1. Technical Specifications

  • Model: LC1F185M7

  • Series: TeSys F

  • Contactor Type: 3-pole (3 Normally Open contacts – 3NO)

  • Utilization Category: AC-3

  • Rated Operational Voltage: Up to 440V AC

  • Rated Operational Current (AC-3): 185A

  • Power Rating: Up to 90 kW (at 400V AC, 3-phase motors)

  • Coil Voltage: 220V AC

  • Coil Frequency: 50/60Hz

  • Auxiliary Contacts: Auxiliary blocks available separately

  • Mounting Options: Panel mounting with screw fixing

  • Mechanical Durability: Up to 5 million operations

  • Electrical Durability: Approx. 1 million operations (depending on load)

  • Standards Compliance: IEC 60947-4-1

2. Key Features

High Power Capacity

With a 185A current rating, this contactor is designed for large motors and high-load switching, providing robust and stable performance.

Heavy-Duty Construction

Engineered for harsh industrial conditions, the TeSys F series contactors are known for their rugged design and long operational life.

Reliable Coil Operation

Equipped with a 220V AC coil that supports both 50Hz and 60Hz frequencies, offering compatibility across multiple regions and power systems.

Expandability

Supports the addition of auxiliary contact blocks, timers, and mechanical interlocks, allowing for greater customization in control schemes.

Thermal and Magnetic Coordination

Designed to work seamlessly with Schneider thermal overload relays and circuit breakers for complete motor protection systems.

3. Typical Applications

  • Large Industrial Motors: Ideal for motors up to 90 kW (at 400V) used in heavy machinery.

  • Pumping Stations: Water treatment, irrigation, and industrial pumping systems.

  • Compressors and Fans: High-capacity HVAC equipment and industrial ventilation.

  • Crane and Hoist Control: Reliable control for large motors in lifting systems.

  • Industrial Automation: Main contactor in control panels for production lines.

  • Power Distribution Systems: Switching and protection in industrial low-voltage switchboards.

SKU: LC1F185M7 Category: Brand:
brands

Main
Range TeSys
Range of product TeSys F
Product or component type Contactor
Device short name LC1F
contactor application Motor control
Resistive load
Utilisation category AC-3
AC-4
AC-1
poles description 3P
[Ue] rated operational voltage <= 460 V DC
<= 690 V AC 50/60 Hz
[Uc] control circuit voltage 220 V AC 40…400 Hz
[Ie] rated operational current 275 A (at <40 °C) at <= 440 V AC-1
185 A (at <55 °C) at <= 440 V AC-3
Complementary
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 275 A (at 40 °C)
Rated breaking capacity 1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 1500 A 40 °C – 10 s
920 A 40 °C – 30 s
740 A 40 °C – 1 min
500 A 40 °C – 3 min
400 A 40 °C – 10 min
Associated fuse rating 200 A aM at <= 440 V
315 A gG at <= 440 V
Average impedance 0.33 mOhm – Ith 275 A 50 Hz
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole 12 W AC-3
25 W AC-1
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 90 kW at 380…400 V AC 50/60 Hz (AC-3)
100 kW at 415 V AC 50/60 Hz (AC-3)
100 kW at 440 V AC 50/60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 660…690 V AC 50/60 Hz (AC-3)
55 kW at 220…230 V AC 50/60 Hz (AC-3)
33 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits Operational: 0.85…1.1 Uc 40…400 Hz (at 55 °C)
Drop-out: 0.2…0.55 Uc 40…400 Hz (at 55 °C)
Mechanical durability 10 Mcycles
Inrush power in VA 1070 VA, 40…400 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA 9.9 VA, 40…400 Hz cos phi 0.9 (at 20 °C)
Maximum operating rate 2400 cyc/h 55 °C
Operating time 35 ms closing (at Uc)
130 ms opening (at Uc)
Connections – terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) – busbar cross section: 25 x 3 mm
Power circuit: lugs-ring terminals 1 cable(s) 150 mm²
Power circuit: connector 1 cable(s) 150 mm²
Power circuit: bolted connection
Tightening torque Control circuit: 1.2 N.m
Power circuit: 18 N.m
mounting support Plate
Heat dissipation 8…9.8 W
motor power range 30…50 kW at 200…240 V 3 phases
55…100 kW at 200…240 V 3 phases
55…100 kW at 380…440 V 3 phases
55…100 kW at 480…500 V 3 phases
110…220 kW at 480…500 V 3 phases
Motor starter type Direct on-line contactor
Contactor coil voltage 220 V AC standard
Standards IEC 60947-4-1
JIS C8201-4-1
EN 60947-4-1
IEC 60947-1
EN 60947-1
Product certifications LROS (Lloyds register of shipping)
RMRoS
UL
BV
RINA
CSA
DNV
ABS
CB
UKCA
Compatibility code LC1F
Control circuit type AC at 40…400 Hz
Environment
IP degree of protection IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Protective treatment TH
Ambient air temperature for operation -5…55 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the device -40…70 °C
Height 174 mm
Width 168.5 mm
Depth 181 mm
Operating altitude 3000 m without derating
Net weight 4.65 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 21.000 cm
Package 1 Width 22.000 cm
Package 1 Length 23.600 cm
Package 1 Weight 4.900 kg
Unit Type of Package 2 P06
Number of Units in Package 2 12
Package 2 Height 80.000 cm
Package 2 Width 80.000 cm
Package 2 Length 60.000 cm
Package 2 Weight 67.084 kg
Contractual warranty
Warranty 18 months
Main
Range TeSys
Range of product TeSys F
Product or component type Contactor
Device short name LC1F
contactor application Motor control Resistive load
Utilisation category AC-3 AC-4 AC-1
poles description 3P
[Ue] rated operational voltage <= 460 V DC <= 690 V AC 50/60 Hz
[Uc] control circuit voltage 220 V AC 40...400 Hz
[Ie] rated operational current 275 A (at <40 °C) at <= 440 V AC-1 185 A (at <55 °C) at <= 440 V AC-3
Complementary
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 275 A (at 40 °C)
Rated breaking capacity 1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 1500 A 40 °C - 10 s 920 A 40 °C - 30 s 740 A 40 °C - 1 min 500 A 40 °C - 3 min 400 A 40 °C - 10 min
Associated fuse rating 200 A aM at <= 440 V 315 A gG at <= 440 V
Average impedance 0.33 mOhm - Ith 275 A 50 Hz
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Power dissipation per pole 12 W AC-3 25 W AC-1
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 90 kW at 380...400 V AC 50/60 Hz (AC-3) 100 kW at 415 V AC 50/60 Hz (AC-3) 100 kW at 440 V AC 50/60 Hz (AC-3) 110 kW at 500 V AC 50/60 Hz (AC-3) 110 kW at 660...690 V AC 50/60 Hz (AC-3) 55 kW at 220...230 V AC 50/60 Hz (AC-3) 33 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
Mechanical durability 10 Mcycles
Inrush power in VA 1070 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA 9.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Maximum operating rate 2400 cyc/h 55 °C
Operating time 35 ms closing (at Uc) 130 ms opening (at Uc)
Connections - terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 150 mm² Power circuit: connector 1 cable(s) 150 mm² Power circuit: bolted connection
Tightening torque Control circuit: 1.2 N.m Power circuit: 18 N.m
mounting support Plate
Heat dissipation 8…9.8 W
motor power range 30…50 kW at 200…240 V 3 phases 55…100 kW at 200…240 V 3 phases 55…100 kW at 380…440 V 3 phases 55…100 kW at 480…500 V 3 phases 110…220 kW at 480…500 V 3 phases
Motor starter type Direct on-line contactor
Contactor coil voltage 220 V AC standard
Standards IEC 60947-4-1 JIS C8201-4-1 EN 60947-4-1 IEC 60947-1 EN 60947-1
Product certifications LROS (Lloyds register of shipping) RMRoS UL BV RINA CSA DNV ABS CB UKCA
Compatibility code LC1F
Control circuit type AC at 40...400 Hz
Environment
IP degree of protection IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Protective treatment TH
Ambient air temperature for operation -5…55 °C
Ambient air temperature for storage -60…80 °C
Permissible ambient air temperature around the device -40…70 °C
Height 174 mm
Width 168.5 mm
Depth 181 mm
Operating altitude 3000 m without derating
Net weight 4.65 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 21.000 cm
Package 1 Width 22.000 cm
Package 1 Length 23.600 cm
Package 1 Weight 4.900 kg
Unit Type of Package 2 P06
Number of Units in Package 2 12
Package 2 Height 80.000 cm
Package 2 Width 80.000 cm
Package 2 Length 60.000 cm
Package 2 Weight 67.084 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1F185M7 | TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 185 A – coil 220 V AC”

There are no reviews yet.

SHOPPING CART

close