Schneider LC1K0901M7 Description

Schneider Electric is a global leader in energy management and automation solutions, renowned for its innovative and reliable products. One of their standout offerings is the Schneider LC1K0901M7, a compact and efficient contactor designed for various electrical applications. But why is this component so essential? Understanding the role of contactors in electrical systems is key—they are the workhorses that manage power distribution and ensure the smooth operation of various electrical devices.

Understanding the Schneider LC1K0901M7

What is the Schneider LC1K0901M7?

The Schneider LC1K0901M7 is a miniature contactor used to control electric motors, lighting systems, and other electrical loads. It’s part of Schneider Electric’s renowned TeSys K range, known for its compact design and high performance in industrial and commercial applications.

Key Features and Specifications

The LC1K0901M7 stands out with several key features:

  • Compact Design: Designed to save space in control panels, making it ideal for installations where space is at a premium.
  • High Electrical Durability: Engineered to withstand high levels of electrical stress, ensuring long-lasting performance.
  • Easy Installation: Features user-friendly mounting options and straightforward wiring, simplifying the installation process.
  • Versatile Applications: Suitable for a wide range of applications, from motor control to lighting circuits.

Detailed Features of Schneider LC1K0901M7

Compact Design

One of the main advantages of the LC1K0901M7 is its compact size. This allows for more efficient use of space within control panels, which is especially important in modern electrical installations where space is often limited.

High Electrical Durability

The LC1K0901M7 is built to handle high electrical currents and resist wear and tear over time. This durability translates into fewer replacements and maintenance needs, which is a significant cost-saving factor for businesses.

Easy Installation and Maintenance

Ease of installation is another highlight. The LC1K0901M7 is designed with simplicity in mind, making it accessible even to those who may not have extensive experience with electrical components. Maintenance is equally straightforward, further enhancing its appeal.

Versatile Applications

Whether you need a contactor for industrial machinery, HVAC systems, or lighting control, the LC1K0901M7 offers the versatility to meet a broad range of requirements. This adaptability makes it a popular choice across different sectors.

Technical Specifications

Electrical Ratings

The LC1K0901M7 operates at a voltage range of up to 690V AC and can handle currents up to 9A. This makes it suitable for controlling small motors and other electrical loads with moderate power requirements.

Mechanical Life

With a mechanical life of over 10 million operations, the LC1K0901M7 is designed for longevity. This high durability ensures that the contactor can perform reliably over many years of use.

Coil Voltage Range

The contactor is available in a range of coil voltages, with the M7 variant typically operating at 230V AC. This flexibility in coil voltage options makes it easier to integrate into various electrical systems.

Environmental Conditions

The LC1K0901M7 is designed to operate in a wide range of environmental conditions, from -25°C to +50°C, making it suitable for use in diverse climates and environments.

Applications of Schneider LC1K0901M7

Industrial Automation

In industrial settings, the LC1K0901M7 is often used to control machinery and processes. Its reliability and durability make it ideal for such demanding applications.

Motor Control

The contactor is commonly used in motor control circuits, providing the necessary switching functions to start and stop motors efficiently and safely.

HVAC Systems

In HVAC systems, the LC1K0901M7 is used to manage the operation of fans, compressors, and other components, ensuring efficient climate control.

Lighting Control

The contactor is also suitable for controlling lighting circuits, especially in commercial or industrial buildings where large lighting loads need to be managed.

Installation and Wiring Guidelines

Step-by-Step Installation Process

  1. Mounting: Secure the LC1K0901M7 in the control panel using the provided mounting options.
  2. Wiring: Connect the electrical wires to the appropriate terminals, following the wiring diagram provided by Schneider Electric.
  3. Testing: After installation, perform a test to ensure the contactor is functioning correctly.

Wiring Diagrams and Best Practices

Always refer to the official Schneider Electric wiring diagrams to ensure proper installation. Incorrect wiring can lead to malfunction or even damage to the contactor.

Safety Considerations

When working with electrical components, safety should always be a priority. Ensure that the power supply is turned off before starting the installation, and use proper protective equipment.

Advantages of Using Schneider LC1K0901M7

Reliability and Performance

The LC1K0901M7 is known for its reliability, providing consistent performance even in demanding applications. This reliability reduces downtime and maintenance costs.

Energy Efficiency

Designed to minimize energy loss, the LC1K0901M7 helps improve the overall energy efficiency of the systems it is integrated into. This can lead to significant cost savings over time.

Cost-Effectiveness

While the initial investment in a high-quality contactor like the LC1K0901M7 may be higher than some alternatives, its long lifespan and low maintenance requirements make it a cost-effective choice in the long run.

Comparison with Similar Contactors

Comparison with Other Schneider Contactors

Compared to other contactors in the TeSys K range, the LC1K0901M7 offers a balance of performance, size, and versatility, making it a well-rounded choice for various applications.

Comparison with Competitors’ Products

When compared to contactors from other manufacturers, the LC1K0901M7 stands out for its compact design and high durability. These features often make it a preferred choice among engineers and electricians.

Common Issues and Troubleshooting

Common Problems Faced

Some users may encounter issues such as contactor coil burnout or improper functioning due to incorrect installation.

Troubleshooting Tips

To address common issues, always double-check the wiring and ensure that the contactor is installed in accordance with Schneider Electric’s guidelines. If problems persist, consulting with a professional electrician or Schneider’s support team is advisable.

Maintenance and Longevity

Regular Maintenance Practices

To ensure the longevity of the LC1K0901M7, regular maintenance checks should be performed. This includes inspecting the wiring, cleaning the contacts, and checking for signs of wear.

Extending the Life of the Contactor

Keeping the contactor in a clean, dry environment and avoiding exposure to excessive heat or moisture can help extend its lifespan.

brands

Schneider Electric

Main
RangeTeSys
Product or component typeContactor
Device short nameLC1K
Device applicationControl
contactor applicationMotor control
Resistive load
Complementary
Utilisation categoryAC-3
AC-3e
AC-1
AC-4
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage220…230 V AC 50/60 Hz
Motor power kW2.2 kW at 220…230 V AC 50/60 Hz AC-3
4 kW at 380…415 V AC 50/60 Hz AC-3
4 kW at 440/690 V AC 50/60 Hz AC-3
2.2 kW at 220…230 V AC 50/60 Hz AC-3e
4 kW at 380…415 V AC 50/60 Hz AC-3e
4 kW at 440/690 V AC 50/60 Hz AC-3e
2.2 kW at 220…230 V AC 50/60 Hz AC-4
4 kW at 380…415 V AC 50/60 Hz AC-4
4 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NC
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C – 1 s for power circuit
85 A 50 °C – 5 s for power circuit
80 A 50 °C – 10 s for power circuit
60 A 50 °C – 30 s for power circuit
45 A 50 °C – 1 min for power circuit
40 A 50 °C – 3 min for power circuit
20 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm – Ith 20 A 50 Hz for power circuit
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in VA30 VA (at 20 °C)
Hold-in power consumption in VA4.5 VA (at 20 °C)
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8…1.15 Uc (at <50 °C) Drop-out: >= 0.20 Uc (at <50 °C)
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate3600 cyc/h
Auxiliary contacts typetype instantaneous 1 NC
Signalling circuit frequency<= 400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Operating time10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance0.5 mm
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 9 A AC-3 at Ue <= 440 V
1.3 Mcycles 9 A AC-3e at Ue <= 440 V
0.16 Mcycles 20 A AC-1 at Ue <= 690 V
0.02 Mcycles 54 A AC-4 at Ue <= 440 V
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Height58 mm
Width45 mm
Depth57 mm
Environment
StandardsEN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product certificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Protective treatmentTC conforming to IEC 60068
TC conforming to DIN 50016
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width6.200 cm
Package 1 Length6.500 cm
Package 1 Weight177.500 g
Unit Type of Package 2S02
Number of Units in Package 250
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.132 kg
Unit Type of Package 3P06
Number of Units in Package 3800
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight154.160 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : LC1K0901M7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1K0901M7 | TeSys K contactor – 3P – AC-3 <= 440 V 9 A – 1 NC aux. – 220…230 V AC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat