Schneider LRD4367 | TeSys LRD thermal overload relays – 95…120 A – class 10A

Schneider Electric
Availability:

In stock


Schneider LRD4367 | TeSys LRD thermal overload relays – 95…120 A – class 10A

8,545 EGP 15,823 EGP

In stock

Compare

Schneider LRD4367 TeSys:

is a cutting-edge motor overload relay designed to provide optimal protection to industrial machinery. As an essential component in motor control systems, this relay ensures the smooth operation of equipment while safeguarding against electrical overloads and faults. With its advanced features and robust construction, Schneider LRD4367 stands out as a reliable solution for various industrial applications.

Features of Schneider LRD4367

Tripping Class

One of the key features of it is its tripping class, which determines the response time of the relay to an overload condition. This relay is available in different tripping classes to suit specific application requirements, providing flexibility and customization options for users.

Current Rating

it is available in various current ratings, allowing users to select the appropriate relay based on the power requirements of their equipment. Whether it’s low-power machinery or high-current industrial systems, this relay offers a wide range of options to meet diverse needs.

Operating Temperature

With its ability to operate in extreme temperatures, it ensures reliable performance even in harsh environmental conditions. Whether it’s freezing cold or scorching heat, this relay maintains its functionality, providing uninterrupted protection to critical machinery.

Mounting Style

it is designed for easy installation, with multiple mounting options available to accommodate different setup configurations. Whether it’s panel-mounted or DIN rail-mounted, this relay can be easily integrated into existing control systems without hassle.

Applications of Schneider LRD4367

Industrial Machinery

Schneider LRD4367 is widely used in various industrial machinery applications, including pumps, compressors, conveyors, and more. Its ability to detect and respond to overload conditions ensures the safety and reliability of equipment operation, minimizing downtime and maintenance costs.

Motor Protection

As a motor overload relay, Schneider LRD4367 plays a crucial role in protecting electric motors from damage due to overcurrents. By monitoring the motor’s current draw and tripping in case of overload, this relay prevents motor burnout and extends equipment lifespan, saving both time and money for users.

Overload Protection

In addition to motor protection, Schneider LRD4367 also provides overload protection for other electrical components in industrial systems. By interrupting the circuit during overload conditions, this relay prevents damage to sensitive equipment and ensures the safety of personnel working in the vicinity.

Advantages of Using Schneider LRD4367

Reliability

Schneider LRD4367 is known for its reliability and durability, thanks to its robust construction and high-quality components. With a proven track record of performance in demanding industrial environments, this relay offers peace of mind to users, knowing that their equipment is well-protected against electrical faults.

Precision

The precision of Schneider LRD4367 ensures accurate detection and response to overload conditions, minimizing false trips and unnecessary downtime. By providing precise protection to machinery and electrical systems, this relay helps optimize productivity and efficiency in industrial operations.

Safety

Safety is paramount in industrial environments, and Schneider LRD4367 prioritizes it with its advanced safety features and fail-safe operation. By detecting and responding to overload conditions promptly, this relay helps prevent accidents and injuries, ensuring a safe working environment for personnel.

Main
Range TeSys
Product name TeSys LRD
TeSys Deca
Product or component type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product compatibility LC1D150
LC1D115
Network type AC
DC
Thermal overload class Class 10A conforming to IEC 60947-4-1
Thermal protection adjustment range 95…120 A
[Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Complementary
Network frequency 0…400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A for signalling circuit
Permissible current 0.06 A at 440 V DC-13 for signalling circuit
0.12 A at 600 V AC-15 for signalling circuit
[Ue] rated operational voltage 1000 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button: stop
Blue push-button: reset
Temperature compensation -20…60 °C
Connections – terminals Power circuit: screw clamp terminals 1 cable(s) 4…35 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 4…50 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 4…50 mm² solid without cable end
Tightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 9 N.m – on screw clamp terminals
Depth 132 mm
Net weight 0.9 kg
Environment
Climatic withstand conforming to IACS E10
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage -60…70 °C
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
Dielectric strength 2.2 kV at 50 Hz conforming to IEC 60947-1
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495
Product certifications IEC
UL
CSA
CCC
EAC
ATEX INERIS
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.500 cm
Package 1 Width 13.500 cm
Package 1 Length 11.000 cm
Package 1 Weight 839.000 g
Unit Type of Package 2 S03
Number of Units in Package 2 10
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 8.880 kg
Unit Type of Package 3 P06
Number of Units in Package 3 80
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 81.324 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LRD4367

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LRD4367 | TeSys LRD thermal overload relays – 95…120 A – class 10A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024