Schneider LC1G150KUEN Contactor: Comprehensive Guide

Introduction

In the realm of electrical systems, contactors play a pivotal role. it is a robust and reliable component that facilitates the control of electrical power circuits. But what makes it stand out, and why is it essential for modern electrical systems?

Understanding the Basics

Overview of the Schneider LC1G150KUEN Contactor

it is an industrial-grade contactor designed to manage and control high-power circuits. It is commonly used to switch electrical loads in various applications, from industrial machinery to power distribution systems.

Key Features and Specifications

Key features of the LC1G150KUEN include:

  • High current rating of up to 150A, suitable for heavy-duty applications.
  • AC and DC coil compatibility, providing versatility in different setups.
  • Durable construction that ensures long operational life.
  • Enhanced safety features, including arc suppression and overload protection.

Design and Build

Physical Characteristics

The LC1G150KUEN boasts a compact yet sturdy design, allowing it to be installed in various enclosures without taking up excessive space. Its robust housing protects internal components from dust, moisture, and mechanical damage.

Materials Used

Constructed with high-quality, durable materials, the LC1G150KUEN is built to withstand harsh industrial environments. The contact points are made of silver alloys, ensuring efficient conductivity and resistance to wear and tear.

Compatibility with Other Equipment

This contactor is designed to integrate seamlessly with other Schneider Electric products and various third-party devices, making it a flexible choice for diverse electrical setups.

Installation Process

Pre-Installation Requirements

Before installing the LC1G150KUEN, ensure you have all necessary components, including compatible mounting brackets, screws, and the appropriate tools. Verify that your power supply and control circuits meet the specifications of the contactor.

Step-by-Step Installation Guide
  1. Mount the contactor securely in your control panel or designated enclosure.
  2. Connect the main power terminals according to the wiring diagram provided by Schneider.
  3. Wire the control circuit to the coil terminals, ensuring correct voltage and polarity.
  4. Tighten all connections and double-check for any loose wires or potential short circuits.
  5. Power up the system and perform a test operation to ensure the contactor is functioning correctly.
Safety Precautions

Always follow safety guidelines when working with electrical equipment. This includes wearing appropriate protective gear, ensuring the power is off before making connections, and following lockout/tagout procedures.

Configuration and Setup

Initial Setup Steps

After installation, the contactor needs to be configured for your specific application. This involves setting the control parameters, such as voltage thresholds and timing sequences.

Using Schneider Software for Configuration

Schneider offers software tools that simplify the configuration process. These tools provide a user-friendly interface to adjust settings and monitor the contactor’s performance in real-time.

Troubleshooting Configuration Issues

If you encounter any issues during setup, refer to the user manual or Schneider’s online resources. Common problems can often be resolved by recalibrating settings or updating the software.

Operational Capabilities

Switching Performance

The LC1G150KUEN excels in high-speed switching, providing reliable control over electrical circuits with minimal response time. This ensures smooth operation of connected equipment and reduces downtime.

Load Capacity

With a high load capacity of up to 150A, this contactor is capable of handling significant electrical loads, making it suitable for heavy-duty applications in various industries.

Durability and Lifespan

Designed for long-term use, the LC1G150KUEN offers excellent durability. Its robust construction and high-quality materials ensure it can withstand frequent operation and harsh environmental conditions.

Integration with Electrical Systems

Connecting to Control Circuits

The LC1G150KUEN can be easily integrated into control circuits, allowing for automated and remote operation. This integration enhances system efficiency and reliability.

Network Integration

The contactor supports various communication protocols, facilitating seamless integration into existing network infrastructures. This allows for centralized control and monitoring of multiple contactors across a facility.

Communication Protocols Supported

Supporting protocols like Modbus and Ethernet, the LC1G150KUEN ensures compatibility with a wide range of control systems and devices.

Applications in Various Industries

Manufacturing and Industrial Automation

In manufacturing, the LC1G150KUEN controls machinery and production lines, ensuring efficient and reliable operation.

Energy and Power Management

For energy management systems, this contactor helps in managing power distribution and controlling load shedding, optimizing energy usage.

Transportation Infrastructure

In transportation, the LC1G150KUEN is used to control electrical systems in trains, trams, and other vehicles, ensuring safe and efficient operation.

SKU: LC1G150KUEN Categories: ,
Main
Range TeSys
Range of product TeSys Giga
Product or component type Contactor
Device short name LC1G
contactor application Power switching
Motor control
utilisation category AC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8a
AC-8b
DC-1
DC-3
DC-5
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current 275 A (at <40 °C) at <= 1000 V AC-1
150 A (at <60 °C) at <= 440 V AC-3
[Uc] control circuit voltage 100…250 V AC 50/60 Hz
100…250 V DC
Control circuit voltage limits Operational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
Complementary
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 275 A (at 40 °C)
Rated breaking capacity 1280 A at 440 V
[Icw] rated short-time withstand current 1.2 kA – 10 s
0.7 kA – 30 s
0.6 kA – 1 min
0.45 kA – 3 min
0.35 kA – 10 min
Associated fuse rating 160 A aM at <= 440 V for motor
160 A aM at <= 690 V for motor
315 A gG at <= 690 V
Average impedance 0.00018 Ohm
[Ui] rated insulation voltage 1000 V
Power dissipation per pole 10 W AC-1 – Ith 275 A
5 W AC-3 – Ith 150 A
Compatibility code LC1G
Pole contact composition 3 NO
Auxiliary contact composition 1 NO + 1 NC
Motor power kW 37 kW at 230 V AC 50/60 Hz (AC-3e)
75 kW at 400 V AC 50/60 Hz (AC-3e)
75 kW at 415 V AC 50/60 Hz (AC-3e)
90 kW at 440 V AC 50/60 Hz (AC-3e)
90 kW at 500 V AC 50/60 Hz (AC-3e)
90 kW at 690 V AC 50/60 Hz (AC-3e)
75 kW at 1000 V AC 50/60 Hz (AC-3e)
37 kW at 230 V AC 50/60 Hz (AC-3)
75 kW at 400 V AC 50/60 Hz (AC-3)
75 kW at 415 V AC 50/60 Hz (AC-3)
90 kW at 440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
90 kW at 690 V AC 50/60 Hz (AC-3)
75 kW at 1000 V AC 50/60 Hz (AC-3)
37 kW at 230 V AC 50/60 Hz (AC-4)
75 kW at 400 V AC 50/60 Hz (AC-4)
75 kW at 415 V AC 50/60 Hz (AC-4)
80 kW at 440 V AC 50/60 Hz (AC-4)
90 kW at 500 V AC 50/60 Hz (AC-4)
90 kW at 690 V AC 50/60 Hz (AC-4)
75 kW at 1000 V AC 50/60 Hz (AC-4)
Motor power hp 40 hp at 200/208 V 60 Hz
50 hp at 230/240 V 60 Hz
100 hp at 460/480 V 60 Hz
125 hp at 575/600 V 60 Hz
Irms rated making capacity 1890 A at 440 V
Coil technology Built-in bidirectional peak limiting
Mechanical durability 8 Mcycles
inrush power in VA (50/60 Hz, AC) 540 VA
inrush power in W (DC) 380 W
hold-in power consumption in VA (50/60 Hz, AC) 12.4 VA
hold-in power consumption in W (DC) 7.8 W
Operating time 40…70 ms closing
15…50 ms opening
Maximum operating rate 600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4
Connections – terminals Power circuit: bar 2 – busbar cross section: 25 x 6 mm
Power circuit: lugs-ring terminals 1 185 mm²
Power circuit: bolted connection
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch 35 mm
mounting support Plate
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
product certifications CB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque 18 N.m
height 193 mm
Width 108 mm
Depth 193 mm
Net weight 3.6 kg
Environment
IP degree of protection IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -60…80 °C
Mechanical robustness Vibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
Colour Dark grey
Protective treatment TH
Permissible ambient air temperature around the device -40…70 °C at Uc
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 24.5 cm
Package 1 Width 23.5 cm
Package 1 Length 38.5 cm
Package 1 Weight 4.768 kg
Unit Type of Package 2 S06
Number of Units in Package 2 6
Package 2 Height 75 cm
Package 2 Width 60 cm
Package 2 Length 80 cm
Package 2 Weight 38.62 kg

Main Document

Data Sheet : LC1G150KUEN

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1G150KUEN Contactor | High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 150A, standard version, 100…250V wide band AC/DC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024