-46%
, , ,

Schneider LP1K1201BD | TeSys K contactor – 3P – AC-3 <= 440 V 12 A – 1 NC aux. – 24 V DC coil

Schneider Electric
Availability:

In stock


Schneider LP1K1201BD | TeSys K contactor – 3P – AC-3 <= 440 V 12 A – 1 NC aux. – 24 V DC coil

1,825 EGP 3,380 EGP

In stock

Compare

Schneider LP1K1201BD | TeSys K contactor – 3P – AC-3 &lt;= 440 V 12 A – 1 NC aux. – 24 V DC

coil

Schneider LP1K1201BD: Comprehensive Overview

Introduction

The Schneider LP1K1201BD is an essential component in industrial automation and control systems. This guide provides a detailed look at the LP1K1201BD, including its features, applications, and benefits.

Overview of Schneider Electric

Company Background

Schneider Electric is a leading global provider of energy management and automation solutions. With a reputation for innovation and quality, Schneider Electric plays a crucial role in various industrial and residential sectors.

Commitment to Quality and Innovation

Schneider Electric’s commitment to excellence is reflected in its product offerings. The LP1K1201BD exemplifies the company’s dedication to delivering high-performance and reliable solutions.

Detailed Description of Schneider LP1K1201BD

Product Specifications

it is a contactor designed for use in motor control and switching applications. Key specifications include:

  • Type: Contactor
  • Current Rating: 12A
  • Voltage Rating: Up to 690V AC
  • Number of Contacts: 3 Normally Open (NO)
  • Coil Voltage: 24V DC
  • Mounting Type: DIN Rail Mounting
  • Protection Class: IP20

Key Features

  • High Switching Capacity: Designed to handle high-current loads efficiently.
  • Compact Design: Space-saving design for easy integration into control panels.
  • Reliable Performance: Ensures consistent and reliable operation in various conditions.
  • Visual Indicators: Equipped with indicators for easy monitoring and status checks.

Applications of Schneider LP1K1201BD

Residential Use

In residential applications, it can be used in home automation systems, controlling various electrical devices and enhancing energy efficiency.

Commercial Use

For commercial environments, including offices and retail spaces, this contactor is ideal for managing lighting systems, HVAC units, and other electrical equipment, improving operational reliability and energy management.

Industrial Use

In industrial settings, it is critical for controlling motors, pumps, and other machinery, ensuring efficient and safe operation in demanding environments.

Installation and Setup

Pre-Installation Considerations

Before installing it, ensure its current and voltage ratings are compatible with your system. Verify that the installation site allows for proper mounting and ventilation.

Step-by-Step Installation Guide

  1. Prepare the Installation Site: Ensure the area is clean and accessible.
  2. Mounting: Attach the contactor to the DIN rail using the provided mounting hardware.
  3. Wiring: Connect the contactor to the electrical system according to the wiring diagram in the manual.
  4. Configuration: Set up the coil voltage and check connections.
  5. Testing: Perform a test to ensure proper operation and verify that all indicators are functioning correctly.

Safety Features and Compliance

Built-in Safety Mechanisms

it includes several safety features:

  • Overload Protection: Protects against overcurrent conditions to prevent damage.
  • Short Circuit Protection: Shields the contactor and connected equipment from short circuits.
  • Temperature Compensation: Maintains accurate performance by adjusting for temperature changes.

Compliance with International Standards

The LP1K1201BD meets international standards such as IEC and UL, ensuring high safety and performance standards.

Advantages of Using Schneider LP1K1201BD

Reliability and Durability

The LP1K1201BD is designed for long-term reliability and durability, even in harsh environments, thanks to its robust construction and high-quality materials.

Cost-Effectiveness

The contactor offers a cost-effective solution for motor control and switching applications, providing savings in both installation and maintenance.

Ease of Use

With its user-friendly design and clear indicators, the LP1K1201BD is easy to install and operate, enhancing overall system efficiency.

Main
RangeTeSys
Product or component typeContactor
Device short nameLP1K
contactor applicationResistive load
Motor control
Complementary
Utilisation categoryAC-3
AC-3e
AC-1
AC-4
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control circuit typeDC standard
[Uc] control circuit voltage24 V DC
Motor power kW3 kW at 220…230 V AC 50/60 Hz AC-3
5.5 kW at 380…415 V AC 50/60 Hz AC-3
5.5 kW at 440 V AC 50/60 Hz AC-3
4 kW at 690 V AC 50/60 Hz AC-3
3 kW at 220…230 V AC 50/60 Hz AC-3e
5.5 kW at 380…415 V AC 50/60 Hz AC-3e
5.5 kW at 440 V AC 50/60 Hz AC-3e
4 kW at 690 V AC 50/60 Hz AC-3e
3 kW at 220…230 V AC 50/60 Hz AC-4
5.5 kW at 380…415 V AC 50/60 Hz AC-4
5.5 kW at 440 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NC
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity144 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current115 A 50 °C – 1 s for power circuit
105 A 50 °C – 5 s for power circuit
100 A 50 °C – 10 s for power circuit
75 A 50 °C – 30 s for power circuit
55 A 50 °C – 1 min for power circuit
50 A 50 °C – 3 min for power circuit
25 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in W3 W (at 20 °C)
Hold-in power consumption in W3 W at 20 °C
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8…1.15 Uc (at <50 °C) Drop-out: >= 0.10 Uc (at <50 °C)
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end
Maximum operating rate3600 cyc/h
Auxiliary contacts typetype instantaneous 1 NC
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Mounting supportRail
Plate
Tightening torque0.8…1.3 N.m – on screw clamp terminals Philips No 2
0.8…1.3 N.m – on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m – on screw clamp terminals pozidriv No 2
Operating time30…40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
Safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 12 A AC-3 at Ue <= 440 V
1.3 Mcycles 12 A AC-3e at Ue <= 440 V
0.3 Mcycles 20 A AC-1 at Ue <= 690 V
0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Height58 mm
Width45 mm
Depth57 mm
Net weight0.225 kg
Environment
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
Product certificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protectionIP2X
Ambient air temperature for operation-25…50 °C
Ambient air temperature for storage-50…80 °C
Permissible ambient air temperature around the device-40…70 °C at Uc
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.000 cm
Package 1 Width6.000 cm
Package 1 Length6.500 cm
Package 1 Weight221.000 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight9.101 kg
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight153.616 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LP1K1201BD | TeSys K contactor – 3P – AC-3 <= 440 V 12 A – 1 NC aux. – 24 V DC coil”