The Schneider LR2K0307 is a part of the TeSys K series, designed to provide efficient protection for motors and electrical circuits against thermal overload. This differential thermal overload relay is engineered to ensure the safe operation of motor control circuits by protecting them from overheating caused by prolonged overcurrent conditions. With a current range of 1.2 to 1.8 A and class 10A time delay, the LR2K0307 is ideal for industrial and commercial applications requiring reliable motor protection.

Technical Specifications

Here are the key technical details of the LR2K0307 thermal overload relay:

  • Model: LR2K0307
  • Brand: Schneider Electric
  • Type: Differential Thermal Overload Relay
  • Current Range: 1.2 to 1.8 A
  • Protection Class: Class 10A
  • Mounting: Designed for easy installation with TeSys contactors
  • Voltage Rating: Compatible with 3-phase AC systems
  • Design: Compact and robust for panel mounting
  • Adjustable Settings: Adjustable current settings to match the protection needs of the motor
  • Trip Mechanism: Thermal trip based on the motor’s heat generation under overload conditions

Key Features

The Schneider LR2K0307 thermal overload relay offers several features that make it an excellent choice for motor protection:

  1. Precise Motor Protection – Provides reliable protection against thermal overload by monitoring motor temperature and preventing overheating.
  2. Adjustable Range – The adjustable current range of 1.2 to 1.8 A allows for customization according to motor specifications, ensuring accurate protection.
  3. Class 10A Time Delay – Offers a Class 10A time delay, which provides enough time for transient currents without triggering unnecessary shutdowns.
  4. Easy Integration – Specifically designed for seamless integration with TeSys K contactors, making installation quick and simple.
  5. Durable and Reliable – Built with high-quality materials to ensure long-lasting protection even under harsh operating conditions.
  6. Enhanced Safety – Ensures safe operation by preventing overheating, thereby reducing the risk of fire, equipment damage, and motor failure.

Applications

The LR2K0307 thermal overload relay is primarily used for protecting motors and electrical equipment in various industrial and commercial applications:

  1. Motor Protection – Protects motors from thermal overloads caused by sustained overcurrent conditions, preventing damage and downtime.
  2. Industrial Machinery – Commonly used in industrial applications where machinery and equipment are powered by electric motors, ensuring their safe operation.
  3. HVAC Systems – Ideal for protecting motors in heating, ventilation, and air conditioning systems, ensuring system reliability.
  4. Conveyor Systems – Provides motor protection in conveyor systems to prevent overheating and reduce maintenance costs.
  5. Pumps and Compressors – Used to protect pumps and compressors in various industries from overloads and potential failure due to excess heat.

 

brands

Schneider Electric

Main
RangeTeSys
product nameTeSys LRK
Product or component typeDifferential thermal overload relay
Device short nameLR2K
Relay applicationMotor protection
Product compatibilityLC1K
LP1K
LP4K
LC7K
network typeAC
DC
Thermal overload classClass 10A conforming to IEC 60947-4-1
Thermal protection adjustment range1.2…1.8 A
[Ui] rated insulation voltagePower circuit: 690 V conforming to BS 4941
Power circuit: 690 V conforming to IEC 60947
Power circuit: 750 V conforming to VDE 0110 group C
Power circuit: 600 V conforming to CSA C22.2 No 14
Complementary
Network frequency<= 400 Hz
Mounting supportUnder contactor
Plate, with specific accessories
Rail, with specific accessories
Auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal current6 A for signalling circuit
[Ue] rated operational voltage<= 690 V for power circuit
690 V AC AC-15 for signalling circuit
250 V DC DC-13 for signalling circuit
Associated fuse rating6 A gG for signalling circuit conforming to VDE 0660
6 A gG for signalling circuit conforming to IEC 60947
[Uimp] rated impulse withstand voltage6 kV
Power dissipation per pole2 W
Phase failure sensitivityYes conforming to IEC 60947-4-1
Local signallingTrip indicator (yellow)
Control typeRed push-button: trip test function
Blue push-button: stop and manual reset
selector switch: manual or automatic reset
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque1.3 N.m – on screw clamp terminals – with screwdriver Philips No 2
1.3 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
1.3 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Height58 mm
Width45 mm
Depth65 mm
Product weight0.145 kg
Environment
StandardsIEC 60947
NF C 63-650
VDE 0660
BS 4941
Product certificationsUL
CSA
UKCA
Protective treatmentTC conforming to IEC 60068
TC conforming to DIN 50016
IP degree of protectionIP2X conforming to IEC 60529
Ambient air temperature for operation-20…55 °C without derating conforming to IEC 60947
-30…60 °C with derating conforming to IEC 60947
Ambient air temperature for storage-40…70 °C
Operating altitude2000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Mechanical robustnessShocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations NO contact: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations NC contact: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.300 cm
Package 1 Width7.000 cm
Package 1 Length5.000 cm
Package 1 Weight157.000 g
Unit Type of Package 2S02
Number of Units in Package 241
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.760 kg
Unit Type of Package 3P06
Number of Units in Package 3656
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight119.428 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LR2K0307 | TeSys K – differential thermal overload relays – 1.2…1.8 A – class 10A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat