-48%
, , ,

Schneider LR9G225 | Electronic thermal overload relay,TeSys Giga,57-225 A,class 5E-30E,push-in control connection

Schneider Electric

Schneider LR9G225 | Electronic thermal overload relay,TeSys Giga,57-225 A,class 5E-30E,push-in control connection

16,504 EGP 31,738 EGP

Compare

Schneider LR9G225 | Electronic thermal overload relay,TeSys Giga,57-225 A,class 5E-30E,push-in control connection

The Schneider LR9G225 is a high-performance electronic thermal overload relay from the TeSys Giga series, designed to provide precise and reliable protection for motors against thermal overload and phase imbalance. With a current range of 57 to 225 A and an adjustable class 5E-30E time delay, this relay ensures optimal motor performance and longevity. Its push-in control connection technology simplifies installation, making it a perfect choice for industrial applications that require efficient and secure motor protection.

Technical Specifications

  • Model: LR9G225
  • Brand: Schneider Electric
  • Type: Electronic Thermal Overload Relay
  • Current Range: 57 to 225 A
  • Time Delay Class: Class 5E-30E (adjustable)
  • Control Connection: Push-in terminals for easy and quick installation
  • Mounting: Designed for seamless integration with TeSys Giga contactors
  • Voltage Rating: Compatible with 3-phase AC motors
  • Protection Features: Overload protection, phase imbalance detection, and automatic/manual reset options
  • Digital Display: Allows for easy monitoring and setting adjustments

Key Features

  1. Wide Current Range (57-225 A) – Supports a broad range of motor sizes, making it suitable for various industrial applications.
  2. Precise Motor Protection – Offers accurate monitoring and protection against thermal overload, phase imbalance, and abnormal current conditions.
  3. Class 5E-30E Adjustable Trip Delay – Allows flexibility in response time to match different motor operating conditions and prevent unnecessary shutdowns.
  4. Push-In Control Connection – Ensures quick and secure wiring, reducing installation time and enhancing reliability.
  5. Integrated Digital Display – Enables real-time monitoring of motor status and easy parameter adjustments.
  6. Durable and Reliable – Designed for harsh industrial environments, ensuring long service life and consistent performance.
  7. Automatic and Manual Reset Options – Provides flexibility in fault recovery, reducing downtime and improving operational efficiency.

Applications

The LR9G225 electronic thermal overload relay is ideal for protecting motors in various industrial and commercial applications, including:

  1. Industrial Motor Control – Ensures smooth and safe operation of motors in factories and production plants.
  2. Pumps and Compressors – Protects motors in water treatment plants, chemical industries, and air compression systems.
  3. HVAC Systems – Ideal for safeguarding motors in heating, ventilation, and air conditioning units.
  4. Conveyor Systems – Prevents motor failures in automated material handling and logistics operations.
  5. Cranes and Hoists – Provides thermal protection for motors used in lifting and heavy-load applications.
  6. Automation Systems – Ensures uninterrupted operation of automated machinery by preventing overheating and motor failures.
brands

Main
RangeTeSys
product nameTeSys LRG
Product or component typeElectronic thermal overload relay
Device short nameLR9G
Relay applicationMotor protection
network typeAC
Thermal overload classClass 5E…30E conforming to IEC 60947-4-1
Thermal protection adjustment range57…225 A
Complementary
Network frequency30…60 Hz
100 Hz
overvoltage categoryIII
Tripping threshold1.125 +/- 0.07 In conforming to IEC 60947-4-1
Protection typeGround fault protection – tripping time adjustment: 0…1 s – for alarm circuit conforming to IEC 60947-4-1
Ground fault protection – tripping time adjustment: 0…1 s – for alarm circuit conforming to UL 60947-4-1
Phase loss – tripping time adjustment: 0…4 s – for alarm circuit
Phase imbalance – tripping time adjustment: 0…5 s – for alarm circuit conforming to IEC 60947-4-1
Phase imbalance – tripping time adjustment: 0…5 s – for alarm circuit conforming to UL 60947-4-1
Local signallingLED
Trip indicator
Contacts type and composition1 NO + 1 NC
[Ith] conventional free air thermal current5 A
[Uc] control circuit voltage24…500 V AC 50/60 Hz
24…250 V DC
[Ue] rated operational voltage1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
ResetAutomatic reset
Manual
Mechanical durability7000 cycles
Surge withstand4 kV
Electromagnetic compatibilityEMC immunity conforming to IEC 60947-4-1
Emission tests criteria A conforming to IEC 60947-4-1
Immunity to radiated radio-electrical interference – test level: 20 V/m conforming to EN/IEC 61000-4-3
Voltage dips and interruptions immunity test conforming to SEMI F47
Connections – terminalsPower circuit: bar – busbar cross section: 25 x 6 mm
Power circuit: lugs-ring terminals 1 185 mm²
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Tightening torque18 N.m
Mounting supportDirect on contactor
Plate
StandardsEN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
UL 60335-1
Product certificationsCB Scheme
CCC
cULus
UKCA
ATEX
EU-RO-MR by DNV-GL
EAC
Environment
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Protective treatmentTH
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-60…80 °C
Permissible ambient air temperature around the device-40…60 °C at Uc
Adjustment of dial setting-25…60 °C
Mechanical robustnessVibrations 5…300 Hz 6 gn contactor open
Shocks 15 gn 11 ms contactor closed
Height107 mm
Width105 mm
Depth126 mm
Product weight0.9 kg
ColourDark grey
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height17.000 cm
Package 1 Width20.000 cm
Package 1 Length21.000 cm
Package 1 Weight1.406 kg
Unit Type of Package 2S03
Number of Units in Package 22
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight3.383 kg
Unit Type of Package 3P06
Number of Units in Package 316
Package 3 Height75.000 cm
Package 3 Width60.000 cm
Package 3 Length80.000 cm
Package 3 Weight35.624 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LR9G225 | Electronic thermal overload relay,TeSys Giga,57-225 A,class 5E-30E,push-in control connection”

There are no reviews yet.

SHOPPING CART