-46%

Schneider LR2K0308 | TeSys K – differential thermal overload relays – 1.8…2.6 – class 10A

Schneider Electric
Availability:

In stock


Schneider LR2K0308 | TeSys K – differential thermal overload relays – 1.8…2.6 – class 10A

1,875 EGP 3,473 EGP

In stock

Compare

Schneider LR2K0308: In-Depth Guide

Introduction

it is a key component in motor protection and control systems. This detailed guide will explore the features, applications, and benefits of the LR2K0308, helping you understand its role and advantages in various settings.

Overview of Schneider Electric

Company Background

Schneider Electric is a renowned global leader in energy management and automation. With a history of innovation and a commitment to quality, Schneider Electric delivers advanced solutions across various sectors.

Commitment to Quality and Innovation

Schneider Electric’s dedication to quality and innovation is evident in products like the LR2K0308. The company’s continuous research and development efforts ensure that their offerings are at the cutting edge of technology.

Detailed Description of Schneider LR2K0308

Product Specifications

it is a thermal overload relay designed for motor protection. Key specifications include:

  • Type: Thermal Overload Relay
  • Current Range: 0.4-0.63A
  • Voltage Rating: Up to 690V AC
  • Frequency: 50/60 Hz
  • Mounting Type: DIN Rail Mounting
  • Protection Class: IP20

Key Features

  • Thermal Protection: Reliable protection against motor overloads and overheating.
  • Adjustable Settings: Customizable overload settings for different motor requirements.
  • Compact Design: Space-saving design for easy integration into control panels.
  • Visual Indicators: Clear indicators for status monitoring and fault detection.

Applications of Schneider LR2K0308

Residential Use

In residential applications, it can be used to protect motors in household appliances such as HVAC systems, ensuring their safe and efficient operation.

Commercial Use

For commercial settings, including offices and retail spaces, it safeguards motors in equipment like air conditioning units and elevators, reducing maintenance needs and improving reliability.

Industrial Use

In industrial environments, it is crucial for protecting motors in machinery and equipment, helping to prevent downtime and extend the life of the equipment.

Installation and Setup

Pre-Installation Considerations

Before installing the Schneider LR2K0308, ensure that the relay’s current and voltage ratings match your system’s specifications. Check that the installation site allows for proper mounting and ventilation.

Step-by-Step Installation Guide

  1. Prepare the Installation Site: Ensure the area is clean and accessible.
  2. Mounting: Attach the relay to the DIN rail using the provided mounting hardware.
  3. Wiring: Connect the relay to the motor and control circuit as per the wiring diagram in the manual.
  4. Configuration: Adjust the overload settings using the relay’s controls to match the motor’s specifications.
  5. Testing: Inspect all connections and perform a test to confirm proper operation.
SKU: LR2K0308 Category:
Main
RangeTeSys
Product nameTeSys LRK
Product or component typeDifferential thermal overload relay
Device short nameLR2K
relay applicationMotor protection
Product compatibilityLP4K
LC1K
LC7K
LP1K
Network typeDC
AC
Thermal overload classClass 10A conforming to IEC 60947-4-1
Thermal protection adjustment range1.8…2.6 A
[Ui] rated insulation voltagePower circuit: 690 V conforming to BS 4941
Power circuit: 690 V conforming to IEC 60947
Power circuit: 750 V conforming to VDE 0110 group C
Power circuit: 600 V conforming to CSA C22.2 No 14
Complementary
Network frequency<= 400 Hz
Mounting supportUnder contactor
Plate, with specific accessories
Rail, with specific accessories
Auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal current6 A for signalling circuit
[Ue] rated operational voltage<= 690 V for power circuit
690 V AC AC-15 for signalling circuit
250 V DC DC-13 for signalling circuit
Associated fuse rating6 A gG for signalling circuit conforming to VDE 0660
6 A gG for signalling circuit conforming to IEC 60947
[Uimp] rated impulse withstand voltage6 kV
Power dissipation per pole2 W
Phase failure sensitivityYes conforming to IEC 60947-4-1
Local signallingTrip indicator (yellow)
Control typeRed push-button: trip test function
Blue push-button: stop and manual reset
selector switch: manual or automatic reset
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque1.3 N.m – on screw clamp terminals – with screwdriver Philips No 2
1.3 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
1.3 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Height58 mm
Width45 mm
Depth65 mm
Net weight0.145 kg
Environment
StandardsBS 4941
VDE 0660
IEC 60947
NF C 63-650
Product certificationsUL
CSA
UKCA
Protective treatmentTC conforming to IEC 60068
TC conforming to DIN 50016
IP degree of protectionIP2X conforming to IEC 60529
Ambient air temperature for operation-20…55 °C without derating conforming to IEC 60947
-30…60 °C with derating conforming to IEC 60947
Ambient air temperature for storage-40…70 °C
Operating altitude2000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Mechanical robustnessShocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations NO contact: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations NC contact: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.200 cm
Package 1 Width4.800 cm
Package 1 Length8.500 cm
Package 1 Weight157.000 g
Unit Type of Package 2S02
Number of Units in Package 241
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.800 kg
Unit Type of Package 3P06
Number of Units in Package 3656
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight118.772 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LR2K0308 | TeSys K – differential thermal overload relays – 1.8…2.6 – class 10A”