Let's Chat
-46%
,

Schneider LC1G185KUEN Contactor | High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 185A, standard version, 100…250V wide band AC/DC coil

Schneider Electric
Availability:

Out of stock


Schneider LC1G185KUEN Contactor

31,414 EGP 58,174 EGP

Out of stock

Compare

Schneider LC1G185KUEN Contactor

Introduction

In the realm of electrical systems, contactors play a pivotal role in controlling power circuits. Among the top-tier options available, it stands out for its reliability and advanced features. This article will explore the intricacies of this contactor, discussing its features, benefits, applications, and more to help you understand why it’s a preferred choice in many industrial settings.

Overview of Schneider Electric

History and Background

Schneider Electric has a long-standing reputation for excellence in energy management and automation. Founded in 1836, the company has evolved into a global leader, consistently innovating to meet the dynamic needs of various industries. Schneider Electric’s products are synonymous with quality and efficiency, and it is no exception.

Commitment to Innovation and Sustainability

Schneider Electric is dedicated to driving innovation and promoting sustainability. Through substantial investment in research and development, the company ensures that its products, including it, are at the forefront of technology, offering superior performance while minimizing environmental impact.

Features of the Schneider LC1G185KUEN Contactor

Design and Build Quality

it boasts a robust design that ensures long-lasting performance. Its build quality is engineered to withstand harsh industrial environments, making it a reliable choice for demanding applications. The contactor’s design also incorporates user-friendly elements that simplify installation and maintenance.

Key Specifications

This contactor is designed for high-performance applications, with a rated operational voltage of up to 1000V and a current rating of 185A. It is suitable for both AC and DC circuits, providing versatility across different electrical systems. it also features high electrical and mechanical endurance, ensuring consistent performance over time.

Durability and Reliability

Durability is a key strength of it. Made from high-quality materials, it is built to last, even under extreme conditions. Its reliability minimizes the risk of downtime, which is crucial for maintaining efficient operations in industrial settings.

Benefits of Using Schneider LC1G185KUEN Contactor

Enhanced Performance

it is designed to enhance the performance of electrical systems. Its high current capacity and efficient switching capabilities ensure smooth operation, reducing the likelihood of system failures and improving overall productivity.

Safety and Compliance

Safety is a paramount concern in electrical systems, and it excels in this area. It complies with international safety standards, offering features like thermal overload protection and short-circuit protection. These safety mechanisms protect both the equipment and personnel, making it a secure choice for industrial applications.

Cost-Effectiveness

While the initial investment in it Contactor may be higher than some alternatives, its long-term cost-effectiveness is undeniable. Its durability and reliability reduce maintenance costs and downtime, leading to significant savings over its lifespan.

Applications of Schneider LC1G185KUEN Contactor

Industrial Machinery

In industrial settings, machinery requires reliable control systems to function optimally. it is widely used to control and manage heavy machinery, ensuring efficient and uninterrupted operation.

HVAC Systems

Heating, ventilation, and air conditioning (HVAC) systems benefit from the reliability and performance of the Schneider LC1G185KUEN Contactor. Its ability to handle high currents and voltages makes it ideal for controlling large HVAC units, ensuring consistent climate control.

Energy and Power Distribution

The energy sector relies on robust contactors for power distribution and control. it is used in power plants and distribution networks to manage electrical loads effectively, contributing to stable and efficient power delivery.

Installation and Maintenance

Easy Installation Process

Installing it is straightforward, thanks to its well-designed components and clear instructions. Its modular design allows for easy integration into existing systems, minimizing installation time and effort.

Tips for Effective Maintenance

Maintaining the Schneider LC1G185KUEN Contactor involves regular inspections and timely servicing. Routine checks for signs of wear and tear, along with cleaning and lubrication of moving parts, can extend its lifespan and ensure reliable performance.

Common Issues and Troubleshooting

Common issues with contactors, such as coil failures and contact wear, can affect the performance of the Schneider LC1G185KUEN. Schneider Electric provides comprehensive troubleshooting guides and support services to help users resolve these issues quickly and efficiently.

Comparison with Other Contactors

Key Competitors

The market for contactors includes several key players, such as Siemens, ABB, and Eaton. Each brand offers a range of products with different features and benefits. Comparing these options helps in understanding where the Schneider LC1G185KUEN stands in terms of performance, reliability, and cost.

Pros and Cons

The Schneider LC1G185KUEN Contactor has numerous advantages, including its robust design, high performance, and safety features. However, it may come with a higher initial cost compared to some competitors. Evaluating the pros and cons helps in making an informed decision based on specific needs and budget.

SKU: LC1G185KUEN Categories: ,
Main
Range TeSys
Range of product TeSys Giga
Product or component type Contactor
Device short name LC1G
contactor application Power switching
Motor control
utilisation category AC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8a
AC-8b
DC-1
DC-3
DC-5
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current 305 A (at <40 °C) at <= 1000 V AC-1
185 A (at <60 °C) at <= 440 V AC-3
[Uc] control circuit voltage 100…250 V AC 50/60 Hz
100…250 V DC
Control circuit voltage limits Operational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
Complementary
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 305 A (at 40 °C)
Rated breaking capacity 1610 A at 440 V
[Icw] rated short-time withstand current 1.5 kA – 10 s
0.92 kA – 30 s
0.74 kA – 1 min
0.5 kA – 3 min
0.4 kA – 10 min
Associated fuse rating 200 A aM at <= 440 V for motor
160 A aM at <= 690 V for motor
315 A gG at <= 690 V
Average impedance 0.00017 Ohm
[Ui] rated insulation voltage 1000 V
Power dissipation per pole 20 W AC-1 – Ith 305 A
6 W AC-3 – Ith 185 A
Compatibility code LC1G
Pole contact composition 3 NO
Auxiliary contact composition 1 NO + 1 NC
Motor power kW 55 kW at 230 V AC 50/60 Hz (AC-3e)
90 kW at 400 V AC 50/60 Hz (AC-3e)
90 kW at 415 V AC 50/60 Hz (AC-3e)
110 kW at 440 V AC 50/60 Hz (AC-3e)
110 kW at 500 V AC 50/60 Hz (AC-3e)
110 kW at 690 V AC 50/60 Hz (AC-3e)
75 kW at 1000 V AC 50/60 Hz (AC-3e)
55 kW at 230 V AC 50/60 Hz (AC-3)
90 kW at 400 V AC 50/60 Hz (AC-3)
90 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 690 V AC 50/60 Hz (AC-3)
75 kW at 1000 V AC 50/60 Hz (AC-3)
55 kW at 230 V AC 50/60 Hz (AC-4)
90 kW at 400 V AC 50/60 Hz (AC-4)
90 kW at 415 V AC 50/60 Hz (AC-4)
100 kW at 440 V AC 50/60 Hz (AC-4)
110 kW at 500 V AC 50/60 Hz (AC-4)
110 kW at 690 V AC 50/60 Hz (AC-4)
75 kW at 1000 V AC 50/60 Hz (AC-4)
Motor power hp 50 hp at 200/208 V 60 Hz
60 hp at 230/240 V 60 Hz
125 hp at 460/480 V 60 Hz
150 hp at 575/600 V 60 Hz
Irms rated making capacity 2310 A at 440 V
Coil technology Built-in bidirectional peak limiting
Mechanical durability 8 Mcycles
inrush power in VA (50/60 Hz, AC) 540 VA
inrush power in W (DC) 380 W
hold-in power consumption in VA (50/60 Hz, AC) 12.4 VA
hold-in power consumption in W (DC) 7.8 W
Operating time 40…70 ms closing
15…50 ms opening
Maximum operating rate 600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4
Connections – terminals Power circuit: bar 2 – busbar cross section: 25 x 6 mm
Power circuit: lugs-ring terminals 1 185 mm²
Power circuit: bolted connection
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch 35 mm
mounting support Plate
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
product certifications CB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque 18 N.m
height 193 mm
Width 108 mm
Depth 193 mm
Net weight 3.6 kg
Environment
IP degree of protection IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -60…80 °C
Mechanical robustness Vibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
Colour Dark grey
Protective treatment TH
Permissible ambient air temperature around the device -40…70 °C at Uc
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 23.000 cm
Package 1 Width 24.500 cm
Package 1 Length 38.500 cm
Package 1 Weight 4.766 kg
Unit Type of Package 2 P06
Number of Units in Package 2 6
Package 2 Height 75.000 cm
Package 2 Width 60.000 cm
Package 2 Length 80.000 cm
Package 2 Weight 41.034 kg

Main Document

Data Sheet : LC1G185KUEN 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1G185KUEN Contactor | High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 185A, standard version, 100…250V wide band AC/DC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024