LRD3365 | TeSys LRD thermal overload relays – 80…104 A – class 10A

5,617 EGP 10,403 EGP

In stock

Compare

Schneider LRD3365 | TeSys LRD thermal overload relays – 80…104 A – class 10A

The Schneider LRD3365 is a high-performance thermal overload relay designed for effective motor protection. As part of Schneider Electric’s renowned TeSys range, this relay ensures reliability, precision, and safety in motor control applications. Its advanced features make it a trusted choice for industrial and commercial environments.

Key Features

  1. Current Adjustment Range:
    • Adjustable between 23 to 32A, allowing for tailored protection for different motor capacities.
  2. Trip Class:
    • Offers Class 10A tripping characteristics, ensuring fast and effective response to overloads.
  3. Overload and Phase Failure Protection:
    • Safeguards motors against overheating, phase loss, and imbalance, minimizing the risk of damage.
  4. Manual and Automatic Reset Options:
    • Flexibility to switch between manual and automatic reset modes based on operational requirements.
  5. Compact and Modular Design:
    • Compatible with TeSys D contactors for streamlined integration into motor control systems.
  6. Test and Stop Buttons:
    • Facilitates easy testing and manual stopping of the motor for maintenance and troubleshooting.

Applications

The LRD3365 is ideal for a wide array of motor protection applications, such as:

  • Industrial Equipment:
    Protection for motors in conveyor systems, compressors, and machine tools.
  • HVAC Systems:
    Ensures uninterrupted operation of fans and pumps in heating, ventilation, and cooling systems.
  • Automated Systems:
    A critical component in automation processes requiring reliable motor control and protection.

Benefits

  1. Superior Protection:
    Prevents damage to motors by detecting and addressing overload conditions promptly.
  2. Versatile Use:
    Accommodates motors across various industries with its adjustable current range.
  3. Energy Efficiency:
    Reduces unnecessary tripping, optimizing motor operation and system uptime.
  4. Ease of Integration:
    Designed to pair seamlessly with Schneider’s contactors for a compact, unified solution.

Technical Specifications

Specification Details
Current Adjustment Range 23 – 32A
Trip Class 10A
Reset Options Manual/Automatic
Phase Failure Sensitivity Yes
Standards IEC 60947-4-1
Operating Temperature -20°C to +60°C

Installation and Maintenance

  • Installation:
    Mounts directly onto TeSys D contactors or can be standalone panel-mounted.
  • Connection:
    Clear terminal markings simplify wiring.
  • Testing and Maintenance:
    Test functionality periodically using the built-in test button to ensure reliable operation.
Main
Range TeSys
Product name TeSys LRD
TeSys Deca
Product or component type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product compatibility LC1D95
LC1D80
Network type AC
DC
Thermal overload class Class 10A conforming to IEC 60947-4-1
Thermal protection adjustment range 80…104 A
[Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Complementary
Network frequency 0…400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A for signalling circuit
Permissible current 0.72 A at 500 V AC-15 for signalling circuit
0.06 A at 440 V DC-13 for signalling circuit
[Ue] rated operational voltage 1000 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button: stop
Blue push-button: reset
Temperature compensation -20…60 °C
Connections – terminals Power circuit: screw clamp terminals 1 cable(s) 4…35 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 4…35 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 4…35 mm² solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 9 N.m – on screw clamp terminals
Height 81 mm
Width 70 mm
Depth 115 mm
Net weight 0.51 kg
Environment
Climatic withstand conforming to IACS E10
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage -60…70 °C
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric strength 2.2 kV at 50 Hz conforming to IEC 60947-1
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495
Product certifications IEC
UL
CSA
CCC
EAC
ATEX INERIS
UKCA
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.800 cm
Package 1 Width 12.000 cm
Package 1 Length 8.600 cm
Package 1 Weight 549.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 12
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 6.917 kg
Unit Type of Package 3 P06
Number of Units in Package 3 192
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 122.363 kg
Contractual warranty
Warranty 18 months

Main documents

Datasheet Download Datasheet
Product datasheet LRD3365 
Instruction sheet
Download
Catalogue
Download
CAD Files
Download
Environmental disclosure Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LRD3365 | TeSys LRD thermal overload relays – 80…104 A – class 10A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024