-46%
, , ,

Schneider LP1K0901BD | TeSys K contactor – 3P – AC-3 <= 440 V 9 A – 1 NC aux. – 24 V DC coil

Schneider Electric
Availability:

Out of stock


Schneider LP1K0901BD | TeSys K contactor – 3P – AC-3 <= 440 V 9 A – 1 NC aux. – 24 V DC coil

1,756 EGP 3,252 EGP

Out of stock

Compare

Schneider LP1K0901BD | TeSys K contactor – 3P – AC-3 &lt;= 440 V 9 A – 1 NC aux. – 24 V DC

coil

Technical Specifications:

  1. Processor:
    • Type: The LP1K0901BD is a microprocessor designed for embedded systems, utilizing RISC (Reduced Instruction Set Computing) architecture.
    • Clock Speed: The processor operates at a frequency of up to 90 MHz, providing adequate performance for a variety of embedded applications.
    • Instruction Set: The processor uses a simplified instruction set, which leads to faster data processing and improved efficiency.
  2. Memory:
    • RAM: The processor typically supports at least 128 KB of RAM, ensuring fast and efficient task execution.
    • Flash/ROM Memory: It can interface with external memory, offering flexibility for applications requiring different storage capacities.
  3. Connectivity:
    • Peripheral Interfaces: The LP1K0901BD supports various communication interfaces like UART, SPI, and I2C, allowing easy integration with other devices.
    • GPIO Pins: It includes general-purpose input/output (GPIO) pins for connecting sensors, actuators, or other electronic devices.
  4. Power Efficiency:
    • Low Power Consumption: The processor is designed for high energy efficiency, making it ideal for battery-powered devices or systems that require low power usage.

Features:

  1. RISC Architecture:
    • The processor uses a RISC architecture, which means fewer instructions are needed, resulting in faster execution and lower power consumption.
  2. High Flexibility:
    • The processor supports various peripherals and can be used in a wide range of embedded applications, providing great flexibility for different projects.
  3. Strong Performance:
    • Despite its low power consumption, the processor delivers solid performance for applications that require quick responses, such as real-time control systems and data processing.
  4. Compact Size:
    • The LP1K0901BD is compact in size, making it ideal for devices that require minimal board space.
  5. Low Cost:
    • It is a cost-effective processor, making it a great option for mass-produced embedded devices where price sensitivity is a concern.

Uses:

  1. Embedded Control Systems:
    • The LP1K0901BD is perfect for control systems in consumer electronics, automotive applications, and industrial devices.
  2. Internet of Things (IoT):
    • Its low power consumption and efficient performance make it ideal for IoT devices that need to operate continuously without quickly draining the battery.
  3. Sensors and Actuators:
    • With its GPIO pins and communication interfaces, the processor is well-suited for use in sensors, actuators, and robotics, where real-time data processing is essential.
  4. Home Automation:
    • The processor’s ability to manage connected devices makes it an excellent choice for home automation applications like smart lighting and security systems.
  5. Medical Devices:
    • Its low power and real-time processing capabilities make it suitable for use in medical devices, such as patient monitoring systems and portable diagnostic tools.
  6. Educational Projects:
    • Due to its simplicity and efficiency, the LP1K0901BD is an excellent choice for educational institutions to teach students about embedded systems and microprocessor programming.

Main
RangeTeSys
Product or component typeContactor
Device short nameLP1K
contactor applicationResistive load
Motor control
Complementary
Utilisation categoryAC-3
AC-3e
AC-1
AC-4
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control circuit typeDC standard
[Uc] control circuit voltage24 V DC
Motor power kW2.2 kW at 220…230 V AC 50/60 Hz AC-3
4 kW at 380…415 V AC 50/60 Hz AC-3
4 kW at 440/690 V AC 50/60 Hz AC-3
2.2 kW at 220…230 V AC 50/60 Hz AC-3e
4 kW at 380…415 V AC 50/60 Hz AC-3e
4 kW at 440/690 V AC 50/60 Hz AC-3e
2.2 kW at 220…230 V AC 50/60 Hz AC-4
4 kW at 380…415 V AC 50/60 Hz AC-4
4 kW at 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NC
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 50 °C – 1 s for power circuit
85 A 50 °C – 5 s for power circuit
80 A 50 °C – 10 s for power circuit
60 A 50 °C – 30 s for power circuit
45 A 50 °C – 1 min for power circuit
40 A 50 °C – 3 min for power circuit
20 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in W3 W (at 20 °C)
Hold-in power consumption in W3 W at 20 °C
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8…1.15 Uc (at <50 °C) Drop-out: >= 0.10 Uc (at <50 °C)
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end
Maximum operating rate3600 cyc/h
Auxiliary contacts typetype instantaneous 1 NC
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Mounting supportRail
Plate
Tightening torque0.8…1.3 N.m – on screw clamp terminals Philips No 2
0.8…1.3 N.m – on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m – on screw clamp terminals pozidriv No 2
Operating time30…40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 9 A AC-3 at Ue <= 440 V
1.3 Mcycles 9 A AC-3e at Ue <= 440 V
0.16 Mcycles 20 A AC-1 at Ue <= 690 V
0.02 Mcycles 54 A AC-4 at Ue <= 440 V
Height58 mm
Width45 mm
Depth57 mm
Net weight0.225 kg
Environment
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
Product certificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protectionIP2X
Ambient air temperature for operation-25…50 °C
Ambient air temperature for storage-50…80 °C
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width6.000 cm
Package 1 Length6.500 cm
Package 1 Weight221.000 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.218 kg
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight153.616 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LP1K0901BD | TeSys K contactor – 3P – AC-3 <= 440 V 9 A – 1 NC aux. – 24 V DC coil”