Let's Chat
-46%
,

Schneider LC1K0601B7 | TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NC aux. – 24 V AC coil

Availability:

In stock


Schneider LC1K0601B7 | TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NC aux. – 24 V AC coil

1,332 EGP 2,467 EGP

In stock

Compare

Schneider LC1K0601B7: The Ultimate Guide

In the realm of industrial automation, having the right components is crucial for ensuring seamless operations. The Schneider LC1K0601B7 is one such component that stands out due to its reliability and efficiency. Whether you’re setting up a new system or upgrading an existing one, understanding this product’s intricacies can make all the difference.

What is Schneider LC1K0601B7?

The Schneider LC1K0601B7 is a contactor, a type of electrical relay used for switching an electrical circuit on or off. Designed for controlling electric motors and other high-power loads, this device ensures that industrial operations run smoothly without interruption. It boasts a range of features that cater to various industrial needs, making it a versatile choice for many applications.

Key Features and Specifications

  • Voltage Rating: Up to 690V
  • Current Rating: 6A
  • Contact Configuration: 1 NO (Normally Open)
  • Coil Voltage: 230V AC
  • Operational Temperature Range: -5°C to 60°C

These specifications underline the LC1K0601B7’s ability to handle demanding tasks while maintaining high performance.

Design and Build Quality

When it comes to industrial components, durability is non-negotiable. The Schneider LC1K0601B7 is constructed from high-quality materials that withstand harsh conditions. Its compact size and lightweight design make it easy to install in various setups without compromising on performance.

Electrical Characteristics

Understanding the electrical characteristics of the Schneider LC1K0601B7 is essential for optimal application. This contactor supports:

  • Voltage Ratings: Suitable for a wide range of voltages up to 690V, making it adaptable for different systems.
  • Current Ratings: With a current rating of 6A, it can handle substantial loads efficiently.
  • Contact Ratings: The 1 NO contact configuration ensures reliable switching for various electrical circuits.

Applications of Schneider LC1K0601B7

Industrial Automation

In automated systems, the Schneider LC1K0601B7 acts as a key player in controlling machinery, ensuring that operations are executed precisely.

Motor Control

It’s extensively used in motor control applications, providing reliable performance in starting and stopping electric motors.

Other Relevant Applications

From lighting systems to heating equipment, the Schneider LC1K0601B7’s versatility makes it a valuable component in various industrial setups.

Installation Process

Installing the Schneider LC1K0601B7 involves several steps to ensure safety and efficiency.

Pre-installation Requirements

  • Ensure Power is Off: Always start with turning off the power supply to avoid electrical hazards.
  • Check Compatibility: Verify that the contactor matches the system’s voltage and current requirements.

Step-by-Step Installation Guide

  1. Mount the Contactor: Securely mount the contactor in the designated location.
  2. Connect the Coils: Attach the coil connections according to the manufacturer’s instructions.
  3. Wire the Contacts: Connect the load wires to the contact points.
  4. Test the Installation: Once connected, test the contactor to ensure it operates correctly.

Safety Precautions

  • Use Proper Tools: Ensure you use insulated tools to prevent electrical shocks.
  • Follow Manufacturer Guidelines: Adhering to the manufacturer’s installation guidelines is crucial for safety and performance.

Performance and Efficiency

The Schneider LC1K0601B7 is known for its operational efficiency and consistent performance. It operates effectively under various conditions, making it a reliable choice for demanding industrial applications. Its longevity and reliability are backed by numerous user testimonials and case studies.

SKU: LC1K0601B7 Categories: ,
Main
Range TeSys
Product or component type Contactor
Device short name LC1K
Device application Control
contactor application Motor control
Complementary
Utilisation category AC-3
AC-3e
AC-4
poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current 6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 24 V AC 50/60 Hz
Motor power kW 1.5 kW at 220…230 V AC 50/60 Hz AC-3
2.2 kW at 380…415 V AC 50/60 Hz AC-3
3 kW at 440/690 V AC 50/60 Hz AC-3
1.5 kW at 220…230 V AC 50/60 Hz AC-3e
2.2 kW at 380…415 V AC 50/60 Hz AC-3e
3 kW at 440/690 V AC 50/60 Hz AC-3e
1.5 kW at 220…230 V AC 50/60 Hz AC-4
2.2 kW at 380…415 V AC 50/60 Hz AC-4
3 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition 1 NC
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity 110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A 50 °C – 1 s for power circuit
85 A 50 °C – 5 s for power circuit
80 A 50 °C – 10 s for power circuit
60 A 50 °C – 30 s for power circuit
45 A 50 °C – 1 min for power circuit
40 A 50 °C – 3 min for power circuit
20 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA 30 VA (at 20 °C)
Hold-in power consumption in VA 4.5 VA (at 20 °C)
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8…1.15 Uc (at <50 °C) Drop-out: >= 0.20 Uc (at <50 °C)
Connections – terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate 3600 cyc/h
Auxiliary contacts type type instantaneous 1 NC
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Mounting support Plate
Rail
Tightening torque 0.8…1.3 N.m – on screw clamp terminals Philips No 2
0.8…1.3 N.m – on screw clamp terminals flat Ø 6 mm
Power circuit: 0.8…1.3 N.m – on lugs-ring terminals pozidriv No 2
Operating time 10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance 0.5 mm
Mechanical durability 10 Mcycles
Electrical durability 1.3 Mcycles 6 A AC-3 at Ue <= 440 V
1.3 Mcycles 6 A AC-3e at Ue <= 440 V
0.05 Mcycles 36 A AC-4 at Ue <= 440 V
Mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Height 58 mm
Width 45 mm
Depth 57 mm
Net weight 0.18 kg
Environment
Standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protection IP2X conforming to VDE 0106
Protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
Ambient air temperature for storage -50…80 °C
Operating altitude 2000 m without derating
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.800 cm
Package 1 Width 6.200 cm
Package 1 Length 6.500 cm
Package 1 Weight 178.900 g
Unit Type of Package 2 S02
Number of Units in Package 2 50
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.207 kg
Unit Type of Package 3 P06
Number of Units in Package 3 800
Package 3 Height 75.000 cm
Package 3 Width 80.000 cm
Package 3 Length 60.000 cm
Package 3 Weight 155.306 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1K0601B7 | TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NC aux. – 24 V AC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024