Let's Chat
-45%

Schneider LR9D5367 | TeSys LRD thermal overload relays – 60…100 A – class 10

Schneider Electric
Availability:

Out of stock


14,540 EGP 26,437 EGP

Out of stock

Compare

Schneider LR9D5367 | TeSys LRD thermal overload relays – 60…100 A – class 10

Schneider LR9D5367 Description

Introduction

When it comes to industrial automation and control solutions, the name Schneider Electric stands out prominently. Among their extensive range of products, the Schneider LR9D5367 holds a special place. But what exactly is the Schneider LR9D5367, and why is it so significant in industrial applications? Let’s dive deep into understanding this crucial component.

Overview of Schneider Electric

Brief History

Schneider Electric, a global leader in energy management and automation, has a rich history dating back to 1836. Over the years, the company has evolved, focusing on innovation and sustainability to provide advanced technological solutions.

Range of Products

Schneider Electric offers a diverse range of products, including circuit breakers, motor starters, relays, and much more. Their commitment to delivering quality and innovative solutions has cemented their reputation in the industry.

Commitment to Quality and Innovation

Schneider Electric’s dedication to quality and innovation is evident in their extensive research and development efforts. They continuously strive to improve their products, ensuring they meet the highest standards of performance and reliability.

Understanding the LR9D5367

Product Classification

The Schneider LR9D5367 is a thermal overload relay, a critical component used to protect electric motors from overheating and damage. It is designed to work seamlessly with contactors, ensuring optimal performance and safety.

Key Features

  • Adjustable Trip Class: Allows for flexibility in setting the desired protection level.
  • Wide Range of Operating Currents: Suitable for various applications.
  • Compact Design: Easy to integrate into existing systems.
  • Manual and Automatic Reset: Provides convenience and versatility in operations.

Technical Specifications

Voltage Rating

The Schneider LR9D5367 operates efficiently within a specified voltage range, ensuring compatibility with different electrical systems.

Current Rating

It is designed to handle a broad range of currents, making it versatile for different motor sizes and applications.

Frequency Range

The LR9D5367 is built to operate across various frequency ranges, ensuring reliability in diverse environments.

Design and Build

Materials Used

Constructed from high-quality materials, the Schneider LR9D5367 is built to last. Its robust design ensures it can withstand harsh industrial conditions.

Durability and Longevity

With its durable build, the LR9D5367 promises long service life, reducing the need for frequent replacements and maintenance.

Operational Mechanism

How Does It Work?

The thermal overload relay works by measuring the heat generated by the motor’s current flow. When the heat exceeds a certain threshold, it trips the relay, cutting off power to prevent damage.

Integration with Other Systems

The LR9D5367 is designed to integrate seamlessly with Schneider’s contactors and other control systems, providing a cohesive and efficient setup.

Applications

Industrial Usage

In industries, the Schneider LR9D5367 is widely used to protect motors driving machinery, conveyors, pumps, and compressors.

Commercial Applications

Beyond industrial use, it finds applications in commercial settings where reliable motor protection is crucial.

Specific Use Cases

From HVAC systems to water treatment plants, the LR9D5367 ensures motors operate safely and efficiently across various use cases.

Installation and Setup

Step-by-Step Guide

  1. Turn Off Power: Ensure all power sources are turned off before starting the installation.
  2. Mount the Relay: Securely mount the LR9D5367 in the designated panel or enclosure.
  3. Connect Wires: Follow the wiring diagram to connect the relay to the motor and contactor.
  4. Set Parameters: Adjust the trip settings according to the motor’s specifications.
  5. Test the Setup: After installation, test the relay to ensure it functions correctly.

Safety Precautions

Always follow safety guidelines to prevent accidents during installation. Wear protective gear and double-check connections.

Tools Required

Basic tools like screwdrivers, pliers, and a multimeter are essential for the installation process.

Maintenance Tips

Routine Checks

Regularly inspect the relay for signs of wear and tear. Ensure all connections are secure and the settings are correct.

Troubleshooting Common Issues

If the relay trips frequently, check for potential issues like overloading, incorrect settings, or faulty wiring.

Extending Product Life

Keep the relay clean and free from dust and debris. Periodically test its functionality to ensure it remains in good working condition.

Advantages of Using Schneider LR9D5367

Efficiency

The LR9D5367 provides efficient protection, minimizing downtime and maximizing productivity.

Reliability

Known for its reliability, this relay ensures consistent performance even under demanding conditions.

Cost-Effectiveness

By preventing motor damage, the LR9D5367 helps reduce repair and replacement costs, offering long-term savings.

Comparison with Competitors

Market Alternatives

While there are other thermal overload relays available, the Schneider LR9D5367 stands out due to its superior build quality and performance.

Why Choose Schneider?

Schneider Electric’s reputation for quality and innovation makes their products, including the LR9D5367, a trusted choice for professionals worldwide.

User Testimonials

Case Studies

In various industries, the LR9D5367 has proven its worth. For instance, a manufacturing plant reported a significant reduction in motor failures after switching to this relay.

User Reviews and Feedback

Users consistently praise the LR9D5367 for its reliability and ease of use, highlighting its role in improving operational efficiency.

Purchasing the LR9D5367

Where to Buy

The Schneider LR9D5367 is available through authorized distributors, online retailers, and directly from Schneider Electric.

Price Range

While prices may vary, investing in a high-quality relay like the LR9D5367 is a cost-effective choice in the long run.

Warranty and Support

Schneider Electric offers robust customer support and warranty options, ensuring peace of mind with your purchase.

Conclusion

In conclusion, the Schneider LR9D5367 thermal overload relay is a vital component for protecting electric motors in various applications. Its robust design, reliability, and ease of use make it a top choice for industrial and commercial settings. By investing in the LR9D5367, you are ensuring the longevity and efficiency of your motor systems.

SKU: LR9D5367 Category:
Main
Range TeSys
Product name TeSys LRD
TeSys Deca
Product or component type Electronic thermal overload relay
Device short name LR9D
Relay application Motor protection
Product compatibility LC1D115
LC1D150
NSX circuit breaker
Network type AC
Thermal overload class Class 10 conforming to IEC 60947-4-1
Signalling function Alarm
Thermal protection adjustment range 60…100 A
[Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Complementary
Network frequency 50…60 Hz
[Us] rated supply voltage 24 V DC
Supply voltage limits 17…32 V
Mounting support Under contactor
Rail
Tripping threshold 1.05 +/- 0.06 In alarm conforming to IEC 60947-4-1
1.12 +/- 0.06 In de-energisation conforming to IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A for signalling circuit
[Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Phase failure sensitivity Tripping in 4 s +/- 20 % conforming to IEC 60947-4-1
Control type Red push-button: stop
Blue push-button: reset
Temperature compensation -20…60 °C
Switching capacity in mA 0…150 mA
Maximum voltage drop <2.5 V closed state
Connections – terminals Power circuit: bars
Control circuit: screw clamp terminals 1 cable(s) 0.5…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 0.5…1.5 mm² flexible without cable end
Alarm circuit: screw clamp terminals 1 cable(s) 0.5…1.5 mm² flexible without cable end
Tightening torque Alarm circuit: 0.45 N.m – on screw clamp terminals
Power circuit: 18 N.m – on bars M8
Control circuit: 1.2 N.m – on screw clamp terminals
height 118 mm
Width 115 mm
Depth 125 mm
Net weight 0.885 kg
Environment
Climatic withstand Conforming to IACS E10
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage -60…70 °C
Operating altitude <= 2000 m without derating
Mechanical robustness Vibrations: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Shocks: 13 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
product certifications UL
CSA
CCC
UKCA
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.0 cm
Package 1 Width 16.0 cm
Package 1 Length 13.0 cm
Package 1 Weight 934.0 g
Unit Type of Package 2 S04
Number of Units in Package 2 12
Package 2 Height 30.0 cm
Package 2 Width 40.0 cm
Package 2 Length 60.0 cm
Package 2 Weight 11.978 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LR9D5367

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LR9D5367 | TeSys LRD thermal overload relays – 60…100 A – class 10”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024