Schneider LR2K0308 | TeSys K – differential thermal overload relays – 1.8…2.6 – class 10A

Schneider Electric
Availability:

Out of stock


Schneider LR2K0308 | TeSys K – differential thermal overload relays – 1.8…2.6 – class 10A

1,875.30 EGP 3,472.78 EGP

Out of stock

Compare

Schneider LR2K0308 | TeSys K – differential thermal overload relays – 1.8…2.6 – class 10A

Technical Specifications

  • Brand: Schneider Electric

  • Series: TeSys K

  • Model: LR2K0308

  • Type: Differential Thermal Overload Relay

  • Adjustable Current Range: 1.8 to 2.6 A

  • Tripping Class: 10A (Fast Motor Protection)

  • Phase Imbalance Detection: Yes

  • Reset Mode: Manual and Automatic Reset

  • Mounting Type: Direct mounting on TeSys K contactors

  • Connection Type: Screw clamp terminals

  • Operating Temperature: -20°C to +60°C

  • Compliance Standards: IEC 60947-4-1, IEC 60947-5-1

Key Features

  • Reliable Motor Protection: Protects against overloads, phase loss, and unbalanced currents.

  • Adjustable Current Settings: Fine-tunes between 1.8 A and 2.6 A for precise protection.

  • Quick Tripping (Class 10A): Ensures rapid response to overload conditions, preventing motor damage.

  • Auto/Manual Reset Options: Provides flexibility in reset operations, improving system reliability.

  • Compact and Space-Saving Design: Directly mounts onto TeSys K contactors for easy installation.

  • Phase Failure Protection: Trips the circuit in case of phase loss, preventing motor overheating.

  • Durable Construction: Designed for industrial environments with high switching durability.

Applications

  • Industrial Motor Protection: Ideal for small three-phase motors in machinery and automation systems.

  • Pumps and Compressors: Ensures safe operation by preventing overheating and overload.

  • HVAC Systems: Protects fans, blowers, and air handling units from excessive loads.

  • Material Handling & Conveyors: Prevents motor failure in automated production lines.

  • Machine Tools: Used in drills, CNC machines, and lathes to prevent damage from excessive loads.

Main
RangeTeSys
Product nameTeSys LRK
Product or component typeDifferential thermal overload relay
Device short nameLR2K
relay applicationMotor protection
Product compatibilityLP4K
LC1K
LC7K
LP1K
Network typeDC
AC
Thermal overload classClass 10A conforming to IEC 60947-4-1
Thermal protection adjustment range1.8…2.6 A
[Ui] rated insulation voltagePower circuit: 690 V conforming to BS 4941
Power circuit: 690 V conforming to IEC 60947
Power circuit: 750 V conforming to VDE 0110 group C
Power circuit: 600 V conforming to CSA C22.2 No 14
Complementary
Network frequency<= 400 Hz
Mounting supportUnder contactor
Plate, with specific accessories
Rail, with specific accessories
Auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal current6 A for signalling circuit
[Ue] rated operational voltage<= 690 V for power circuit
690 V AC AC-15 for signalling circuit
250 V DC DC-13 for signalling circuit
Associated fuse rating6 A gG for signalling circuit conforming to VDE 0660
6 A gG for signalling circuit conforming to IEC 60947
[Uimp] rated impulse withstand voltage6 kV
Power dissipation per pole2 W
Phase failure sensitivityYes conforming to IEC 60947-4-1
Local signallingTrip indicator (yellow)
Control typeRed push-button: trip test function
Blue push-button: stop and manual reset
selector switch: manual or automatic reset
Connections – terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Tightening torque1.3 N.m – on screw clamp terminals – with screwdriver Philips No 2
1.3 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
1.3 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Height58 mm
Width45 mm
Depth65 mm
Net weight0.145 kg
Environment
StandardsBS 4941
VDE 0660
IEC 60947
NF C 63-650
Product certificationsUL
CSA
UKCA
Protective treatmentTC conforming to IEC 60068
TC conforming to DIN 50016
IP degree of protectionIP2X conforming to IEC 60529
Ambient air temperature for operation-20…55 °C without derating conforming to IEC 60947
-30…60 °C with derating conforming to IEC 60947
Ambient air temperature for storage-40…70 °C
Operating altitude2000 m without derating
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Mechanical robustnessShocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations NO contact: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations NC contact: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.200 cm
Package 1 Width4.800 cm
Package 1 Length8.500 cm
Package 1 Weight157.000 g
Unit Type of Package 2S02
Number of Units in Package 241
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.800 kg
Unit Type of Package 3P06
Number of Units in Package 3656
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight118.772 kg
Contractual warranty
Warranty18 months