Let's Chat
-46%

Schneider LRD07 | TeSys LRD thermal overload relays – 1.6…2.5 A – class 10A

Schneider Electric
Availability:

In stock


2,024 EGP 3,748 EGP

In stock

Compare

Schneider LRD07| TeSys LRD thermal overload relays – 1.6…2.5 A – class 10A

Schneider LRD07 Description

it is a versatile and efficient thermal overload relay designed to protect electrical motors from overheating and overload conditions. With its advanced features and reliable performance, it has become a preferred choice for various industrial and commercial applications. Let’s delve into the details of this remarkable product.

Introduction to Schneider LRD07

it is a part of the TeSys series of thermal overload relays manufactured by Schneider Electric, a global leader in energy management and automation solutions. It is engineered to provide optimal motor protection and ensure the smooth operation of electrical systems in diverse environments.

Key Features 

  • Precise Overload Protection: The LRD07 offers precise protection against motor overload conditions, preventing damage and downtime.
  • Adjustable Current Settings: Users can easily adjust the current settings according to the specific requirements of their applications.
  • Compact Design: With its compact and ergonomic design, the LRD07 can be seamlessly integrated into motor control panels and switchboards.
  • High Durability: Built to withstand harsh industrial environments, the LRD07 is highly durable and resistant to wear and tear.
  • Easy Installation: The relay features simple wiring and mounting options, facilitating quick and hassle-free installation.

Technical Specifications

Size and Dimensions

  • Dimensions: 45mm x 97mm x 76mm
  • Weight: 0.25 kg

Operating Voltage

  • Rated Operational Voltage (Ue): 690 V
  • Rated Insulation Voltage (Ui): 690 V
  • Frequency: 50/60 Hz

Control Features

  • Trip Class: Class 10
  • Reset Method: Automatic/Manual
  • Contact Configuration: 1 NO + 1 NC

Applications 

it finds wide-ranging applications across various industries, including:

  • Industrial Machinery: It is used in pumps, compressors, conveyors, and other types of industrial machinery to protect motors from overload conditions.
  • HVAC Systems: The LRD07 ensures reliable operation and protection of motors in heating, ventilation, and air conditioning (HVAC) systems.
  • Motor Control Panels: It is commonly installed in motor control panels to provide effective overload protection and enhance system performance.

Installation Guide

Installing it is a straightforward process. Here are some basic guidelines:

Wiring Instructions

  • Ensure proper sizing of cables based on the motor’s current rating.
  • Connect the relay in series with the motor circuit, following the manufacturer’s wiring diagram.
  • Verify the polarity and tightness of connections to prevent electrical faults.

Mounting Options

  • The relay can be mounted on a standard DIN rail or directly onto a panel surface.
  • Ensure adequate ventilation around the relay for optimal heat dissipation.

Benefits 

  • Overload Protection: The LRD07 offers reliable protection against motor overload conditions, preventing costly damage and downtime.
  • Energy Efficiency: By preventing motor overheating, the relay helps conserve energy and improve system efficiency.
  • Reliability: Schneider Electric is known for its quality and reliability, ensuring that the LRD07 delivers consistent performance in demanding environments.

Comparison with Similar Products

Compared to other thermal overload relays on the market, it stands out for its robust construction, precise protection features, and ease of installation. It offers exceptional value for money and peace of mind to users.

Maintenance Tips

To ensure optimal performance and longevity of it, follow these maintenance tips:

  • Regularly inspect the relay for signs of wear or damage.
  • Keep the surrounding area clean and free from dust or debris.
  • Test the functionality of the relay periodically to ensure it responds accurately to overload conditions.

Troubleshooting Common Issues

  • Issue: Motor tripping frequently.
    • Solution: Check for loose connections or faulty wiring. Adjust the current settings if necessary.
  • Issue: Relay not resetting automatically.
    • Solution: Verify the reset method setting and ensure it is configured correctly.
    • Pricing Information

The price of it varies depending on the supplier and quantity purchased. It is advisable to request a quote from authorized distributors for accurate pricing information.

Where to Buy Schneider LRD07

it is available through authorized distributors and retailers worldwide. Customers can also purchase it online from reputable suppliers.

Warranty Details

Schneider Electric offers a standard warranty on LRD07, covering manufacturing defects and faulty materials. Extended warranty options may be available for additional peace of mind.

Conclusion

In conclusion, it is a reliable and efficient thermal overload relay that offers superior motor protection and performance. With its advanced features, durable construction, and ease of installation, it is an ideal choice for various industrial and commercial applications.

Main
Range TeSys
TeSys Deca
Product name TeSys LRD
TeSys Deca
Product or component type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product compatibility LC1D18
LC1D38
LC1D32
LC1D25
LC1D12
LC1D09
Network type DC
AC
Thermal overload class Class 10A conforming to IEC 60947-4-1
Thermal protection adjustment range 1.6…2.5 A
[Ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1
Complementary
Network frequency 0…400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A for signalling circuit
Permissible current 3 A at 120 V AC-15 for signalling circuit
0.22 A at 125 V DC-13 for signalling circuit
[Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button: stop
Blue push-button: reset
Temperature compensation -20…60 °C
Connections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 1.7 N.m – on screw clamp terminals
Height 66 mm
Width 45 mm
Depth 70 mm
Net weight 0.124 kg
Environment
Climatic withstand conforming to IACS E10
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage -60…70 °C
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495
Product certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCA
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.800 cm
Package 1 Width 7.700 cm
Package 1 Length 4.900 cm
Package 1 Weight 138.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 3.653 kg
Unit Type of Package 3 P06
Number of Units in Package 3 384
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 72.827 kg
Contractual warranty
Warranty 18 months

Main documents

Datasheet Download Datasheet
Product datasheet Download
User guide
Download
Instruction sheet
Download
Catalogue
Download
CAD Files Download
Environmental disclosure
Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LRD07 | TeSys LRD thermal overload relays – 1.6…2.5 A – class 10A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024