Product Overview: Schneider LC1K1610M7 Contactor

The Schneider Electric LC1K1610M7 is a compact and high-performance contactor from the TeSys K series, built to handle motor and load switching applications in confined electrical enclosures.

Key Features:

  • Brand: Schneider Electric

  • Series: TeSys K

  • Model Number: LC1K1610M7

  • Type: Electromechanical Contactor

  • Application: Motor control and load management

Electrical Specifications:

  • Rated Operational Current (Ie):
    – Up to 16A under AC-3 utilization category

  • Operational Voltage:
    – Supports up to 440V AC

  • Poles:
    3-Pole (3P) main contacts

  • Auxiliary Contact Configuration:
    1 NO (Normally Open) auxiliary contact

Coil Characteristics:

  • Control Voltage:
    220…230V AC

  • Coil Frequency:
    50/60 Hz

Design and Mounting:

  • Compact Size:
    – Optimized for tight spaces in control cabinets

  • Mounting Type:
    – DIN rail or screw mounting

  • Standards Compliance:
    – Conforms to IEC and international norms

Applications:

  • Motor control up to 7.5 kW

  • Lighting and HVAC systems

  • Automated control panels

  • Switching of resistive and inductive loads

  • Small and medium industrial machines

Benefits:

  • Reliable operation with extended lifespan

  • Easy installation and maintenance

  • Energy-efficient coil design

  • Compact form with high performance

  • Versatile use in industrial and commercial settings

Typical Industries:

  • Electrical Distribution and Automation

  • HVAC and Building Services

  • Food and Beverage Processing

  • Water and Utilities Management

  • Packaging and Manufacturing Industries

SKU: LC1K1610M7 Categories: , Brand:
Main
Range TeSys
Product or component type Contactor
Device short name LC1K
Device application Control
contactor application Motor control
Complementary
utilisation category AC-3
AC-3e
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current 16 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
16 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Control circuit type AC at 50/60 Hz
[Uc] control circuit voltage 220…230 V AC 50/60 Hz
Motor power kW 4 kW at 220…230 V AC 50/60 Hz AC-3
7.5 kW at 380…415 V AC 50/60 Hz AC-3
5.5 kW at 440 V AC 50/60 Hz AC-3
4 kW at 690 V AC 50/60 Hz AC-3
4 kW at 220…230 V AC 50/60 Hz AC-3e
7.5 kW at 380…415 V AC 50/60 Hz AC-3e
5.5 kW at 440 V AC 50/60 Hz AC-3e
4 kW at 690 V AC 50/60 Hz AC-3e
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity 160 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity 110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current 115 A 50 °C – 1 s for power circuit
105 A 50 °C – 5 s for power circuit
100 A 50 °C – 10 s for power circuit
75 A 50 °C – 30 s for power circuit
55 A 50 °C – 1 min for power circuit
50 A 50 °C – 3 min for power circuit
25 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance 3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA 30 VA (at 20 °C)
Hold-in power consumption in VA 4.5 VA (at 20 °C)
Heat dissipation 1.3 W
Control circuit voltage limits Operational: 0.8…1.15 Uc (at <50 °C) Drop-out: >= 0.20 Uc (at <50 °C)
Connections – terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate 3600 cyc/h
Auxiliary contacts type Type instantaneous 1 NO
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
mounting support Plate
Rail
Tightening torque 0.8…1.3 N.m – on screw clamp terminals Philips No 2
0.8…1.3 N.m – on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m – on screw clamp terminals pozidriv No 2
Operating time 10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance 0.5 mm
Mechanical durability 10 Mcycles
Electrical durability 1.3 Mcycles 16 A AC-3 at Ue <= 440 V
1.3 Mcycles 16 A AC-3e at Ue <= 440 V
Mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
height 58 mm
Width 45 mm
Depth 57 mm
Net weight 0.18 kg
Environment
Standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protection IP2X conforming to VDE 0106
Protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
Ambient air temperature for operation -25…50 °C
Ambient air temperature for storage -50…80 °C
Operating altitude 2000 m without derating
Flame retardance V1 conforming to UL 94
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.000 cm
Package 1 Width 6.000 cm
Package 1 Length 6.500 cm
Package 1 Weight 178.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 50
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.157 kg
Unit Type of Package 3 P06
Number of Units in Package 3 800
Package 3 Height 75.000 cm
Package 3 Width 80.000 cm
Package 3 Length 60.000 cm
Package 3 Weight 154.512 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LC1K1610M7

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LC1K1610M7 | TeSys K contactor – 3P – AC-3 <= 440 V 16 A – 1 NO aux. – 220…230 V AC coil”

There are no reviews yet.

SHOPPING CART

close
Let's Chat