-46%
, , ,

Schneider LP1K0610BD | TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NO aux. – 24 V DC coil

Schneider Electric
Availability:

Out of stock


Schneider LP1K0610BD | TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NO aux. – 24 V DC coil

1,694 EGP 3,136 EGP

Out of stock

Compare

Schneider LP1K0610BD | TeSys K contactor – 3P – AC-3 &lt;= 440 V 6 A – 1 NO aux. – 24 V DC coil

Schneider LP1K0610BD: The Ultimate Guide

In the realm of industrial automation, having the right components is crucial for ensuring seamless operations. The Schneider LP1K0610BD is one such component that stands out due to its reliability and efficiency. Whether you’re setting up a new system or upgrading an existing one, understanding this product’s intricacies can make all the difference.

What is Schneider LP1K0610BD?

The Schneider LP1K0610BD is a miniature contactor designed for switching electrical circuits. It is particularly useful in controlling electric motors and other high-power loads in industrial settings. This compact and efficient device is known for its robust performance and versatility, making it an essential component in various applications.

Key Features and Specifications

  • Voltage Rating: Up to 690V AC
  • Current Rating: 6A
  • Contact Configuration: 1 NO (Normally Open)
  • Coil Voltage: 24V DC
  • Operational Temperature Range: -25°C to 70°C

These specifications underline the LP1K0610BD’s ability to handle demanding tasks while maintaining high performance.

Design and Build Quality

When it comes to industrial components, durability is non-negotiable. The Schneider LP1K0610BD is constructed from high-quality materials that withstand harsh conditions. Its robust build ensures it can endure the rigors of industrial environments, providing long-lasting reliability.

Electrical Characteristics

Understanding the electrical characteristics of it is essential for optimal application. This contactor supports:

  • Voltage Ratings: Suitable for a wide range of voltages up to 690V AC, making it adaptable for different systems.
  • Current Ratings: With a current rating of 6A, it can handle various loads efficiently.
  • Contact Ratings: The 1 NO contact configuration ensures reliable switching for various electrical circuits.

Applications of Schneider LP1K0610BD

Industrial Automation

In automated systems, it acts as a key player in controlling machinery, ensuring that operations are executed precisely.

Motor Control

It’s extensively used in motor control applications, providing reliable performance in starting and stopping electric motors.

Other Relevant Applications

From lighting systems to heating equipment, the Schneider LP1K0610BD’s versatility makes it a valuable component in various industrial setups.

Installation Process

Installing it involves several steps to ensure safety and efficiency.

Pre-installation Requirements

  • Ensure Power is Off: Always start with turning off the power supply to avoid electrical hazards.
  • Check Compatibility: Verify that the contactor matches the system’s voltage and current requirements.

Step-by-Step Installation Guide

  1. Mount the Contactor: Securely mount the contactor in the designated location.
  2. Connect the Coils: Attach the coil connections according to the manufacturer’s instructions.
  3. Wire the Contacts: Connect the load wires to the contact points.
  4. Test the Installation: Once connected, test the contactor to ensure it operates correctly.

Safety Precautions

  • Use Proper Tools: Ensure you use insulated tools to prevent electrical shocks.
  • Follow Manufacturer Guidelines: Adhering to the manufacturer’s installation guidelines is crucial for safety and performance.

Performance and Efficiency

The Schneider LP1K0610BD is known for its operational efficiency and consistent performance. It operates effectively under various conditions, making it a reliable choice for demanding industrial applications. Its longevity and reliability are backed by numerous user testimonials and case studies.

Main
RangeTeSys
Product or component typeContactor
Device short nameLP1K
contactor applicationMotor control
Complementary
Utilisation categoryAC-3
AC-3e
AC-4
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Control circuit typeDC standard
[Uc] control circuit voltage24 V DC
Motor power kW1.5 kW at 220…230 V AC 50/60 Hz AC-3
2.2 kW at 380…415 V AC 50/60 Hz AC-3
3 kW at 440/690 V AC 50/60 Hz AC-3
1.5 kW at 220…230 V AC 50/60 Hz AC-3e
2.2 kW at 380…415 V AC 50/60 Hz AC-3e
3 kW at 440/690 V AC 50/60 Hz AC-3e
1.5 kW at 220…230 V AC 50/60 Hz AC-4
2.2 kW at 380…415 V AC 50/60 Hz AC-4
3 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NO
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C – 1 s for power circuit
85 A 50 °C – 5 s for power circuit
80 A 50 °C – 10 s for power circuit
60 A 50 °C – 30 s for power circuit
45 A 50 °C – 1 min for power circuit
40 A 50 °C – 3 min for power circuit
20 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in W3 W (at 20 °C)
Hold-in power consumption in W3 W at 20 °C
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8…1.15 Uc (at <50 °C) Drop-out: >= 0.10 Uc (at <50 °C)
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end
Maximum operating rate3600 cyc/h
Auxiliary contacts typetype instantaneous 1 NO
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Mounting supportRail
Plate
Tightening torque0.8…1.3 N.m – on screw clamp terminals Philips No 2
0.8…1.3 N.m – on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m – on screw clamp terminals pozidriv No 2
Operating time30…40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 6 A AC-3 at Ue <= 440 V
1.3 Mcycles 6 A AC-3e at Ue <= 440 V
0.05 Mcycles 36 A AC-4 at Ue <= 440 V
Height58 mm
Width45 mm
Depth57 mm
Net weight0.225 kg
Environment
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
Product certificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protectionIP2X
Ambient air temperature for operation-25…50 °C
Ambient air temperature for storage-50…80 °C
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width6.000 cm
Package 1 Length6.500 cm
Package 1 Weight223.000 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.151 kg
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight154.416 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LP1K0610BD | TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NO aux. – 24 V DC coil”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat