Let's Chat
-45%

Schneider LR9F7575 | TeSys LRF – electronic thermal overload relay – 200…330 A – class 20

Schneider Electric
Availability:

In stock


28,666 EGP 52,121 EGP

In stock

Compare

Schneider LR9F7575 | TeSys LRF – electronic thermal overload relay – 200…330 A – class 20

Schneider LR9F7575: A Comprehensive Description

Introduction

  • Understanding the importance of Schneider LR9F7575
  • Brief overview of Schneider LR9F7575

What is Schneider LR9F7575?

  • Definition and basic features
  • Importance in industrial settings
  • TeSys LR9F electronic overload relay, thermal setting range 200-330A, class 20, for protection of motors 132-160kW@400V. to be mounted directly below a TeSys F 3-pole contactor LC1 F225, F265, F330, F400, F500, use of a support mounting plate LA7F902 is mandatory (to be ordered separately). Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions. On the front of the relay, it provides a thermal adjustement dial, buttons for test, stop & reset, a trip indicator, trip auxiliary contacts 1NO+1NC. Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs/Reach)

Key Features

1. Design and Construction

  • Detailed description of its physical appearance
  • Material used in its construction

2. Functionality

  • Explanation of its primary functions
  • How it operates within a system

3. Compatibility

  • Compatibility with different systems and machinery
  • Integration options

Applications

1. Industrial Automation

  • Role in automation processes
  • Examples of industries where it’s utilized

2. Electrical Control

  • How it aids in electrical control systems
  • Advantages over other alternatives

Benefits of Schneider LR9F7575

  • Increased efficiency in operations
  • Cost-effectiveness compared to alternatives
  • Reliability and durability

Installation and Maintenance

1. Installation Process

  • Step-by-step guide to installing Schneider LR9F7575
  • Necessary precautions

2. Maintenance Requirements

  • Tips for ensuring longevity
  • Common maintenance issues and how to address them

Comparison with Similar Products

  • Contrasting features with other Schneider products
  • Differentiating factors

Cost Analysis

  • Price breakdown and comparison
  • Long-term cost savings

Customer Reviews and Testimonials

  • Feedback from users in various industries
  • Positive experiences and recommendations

Future Developments

  • Potential advancements in Schneider LR9F7575 technology
  • Predictions for its future in industrial settings

Conclusion

  • Recap of Schneider LR9F7575’s significance
  • Encouragement for further exploration and implementation

FAQs

1. Is Schneider LR9F7575 suitable for small-scale industries?

  • Yes, it can be adapted to suit various industrial needs.

2. Can I install Schneider LR9F7575 myself?

  • While it’s possible, it’s recommended to seek professional assistance for proper installation.

3. How long does Schneider LR9F7575 typically last?

  • With proper maintenance, it can last for many years without significant issues.

4. Is Schneider LR9F7575 compatible with other Schneider products?

  • Yes, it’s designed to integrate seamlessly with other Schneider components.

5. What sets Schneider LR9F7575 apart from its competitors?

  • Its robust design, reliability, and wide range of applications make it a preferred choice among industrial professionals.
SKU: LR9F7575 Category:
Main
Range TeSys
Product name TeSys LRF
Device short name LR9F
Product or Component Type Electronic thermal overload relay
Relay application Motor protection
Product Compatibility LC1F225…LC1F500
Network type AC
Thermal overload class Class 20 IEC 60947-4
Thermal protection adjustment range 200…330 A
Complementary
Network Frequency 50/60 Hz
Mounting support Direct on contactor
Plate
Tripping threshold 1.12 +/- 0.06 In tripping IEC 60947-4-1
Surge withstand 4 kV IEC 61000-4-5
Contacts type and composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A control circuit
[Ue] rated operational voltage 1000 V AC 50/60 Hz power circuit VDE 0110 group C
[Ui] rated insulation voltage Power circuit 1000 V AC IEC 60947-4
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-1
Phase failure sensitivity Tripping in 4 s +/- 20 % IEC 60947-4-1
Reset Manual reset on front relay
Control type Dial White full-load current adjustment
Test button Red
Push-button Red reset
Push-button stop
local signalling Trip indicator
Temperature compensation -4…158 °F (-20…70 °C)
Current consumption <= 5 mA no-load
switching capacity for alarm 0…150 mA
Maximum voltage drop <2.5 V closed state
Connections – terminals Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²) flexible – with cable end
Control circuit screw clamp terminals 1 0.00…0.00 in² (0.75…2.5 mm²) solid
Control circuit screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²) flexible – without cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…1.5 mm²) flexible – with cable end
Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible – without cable end
Control circuit screw clamp terminals 2 0.00 in² (1 mm²) solid
Power circuit lugs-ring terminals M10
Tightening torque Control circuit 1.2 N.m screw clamp terminals
Power circuit 35 N.m screw clamp terminals
Height 5.39 in (136.8 mm)
Width 5.91 in (150 mm)
Depth 5.02 in (127.6 mm)
Net Weight 5.11 lb(US) (2.32 kg)
Environment
Standards IEC 60255-8
VDE 0660
IEC 60255-17
EN 60947-4-1
IEC 60947-4-1
Product Certifications CSA
UL
UKCA
Protective treatment TH
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to VDE 0106
Ambient air temperature for operation -4…131 °F (-20…55 °C) IEC 60255-8
Ambient Air Temperature for Storage -40…185 °F (-40…85 °C)
Operating altitude <= 6561.68 ft (2000 m) without derating
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Mechanical robustness Shocks13 Gn for 11 ms IEC 60068-2-7
Vibrations 5…300 Hz2 GN IEC 60068-2-6
Dielectric strength 6 kV 50 Hz IEC 255-5
Electromagnetic compatibility Resistance to electrostatic discharge 6 kV in indirect mode IEC 61000-4-2
Resistance to electrostatic discharge 8 kV in air IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test 10 V/m IEC 61000-4-3
Fast transients immunity test 2 kV IEC 61000-4-4
Ordering and shipping details
Category US10I1222334
Discount Schedule 0I12
GTIN 3389110640212
Returnability No
Country of origin FR
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 6.77 in (17.2 cm)
Package 1 Width 7.09 in (18.0 cm)
Package 1 Length 10.24 in (26.0 cm)
Package 1 Weight 4.15 lb(US) (1.884 kg)
Unit Type of Package 2 S04
Number of Units in Package 2 6
Package 2 Height 11.81 in (30.0 cm)
Package 2 Width 15.75 in (40.0 cm)
Package 2 Length 23.62 in (60.0 cm)
Package 2 Weight 26.77 lb(US) (12.144 kg)
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LR9F7575

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LR9F7575 | TeSys LRF – electronic thermal overload relay – 200…330 A – class 20”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024