Let's Chat
-46%

Schneider LRD05 | TeSys LRD thermal overload relays – 0.63…1 A – class 10A

Schneider Electric
Availability:

In stock


2,024 EGP 3,748 EGP

In stock

Compare

Schneider LRD05| TeSys LRD thermal overload relays – 0.63…1 A – class 10A

Schneider LRD05 Description

Schneider LRD05: The Complete Overview of a Reliable Motor Protection Relay

1. Introduction to Schneider LRD05

The Schneider LRD05 is a motor protection relay designed to safeguard industrial motors against overload conditions. It serves as a vital component in ensuring the smooth and safe operation of machinery, preventing damage and downtime.

2. Technical Specifications

Voltage and Current Ratings

The LRD05 relay is suitable for motor currents ranging from 0.1A to 65A and operates at voltages up to 690V AC.

Trip Class

It adheres to Class 10 trip characteristics, providing fast and reliable protection against overloads.

Trip Curve

With its advanced trip curve, the Schneider LRD05 offers precise and consistent tripping performance, adapting to various load conditions.

Ambient Temperature Range

The relay can function within a temperature range of -25°C to +70°C, making it suitable for a wide range of operating environments.

3. Features and Benefits

Overload Protection

Equipped with sophisticated algorithms, the LRD05 accurately detects overload conditions and initiates timely protective measures, preventing motor damage.

Trip Indication

The relay provides clear visual and audible indicators upon tripping, facilitating prompt diagnosis and troubleshooting.

Compact Design

Its compact and ergonomic design allows for easy integration into control panels and limited-space installations, ensuring versatility and convenience.

4. Applications

Industrial Machinery

The Schneider LRD05 finds extensive usage in various industrial applications, including pumps, compressors, conveyors, and more, offering reliable motor protection.

HVAC Systems

In heating, ventilation, and air conditioning systems, the relay ensures the uninterrupted operation of motors, enhancing efficiency and longevity.

Control Panels

Integrated into control panels, the LRD05 contributes to the overall safety and performance of electrical systems, minimizing downtime and maintenance costs.

5. Installation and Usage

Mounting Options

The relay supports both DIN rail and screw mounting options, providing flexibility in installation according to specific requirements.

Wiring Procedures

Installation and wiring are straightforward, with clearly labeled terminals and comprehensive user manuals provided by Schneider Electric.

Setting the Trip Point

Users can easily adjust the trip point of the relay to match the rated current of the connected motor, ensuring optimal protection and performance.

6. Maintenance and Troubleshooting

Inspection Guidelines

Regular inspection and maintenance are recommended to ensure the continued reliability and effectiveness of the LRD05 relay. Visual checks for signs of wear or damage, along with functional tests, are essential.

Common Issues and Solutions

Common issues such as false tripping or inadequate protection can often be resolved through proper calibration or adjustment of the relay settings, as outlined in the user manual.

7. Comparisons with Other Relays

The Schneider LRD05 stands out among its competitors due to its superior performance, robust construction, and extensive range of features, making it the preferred choice for motor protection applications.

8. Customer Reviews and Testimonials

Customer feedback consistently highlights the reliability, durability, and ease of use of the Schneider LRD05 relay, reaffirming its position as a trusted solution in the industry.

9. Conclusion

In conclusion, the Schneider LRD05 motor protection relay offers unmatched reliability, performance, and versatility, making it an indispensable asset for industrial applications. With its advanced features, compact design, and ease of installation, it provides comprehensive protection for motors while enhancing operational efficiency and reducing downtime.

Main
Range TeSys
TeSys Deca
Product name TeSys LRD
TeSys Deca
Product or component type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product compatibility LC1D25
LC1D38
LC1D12
LC1D32
LC1D18
LC1D09
Network type AC
DC
Thermal overload class Class 10A conforming to IEC 60947-4-1
Thermal protection adjustment range 0.63…1 A
[Ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1
Complementary
Network frequency 0…400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A for signalling circuit
Permissible current 3 A at 120 V AC-15 for signalling circuit
0.22 A at 125 V DC-13 for signalling circuit
[Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button: stop
Blue push-button: reset
Temperature compensation -20…60 °C
Connections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 1.7 N.m – on screw clamp terminals
Height 66 mm
Width 45 mm
Depth 70 mm
Net weight 0.124 kg
Environment
Climatic withstand conforming to IACS E10
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage -60…70 °C
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495
Product certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCA
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5 cm
Package 1 Width 7.8 cm
Package 1 Length 8.9 cm
Package 1 Weight 139 g
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 3.767 kg
Unit Type of Package 3 P06
Number of Units in Package 3 384
Package 3 Height 80 cm
Package 3 Width 80 cm
Package 3 Length 60 cm
Package 3 Weight 68.388 kg
Contractual warranty
Warranty 18 months

Main documents

Datasheet Download Datasheet
Product datasheet LRD05 
User guide
Download
Instruction sheet
Download
Catalogue
Download
CAD Files Download
Environmental disclosure
Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LRD05 | TeSys LRD thermal overload relays – 0.63…1 A – class 10A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024