Schneider LC1K0610B7 | Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 24VAC coil

Availability:

In stock


1,283 EGP 2,467 EGP

In stock

Compare

Schneider  LC1K0610B7 | Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 24VAC coil

Schneider LC1K0610B7 Description

Schneider LC1K0610B7 is a renowned electrical contactor manufactured by Schneider Electric, a global leader in energy management and automation solutions. This compact yet powerful contactor is designed to meet the demanding requirements of various industrial and commercial applications.

Introduction to Schneider LC1K0610B7

Schneider LC1K0610B7 is part of the TeSys K series, known for its reliability and performance. It is specifically engineered to control motors and other electrical loads with ease, making it an ideal choice for a wide range of applications.

Key Features of Schneider LC1K0610B7

Compact Design

One of the standout features of Schneider LC1K0610B7 is its compact design, allowing for easy integration into control panels and enclosures with limited space. This space-saving design makes it suitable for both new installations and retrofit projects.

High Performance

Despite its small size, Schneider LC1K0610B7 delivers high performance, ensuring efficient operation and reliable control of electrical loads. With its robust construction and advanced technology, it offers long-term durability and stability.

Applications of Schneider LC1K0610B7

Schneider LC1K0610B7 finds applications across various industries, including:

Industrial Automation

In industrial settings, Schneider LC1K0610B7 is commonly used for motor control in manufacturing processes, conveyor systems, and automated machinery. Its reliable performance and precise control make it indispensable in optimizing production workflows.

HVAC Systems

In commercial buildings and residential complexes, Schneider LC1K0610B7 plays a vital role in HVAC (Heating, Ventilation, and Air Conditioning) systems. It helps regulate the operation of fans, compressors, and pumps, ensuring efficient heating and cooling.

Installation Guide for Schneider LC1K0610B7

Installing Schneider LC1K0610B7 is straightforward, but it requires careful attention to ensure proper functionality. Here are some essential installation steps:

Mounting Instructions

Before installing the contactor, ensure that the mounting surface is clean and free of any debris. Use appropriate screws and fasteners to securely mount the contactor in place.

Wiring Procedure

Follow the wiring diagram provided by Schneider Electric to connect the power supply, control circuits, and load connections to the contactor. Make sure to use compatible cables and connectors for reliable operation.

Maintenance Tips for Schneider LC1K0610B7

To ensure optimal performance and longevity, follow these maintenance tips:

Regular Inspections

Periodically inspect the contactor for signs of wear, corrosion, or damage. Replace any worn-out components and tighten loose connections to prevent electrical faults.

Cleaning Recommendations

Keep the contactor clean and free of dust and debris by gently wiping it with a dry or slightly damp cloth. Avoid using abrasive cleaners or solvents that may damage the surface.

Troubleshooting Common Issues with Schneider LC1K0610B7

Despite its reliability, Schneider LC1K0610B7 may encounter occasional issues. Here are some common problems and troubleshooting tips:

Overheating Problems

If the contactor overheats, check for excessive current flow or poor ventilation. Ensure proper cooling and ventilation around the contactor to prevent overheating.

Electrical Malfunctions

If the contactor fails to engage or disengage properly, check for loose connections or faulty control circuits. Inspect the wiring and connections carefully and tighten or replace as needed.

Comparison with Other Schneider Electric Products

Schneider LC1K0610B7 stands out among other Schneider Electric contactors due to its compact size, high performance, and versatile applications. Compared to similar models, it offers superior efficiency and reliability, making it a preferred choice for many professionals.

Customer Reviews and Feedback on Schneider LC1K0610B7

Customers who have used Schneider LC1K0610B7 praise its reliability, compact design, and ease of installation. Many users appreciate its seamless integration with existing systems and its ability to withstand harsh operating conditions.

Conclusion

In conclusion, Schneider LC1K0610B7 is a versatile and reliable electrical contactor that offers high performance and durability. Its compact design, advanced features, and ease of installation make it an ideal choice for various industrial and commercial applications.

FAQs

  1. Is Schneider LC1K0610B7 suitable for outdoor installations? Yes, Schneider LC1K0610B7 is designed to withstand outdoor environments with proper protection against moisture and dust.
  2. Can Schneider LC1K0610B7 be used with different voltage ratings? Yes, Schneider LC1K0610B7 is available in various voltage ratings to accommodate different electrical systems and requirements.
  3. Does Schneider LC1K0610B7 come with overload protection? Yes, Schneider LC1K0610B7 features built-in overload protection to safeguard connected equipment and prevent damage due to excessive current.
  4. What is the warranty period for Schneider LC1K0610B7? Schneider LC1K0610B7 typically comes with a standard warranty of one year from the date of purchase, covering manufacturing defects and malfunctions.
  5. Is professional installation recommended for Schneider LC1K0610B7? While Schneider LC1K0610B7 can be installed by experienced individuals, professional installation is recommended to ensure proper setup and compliance with safety standards.

SKU: LC1K0610B7 Categories: ,
Weight 0.18 kg
brands

Schneider Electric

Main
Range TeSys
Product or Component Type Contactor
Device short name LC1K
Device Application Control
contactor application Motor control
Complementary
utilisation category AC-3
AC-3e
AC-4
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit <= 690 V AC <= 400 Hz
Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 24 V AC 50/60 Hz
Motor power kW 1.5 kW 220…230 V AC 50/60 Hz AC-3
2.2 kW 380…415 V AC 50/60 Hz AC-3
3 kW 440/690 V AC 50/60 Hz AC-3
1.5 kW 220…230 V AC 50/60 Hz AC-3e
2.2 kW 380…415 V AC 50/60 Hz AC-3e
3 kW 440/690 V AC 50/60 Hz AC-3e
1.5 kW 220…230 V AC 50/60 Hz AC-4
2.2 kW 380…415 V AC 50/60 Hz AC-4
3 kW 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 140 °F (60 °C)) for power circuit
10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity 110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A 122 °F (50 °C) – 1 s for power circuit
85 A 122 °F (50 °C) – 5 s for power circuit
80 A 122 °F (50 °C) – 10 s for power circuit
60 A 122 °F (50 °C) – 30 s for power circuit
45 A 122 °F (50 °C) – 1 min for power circuit
40 A 122 °F (50 °C) – 3 min for power circuit
20 A 122 °F (50 °C) – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit 600 V UL 508
Power circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-5-1
Signalling circuit 600 V UL 508
Power circuit 600 V CSA C22.2 No 14
Signalling circuit 600 V CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA 30 VA (at 68 °F (20 °C))
Hold-in power consumption in VA 4.5 VA (at 68 °F (20 °C))
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8…1.15 Uc (at <122 °F (50 °C)) Drop-out: >= 0.20 Uc (at <122 °F (50 °C))
Connections – terminals Screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid
screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end
screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid
screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end
Maximum operating rate 3600 cyc/h
Auxiliary contacts type Instantaneous 1 NO
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Mounting Support Rail
Plate
Tightening torque 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2
11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm
11.51 lbf.in (1.3 N.m) lugs-ring terminals pozidriv No 2
Operating time 10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Non overlap distance 0.02 in (0.5 mm)
Mechanical durability 10 Mcycles
Electrical durability 1.3 Mcycles 6 A AC-3 <= 440 V
1.3 Mcycles 6 A AC-3e <= 440 V
0.05 Mcycles 36 A AC-4 <= 440 V
Mechanical robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27
Vibrations contactor closed4 Gn, 5…300 Hz IEC 60068-2-6
Vibrations contactor opened2 Gn, 5…300 Hz IEC 60068-2-6
Height 2.28 in (58 mm)
Width 1.77 in (45 mm)
Depth 2.24 in (57 mm)
Net Weight 0.40 lb(US) (0.18 kg)
Environment
Standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product Certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protection IP2X VDE 0106
Protective treatment TC IEC 60068
TC DIN 50016
Ambient Air Temperature for Storage -58…176 °F (-50…80 °C)
Operating altitude 6561.68 ft (2000 m) without derating
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Ordering and shipping details
Category US10I1222326
Discount Schedule 0I12
GTIN 3389110365139
Returnability Yes
Country of origin FR
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 1.97 in (5.000 cm)
Package 1 Width 2.36 in (6.000 cm)
Package 1 Length 2.56 in (6.500 cm)
Package 1 Weight 6.28 oz (178.000 g)
Unit Type of Package 2 S02
Number of Units in Package 2 50
Package 2 Height 5.91 in (15.000 cm)
Package 2 Width 11.81 in (30.000 cm)
Package 2 Length 15.75 in (40.000 cm)
Package 2 Weight 20.16 lb(US) (9.143 kg)
Unit Type of Package 3 P06
Number of Units in Package 3 800
Package 3 Height 29.53 in (75.000 cm)
Package 3 Width 31.50 in (80.000 cm)
Package 3 Length 23.62 in (60.000 cm)
Package 3 Weight 340.15 lb(US) (154.288 kg)
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LC1K0610B7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1K0610B7 | Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO aux., 24VAC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024