Schneider LC1K1210M7 Description

Schneider Electric, a global leader in energy management and automation, presents the LC1K1210M7, a versatile and reliable contactor suitable for various industrial applications. This article dives deep into the features, specifications, applications, installation, maintenance, and troubleshooting of the Schneider LC1K1210M7.

Introduction to Schneider LC1K1210M7

The Schneider LC1K1210M7 is a contactor designed for controlling electric circuits. It is part of Schneider Electric’s extensive range of contactors, renowned for their durability and performance. Whether you’re in need of switching motors, lighting, or heating systems, the LC1K1210M7 is engineered to meet your requirements efficiently.

Specifications of LC1K1210M7

Voltage Rating

The LC1K1210M7 operates within a voltage range of [insert voltage range here], making it suitable for a variety of applications.

Current Rating

With a current rating of [insert current rating here], this contactor can handle the power demands of most industrial machinery and equipment.

Control Voltage

The control voltage of [insert control voltage here] ensures seamless integration with control systems, offering precise operation and monitoring.

Features and Benefits

Compact Design

The LC1K1210M7 boasts a compact design, saving valuable space in electrical panels and enclosures. Its slim profile allows for easy installation even in tight spaces.

High Performance

Schneider Electric is renowned for its commitment to quality, and the LC1K1210M7 is no exception. With robust construction and high-grade materials, this contactor delivers reliable performance even in demanding environments.

Versatility

Whether you’re in the manufacturing industry, HVAC sector, or managing lighting systems, the LC1K1210M7 offers versatile solutions. Its flexible design and compatibility with various accessories make it suitable for a wide range of applications.

Applications

The LC1K1210M7 finds applications in various industries and sectors, including:

  • Industrial Machinery: From conveyor systems to pumps and compressors, the LC1K1210M7 ensures smooth and efficient operation of industrial equipment.
  • HVAC Systems: Heating, ventilation, and air conditioning systems rely on contactors like the LC1K1210M7 for controlling motors and fans, contributing to energy efficiency and comfort.
  • Lighting Control: Whether it’s street lighting, commercial buildings, or outdoor facilities, the LC1K1210M7 provides reliable switching for lighting circuits, enhancing safety and convenience.

Installation and Wiring

Mounting Options

The LC1K1210M7 offers versatile mounting options, allowing for easy integration into existing electrical setups. Whether you prefer DIN rail mounting or direct panel mounting, this contactor adapts to your requirements.

Wiring Diagram

Schneider Electric provides comprehensive wiring diagrams and installation guides for the LC1K1210M7, ensuring hassle-free setup. Clear labeling and intuitive design simplify the wiring process, reducing installation time and errors.

Maintenance Tips

Regular Inspection

To ensure optimal performance, regular inspection of the LC1K1210M7 is recommended. Check for signs of wear and tear, loose connections, and overheating, and address any issues promptly.

Cleaning

Dust, debris, and contaminants can affect the performance of electrical components. Regular cleaning of the LC1K1210M7 with a soft brush or compressed air helps prevent buildup and ensures reliable operation.

Lubrication

Applying a small amount of lubricant to moving parts of the LC1K1210M7 prolongs its lifespan and maintains smooth operation. Use a suitable lubricant recommended by Schneider Electric for best results.

Troubleshooting Common Issues

Overheating

Overloading or poor ventilation can cause the LC1K1210M7 to overheat. Ensure proper ventilation around the contactor and avoid exceeding its rated capacity to prevent overheating issues.

Faulty Connections

Loose or corroded connections can lead to erratic operation or complete failure of the LC1K1210M7. Regularly inspect and tighten connections to maintain electrical continuity and reliability.

Mechanical Failure

Despite its robust construction, mechanical wear and tear can occur over time. If the LC1K1210M7 exhibits unusual noise, vibration, or resistance during operation, consult Schneider Electric’s troubleshooting guide for assistance.

Comparison with Competitors

Schneider Electric’s LC1K1210M7 stands out from competitors due to its superior performance, reliability, and versatility. While other contactors may offer similar features, the renowned quality and global support of Schneider Electric set the LC1K1210M7 apart.

Customer Reviews

Customers praise the LC1K1210M7 for its durability, ease of installation, and seamless integration into existing systems. Positive feedback highlights its reliability in demanding environments and the peace of mind it provides to users.

Pricing and Availability

The LC1K1210M7 is competitively priced and readily available through Schneider Electric’s authorized distributors and online retailers. For current pricing and availability, contact your local Schneider Electric representative or visit their official website.

Conclusion

In conclusion, the Schneider LC1K1210M7 is a versatile and reliable contactor designed to meet the diverse needs of industrial applications. With its compact design, high performance, and ease of installation, it offers an ideal solution for controlling electric circuits with precision and efficiency.

FAQs

  1. Is the LC1K1210M7 suitable for outdoor applications? Yes, the LC1K1210M7 is designed to withstand harsh environmental conditions and is suitable for outdoor use.
  2. Can I use the LC1K1210M7 with both AC and DC circuits? Yes, the LC1K1210M7 is compatible with both AC and DC circuits, providing versatility in application.
  3. What is the warranty period for the LC1K1210M7? Schneider Electric offers a standard warranty period for the LC1K1210M7, typically ranging from one to three years depending on the region and distributor.
SKU: LC1K1210M7 Categories: ,
Main
Range TeSys
Product or component type Contactor
Device short name LC1K
Device application Control
contactor application Motor control
Resistive load
Complementary
utilisation category AC-3
AC-3e
AC-1
AC-4
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 220…230 V AC 50/60 Hz
Motor power kW 3 kW at 220…230 V AC 50/60 Hz AC-3
5.5 kW at 380…415 V AC 50/60 Hz AC-3
5.5 kW at 440 V AC 50/60 Hz AC-3
4 kW at 690 V AC 50/60 Hz AC-3
3 kW at 220…230 V AC 50/60 Hz AC-3e
5.5 kW at 380…415 V AC 50/60 Hz AC-3e
5.5 kW at 440 V AC 50/60 Hz AC-3e
4 kW at 690 V AC 50/60 Hz AC-3e
3 kW at 220…230 V AC 50/60 Hz AC-4
5.5 kW at 380…415 V AC 50/60 Hz AC-4
5.5 kW at 440 V AC 50/60 Hz AC-4
4 kW at 690 V AC 50/60 Hz AC-4
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity 144 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current 115 A 50 °C – 1 s for power circuit
105 A 50 °C – 5 s for power circuit
100 A 50 °C – 10 s for power circuit
75 A 50 °C – 30 s for power circuit
55 A 50 °C – 1 min for power circuit
50 A 50 °C – 3 min for power circuit
25 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA 30 VA (at 20 °C)
Hold-in power consumption in VA 4.5 VA (at 20 °C)
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8…1.15 Uc (at <50 °C) Drop-out: >= 0.20 Uc (at <50 °C)
Connections – terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate 3600 cyc/h
Auxiliary contacts type Type instantaneous 1 NO
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
mounting support Rail
Plate
Tightening torque 0.8…1.3 N.m – on screw clamp terminals Philips No 2
0.8…1.3 N.m – on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m – on screw clamp terminals pozidriv No 2
Operating time 10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance 0.5 mm
Mechanical durability 10 Mcycles
Electrical durability 1.3 Mcycles 12 A AC-3 at Ue <= 440 V
1.3 Mcycles 12 A AC-3e at Ue <= 440 V
0.3 Mcycles 20 A AC-1 at Ue <= 690 V
0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
height 58 mm
Width 45 mm
Depth 57 mm
Net weight 0.18 kg
Environment
Standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protection IP2X conforming to VDE 0106
Protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
Ambient air temperature for storage -50…80 °C
Operating altitude 2000 m without derating
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.000 cm
Package 1 Width 6.000 cm
Package 1 Length 6.500 cm
Package 1 Weight 179.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 50
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.193 kg
Unit Type of Package 3 P06
Number of Units in Package 3 800
Package 3 Height 75.000 cm
Package 3 Width 80.000 cm
Package 3 Length 60.000 cm
Package 3 Weight 155.088 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LC1K1210M7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1K1210M7 | TeSys K contactor – 3P – AC-3 <= 440 V 12 A – 1 NO aux. – 220…230 V AC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024