Schneider Electric is a renowned name in the world of electrical engineering, known for its innovative solutions and reliable products. Among its extensive range of offerings, the Schneider LR2K0316 overload relay stands out as a critical component in safeguarding electrical systems. But what makes this particular model so special? Let’s dive in and find out.

Overview of Schneider LR2K0316

The Schneider LR2K0316 is an overload relay designed to protect electric motors from overloads, phase failures, and other electrical anomalies. It’s a part of Schneider’s TeSys line, which is known for its robustness and reliability. This relay ensures that motors operate within their safe limits, preventing potential damage and extending their lifespan.

Technical Specifications

Understanding the technical specifications of the LR2K0316 is crucial for proper application:

  • Voltage Ratings: The LR2K0316 operates efficiently at various voltage levels, making it versatile for different electrical setups.
  • Current Ratings: It supports a current range suitable for many industrial applications, ensuring flexibility and adaptability.
  • Temperature Ranges: Designed to work under a wide range of temperatures, this relay remains reliable in various environmental conditions.

Design and Build

The LR2K0316 is built to last, featuring:

  • Physical Dimensions: Compact and easy to integrate into existing systems.
  • Materials Used: High-quality, durable materials ensure long-term reliability.
  • Durability and Reliability: Engineered to withstand harsh industrial environments, reducing the need for frequent replacements.

Functionality

So, how does the Schneider LR2K0316 work? Essentially, it monitors the current flowing through an electric motor. If it detects an overload, it trips the circuit to prevent damage. This mechanism is vital in protecting motors from overheating and potential failures, ensuring smooth and efficient operation.

Installation Process

Installing the LR2K0316 is straightforward, but safety is paramount:

  1. Step-by-Step Installation Guide:
    • Turn off the power supply.
    • Mount the relay in the designated spot.
    • Connect the wiring as per the diagram provided in the manual.
    • Test the setup to ensure proper functioning.
  2. Safety Precautions:
    • Always follow the manufacturer’s instructions.
    • Use appropriate personal protective equipment (PPE).
    • Ensure the power is completely off before starting the installation.

Usage Scenarios

The Schneider LR2K0316 is versatile, finding applications in various sectors:

  • Industrial Applications: Used in factories and production lines to protect motors driving heavy machinery.
  • Commercial Applications: Ensures the safety of motors in commercial HVAC systems, elevators, and more.

Advantages of Using LR2K0316

Why choose the LR2K0316? Here are some compelling reasons:

  • Enhanced Safety: Prevents electrical fires and equipment damage by accurately detecting overloads.
  • Efficiency Improvements: Helps motors run more efficiently, reducing downtime.
  • Cost Savings: By preventing motor damage, it saves on costly repairs and replacements.

Comparison with Other Models

When selecting an overload relay, it’s crucial to compare:

  • Similar Schneider Models: The LR2K0316 vs. LR2K0301 – the former offers better current ratings and improved durability.
  • Competitors: Compared to relays from other brands, the LR2K0316 stands out due to its superior build quality and reliable performance.

Maintenance and Troubleshooting

To keep the LR2K0316 in top condition:

  • Regular Maintenance Tips: Periodically check connections, clean the unit, and test the relay’s functionality.
  • Common Issues and Solutions: If the relay trips frequently, it might indicate an underlying issue with the motor or wiring. Inspect and resolve these issues promptly.

User Reviews and Testimonials

Feedback from users highlights the LR2K0316’s reliability and performance:

  • Industry Professionals: Many professionals praise its ease of installation and consistent protection.
  • Customer Satisfaction Ratings: High satisfaction scores indicate widespread approval and trust in the product.

Environmental Impact

In today’s eco-conscious world, the LR2K0316 is a responsible choice:

  • Energy Efficiency: Designed to minimize energy wastage.
  • Compliance with Environmental Standards: Meets various international standards, making it a green choice.

Price and Availability

Considering purchasing the LR2K0316? Here’s what you need to know:

  • Market Price Range: Generally priced competitively within the range of $50 to $100, depending on the supplier.
  • Where to Buy: Available through authorized Schneider Electric distributors, online retailers, and electrical supply stores.

Conclusion

The Schneider LR2K0316 overload relay is an exemplary product that combines reliability, efficiency, and safety. Whether for industrial or commercial use, it stands out as a dependable choice for protecting electric motors. Its robust design, ease of installation, and superior performance make it a valuable asset in any electrical setup.

Frequently Asked Questions (FAQs)

  1. What is the primary function of the Schneider LR2K0316?
    • It protects electric motors from overloads and phase failures, ensuring safe operation.
  2. Can the LR2K0316 be used in harsh environmental conditions?
    • Yes, it is designed to operate reliably in a wide range of temperatures and conditions.
  3. How often should the LR2K0316 be maintained?
    • Regular maintenance every six months is recommended to ensure optimal performance.
  4. Is the Schneider LR2K0316 energy efficient?
    • Absolutely, it helps in reducing energy wastage by ensuring motors operate within safe limits.
  5. Where can I purchase the Schneider LR2K0316?
    • It is available through authorized Schneider Electric distributors, online retailers, and electrical supply stores.

SKU: LR2K0316 Category: Brand:
Main
RangeTeSys
Product nameTeSys LRK
Product or Component TypeDifferential thermal overload relay
Device short nameLR2K
Relay applicationMotor protection
Product CompatibilityLC7K
LP1K
LC1K
LP4K
Network typeDC
AC
Thermal overload classClass 10A IEC 60947-4-1
Thermal protection adjustment range8…11.5 A
[Ui] rated insulation voltagePower circuit 690 V BS 4941
Power circuit 690 V IEC 60947
Power circuit 750 V VDE 0110 group C
Power circuit 600 V CSA C22.2 No 14
Complementary
Network Frequency<= 400 Hz
Mounting supportUnder contactor
Plate, with specific accessories
Rail, with specific accessories
Auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal current6 A signalling circuit
[Ue] rated operational voltage<= 690 V power circuit
690 V AC AC-15 signalling circuit
250 V DC DC-13 signalling circuit
Associated fuse rating6 A gG for signalling circuit conforming to VDE 0660
6 A gG for signalling circuit conforming to IEC 60947
[Uimp] rated impulse withstand voltage6 kV
Power dissipation per pole2 W
Phase failure sensitivityYes IEC 60947-4-1
Local signallingTrip indicator Yellow)
Control typeRed push-button trip test function
Blue push-button stop and manual reset
selector switch manual or automatic reset
Connections – terminalsScrew clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid
screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid
screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end
screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end
Tightening torque11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2
11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm
11.51 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2
Height2.28 in (58 mm)
Width1.77 in (45 mm)
Depth2.56 in (65 mm)
Net Weight0.32 lb(US) (0.145 kg)
Environment
StandardsIEC 60947
VDE 0660
BS 4941
NF C 63-650
Product CertificationsUL
CSA
UKCA
Protective treatmentTC IEC 60068
TC DIN 50016
IP degree of protectionIP2X conforming to IEC 60529
Ambient air temperature for operation-4…131 °F (-20…55 °C) without derating IEC 60947
-22…140 °F (-30…60 °C) with derating IEC 60947
Ambient Air Temperature for Storage-40…158 °F (-40…70 °C)
Operating altitude6561.68 ft (2000 m) without derating
Fire resistance1562 °F (850 °C) IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Mechanical robustnessShocks NO contact10 Gn for 11 ms IEC 60068-2-27
Shocks NC contact10 Gn for 11 ms IEC 60068-2-27
Vibrations NO contact2 Gn, 5…300 Hz IEC 60068-2-6
Vibrations NC contact2 Gn, 5…300 Hz IEC 60068-2-6
Ordering and shipping details
CategoryUS10I1222324
Discount Schedule0I12
GTIN3389110230581
ReturnabilityYes
Country of originUS
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.83 in (7.200 cm)
Package 1 Width1.89 in (4.800 cm)
Package 1 Length3.35 in (8.500 cm)
Package 1 Weight5.54 oz (157.000 g)
Unit Type of Package 2S02
Number of Units in Package 241
Package 2 Height5.91 in (15.000 cm)
Package 2 Width11.81 in (30.000 cm)
Package 2 Length15.75 in (40.000 cm)
Package 2 Weight15.11 lb(US) (6.855 kg)
Contractual warranty
Warranty18 months

Main Document

Data Sheet : LR2K0316

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LR2K0316 | Diferential thermal overload relays, TeSys K, 8 to 11.5 A, class 10A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat