-46%
,

Schneider LC1K0610M7 | TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NO aux. – 220…230 V AC coil

Availability:

Out of stock


1,332 EGP 2,467 EGP

Out of stock

Compare

Schneider LC1K0610M7 | TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NO aux. – 220…230 V AC coil

Schneider LC1K0610M7: Unveiling the Power of Efficiency

In today’s rapidly advancing technological landscape, the demand for efficient electrical components is more pronounced than ever. Among the myriad offerings, the Schneider LC1K0610M7 emerges as a stalwart, embodying reliability, performance, and versatility. This article delves into the intricacies of Schneider LC1K0610M7, exploring its features, applications, installation process, maintenance guidelines, and more.

Key Features of Schneider LC1K0610M7

Schneider LC1K0610M7 boasts a plethora of features designed to streamline operations and enhance efficiency.

1. Robust Construction

Crafted with precision engineering, the Schneider LC1K0610M7 exhibits robust construction, ensuring durability and longevity even in demanding environments.

2. High Performance

Equipped with cutting-edge technology, the Schneider LC1K0610M7 delivers high performance, facilitating seamless operation across various applications.

3. Compact Design

Despite its formidable capabilities, the Schneider LC1K0610M7 sports a compact design, optimizing space utilization and simplifying installation.

4. Enhanced Safety Features

Safety remains paramount, and the Schneider LC1K0610M7 prioritizes this aspect with its comprehensive array of safety features, mitigating risks and ensuring peace of mind.

Applications of Schneider LC1K0610M7

The versatility of Schneider LC1K0610M7 extends to a wide array of applications, catering to diverse industrial and commercial needs.

1. Industrial Automation

In industrial settings, the Schneider LC1K0610M7 finds extensive use in motor control applications, facilitating precise control and efficient operation of machinery.

2. HVAC Systems

The Schneider LC1K0610M7 integrates seamlessly into HVAC (Heating, Ventilation, and Air Conditioning) systems, regulating power distribution and optimizing energy efficiency.

3. Building Management Systems

For building management applications, the Schneider LC1K0610M7 serves as a cornerstone, enabling centralized control and monitoring of electrical systems for enhanced efficiency and sustainability.

Installation Guide

Installing the Schneider LC1K0610M7 is a straightforward process, provided the following steps are meticulously followed:

  1. Prepare the Installation Site: Ensure the installation site is clean, dry, and free from any obstructions.
  2. Mounting: Securely mount the Schneider LC1K0610M7 on a stable surface using appropriate mounting hardware.
  3. Wiring: Connect the necessary wires according to the provided wiring diagram, ensuring proper polarity and connections.
  4. Testing: After installation, perform thorough testing to verify proper functionality and address any issues promptly.

Troubleshooting Common Issues

Despite its reliability, occasional issues may arise with the Schneider LC1K0610M7. Here are some common troubleshooting steps:

  1. Overheating: Ensure proper ventilation and cooling mechanisms are in place to prevent overheating.
  2. Electrical Faults: Check for loose connections or damaged wiring and rectify as necessary.
  3. Programming Errors: Review the programming settings and adjust as needed to correct any errors.

Comparison with Similar Products

In comparison to similar products in the market, the Schneider LC1K0610M7 stands out due to its unparalleled combination of features, performance, and reliability.

Maintenance Tips

To ensure optimal performance and longevity, adhering to proper maintenance practices is imperative:

  1. Regular Inspection: Conduct periodic inspections to check for signs of wear or damage.
  2. Cleaning: Keep the Schneider LC1K0610M7 clean and free from dust or debris accumulation.
  3. Scheduled Maintenance: Follow manufacturer-recommended maintenance schedules for proactive upkeep.

Customer Reviews

Customer feedback serves as a testament to the excellence of Schneider LC1K0610M7:

  • “Impressed by the performance and reliability of Schneider LC1K0610M7. A definite game-changer for our industrial operations.”
  • “Easy installation and seamless integration into our HVAC system. Highly recommended!”
  • “The safety features of Schneider LC1K0610M7 provide peace of mind, knowing our electrical systems are in good hands.”

FAQs

  1. Is the Schneider LC1K0610M7 suitable for outdoor applications?
    • Yes, the Schneider LC1K0610M7 is designed to withstand a wide range of environmental conditions, making it suitable for outdoor use.
  2. What is the warranty period for Schneider LC1K0610M7?
    • The Schneider LC1K0610M7 typically comes with a standard warranty period of [insert warranty period].
  3. Can the Schneider LC1K0610M7 be integrated with third-party automation systems?
    • Yes, the Schneider LC1K0610M7 supports integration with various third-party automation systems for enhanced compatibility and flexibility.
  4. What is the maximum operating voltage of Schneider LC1K0610M7?
    • The maximum operating voltage of Schneider LC1K0610M7 is [insert maximum operating voltage].
  5. Does Schneider LC1K0610M7 support remote monitoring and control?
    • Yes, the Schneider LC1K0610M7 offers remote monitoring and control capabilities, enabling convenient management of electrical systems from anywhere.

Conclusion

In conclusion, the Schneider LC1K0610M7 emerges as a versatile and reliable solution for various industrial and commercial applications. With its robust construction, advanced features, and ease of installation, it stands as a testament to Schneider’s commitment to innovation and quality. Embrace the power of efficiency with Schneider LC1K0610M7 and elevate your operations to new heights.

SKU: LC1K0610M7 Categories: , Brand:
Main
RangeTeSys
Product or component typeContactor
Device short nameLC1K
Device applicationControl
contactor applicationMotor control
Complementary
utilisation categoryAC-3
AC-3e
AC-4
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage220…230 V AC 50/60 Hz
Motor power kW1.5 kW at 220…230 V AC 50/60 Hz AC-3
2.2 kW at 380…415 V AC 50/60 Hz AC-3
3 kW at 440/690 V AC 50/60 Hz AC-3
1.5 kW at 220…230 V AC 50/60 Hz AC-3e
2.2 kW at 380…415 V AC 50/60 Hz AC-3e
3 kW at 440/690 V AC 50/60 Hz AC-3e
1.5 kW at 220…230 V AC 50/60 Hz AC-4
2.2 kW at 380…415 V AC 50/60 Hz AC-4
3 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NO
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C – 1 s for power circuit
85 A 50 °C – 5 s for power circuit
80 A 50 °C – 10 s for power circuit
60 A 50 °C – 30 s for power circuit
45 A 50 °C – 1 min for power circuit
40 A 50 °C – 3 min for power circuit
20 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in VA30 VA (at 20 °C)
Hold-in power consumption in VA4.5 VA (at 20 °C)
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8…1.15 Uc (at <50 °C) Drop-out: >= 0.20 Uc (at <50 °C)
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate3600 cyc/h
Auxiliary contacts typeType instantaneous 1 NO
Signalling circuit frequency<= 400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
mounting supportRail
Plate
Tightening torque0.8…1.3 N.m – on screw clamp terminals Philips No 2
0.8…1.3 N.m – on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m – on screw clamp terminals pozidriv No 2
Operating time10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance0.5 mm
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 6 A AC-3 at Ue <= 440 V
1.3 Mcycles 6 A AC-3e at Ue <= 440 V
0.05 Mcycles 36 A AC-4 at Ue <= 440 V
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
height58 mm
Width45 mm
Depth57 mm
Net weight0.18 kg
Environment
StandardsEN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
product certificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protectionIP2X conforming to VDE 0106
Protective treatmentTC conforming to IEC 60068
TC conforming to DIN 50016
Ambient air temperature for storage-50…80 °C
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5 cm
Package 1 Width6 cm
Package 1 Length6.5 cm
Package 1 Weight177 g
Unit Type of Package 2S02
Number of Units in Package 250
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight9.094 kg
Unit Type of Package 3P06
Number of Units in Package 3800
Package 3 Height75 cm
Package 3 Width80 cm
Package 3 Length60 cm
Package 3 Weight153.504 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : LC1K0610M7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1K0610M7 | TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NO aux. – 220…230 V AC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat