or component typeContactor
Device short nameLC1E
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
Poles description3P
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current38 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
38 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
50 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage220 V AC 50 Hz
Complementary
Motor power kW18.5 kW at 500 V
18.5 kW at 660…690 V
9 kW at 220…230 V AC 50/60 Hz
18.5 kW at 380…400 V
18.5 kW at 415 V
18.5 kW at 440 V
Pole contact composition3 NO
[Ith] conventional free air thermal current50 A (at 55 °C) for power circuit
Irms rated making capacity380 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity304 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current60 A 40 °C – 600 s for power circuit
310 A 40 °C – 10 s for power circuit
150 A 40 °C – 60 s for power circuit
Associated fuse rating10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
Average impedance2.5 mOhm – Ith 50 A 50 Hz for power circuit
Power dissipation per pole2.9 W AC-3
5 W AC-1
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Overvoltage categoryIII
Pollution degree3
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability8000000 cycles
Electrical durability350000 cycles AC-1
900000 cycles AC-3
Control circuit typeAC at 50 Hz
Control circuit voltage limits0.85…1.1 Uc (-5…55 °C):operational 50 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA8.3 VA 50 Hz cos phi 0.3 (at 20 °C)
8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation2…3 W for control circuit
Operating time12…22 ms on closing
4…19 ms on opening
Maximum operating rate1800 cyc/h 60 °C
Connections – terminalsControl circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 1…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 2.1 N.m
Auxiliary contact composition1 NO
Minimum switching voltage17 V for control circuit
Minimum switching current5 mA for control circuit
Insulation resistance> 10 MOhm for control circuit
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
mounting supportPlate
DIN rail
Environment
StandardsIEC 60947-4-1
IEC 60947-5-1
IEC 60947-1
Product certificationsEAC
CE
IP degree of protectionIP2X conforming to IEC 60529
Protective treatmentTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Permissible ambient air temperature around the device-20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude3000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Mechanical robustnessVibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height84 mm
Width56 mm
Depth86 mm
net weight0.45 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.800 cm
Package 1 Width8.500 cm
Package 1 Length9.300 cm
Package 1 Weight445.000 g
Unit Type of Package 2S02
Number of Units in Package 224
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight11.008 kg
Contractual warranty
Warranty18 months

Main documents

DatasheetDownload Datasheet
Product datasheetLC1E3810M5 
Instruction sheet
Download
CatalogDownload
Environmental disclosure
Download
CAD FilesDownload

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1E3810M5 | Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,38A,220V AC coil,50Hz,1NO auxiliary contact”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat