Schneider LRE482 | Thermal overload relay,Easy TeSys Protect,84…135A,class 10A

The Schneider LRE482 is a high-performance thermal overload relay from the Easy TeSys Protect series, designed to safeguard electric motors from overheating and overload conditions. With an adjustable current range of 84 to 135 A and a Class 10A trip time, this relay ensures optimal motor protection in various industrial applications. It is built for seamless integration with TeSys contactors, providing reliable and efficient motor management.

Technical Specifications

  • Model: LRE482
  • Brand: Schneider Electric
  • Series: Easy TeSys Protect
  • Type: Thermal Overload Relay
  • Current Range: 84 to 135 A (adjustable)
  • Trip Class: Class 10A
  • Mounting: Direct mounting on TeSys contactors
  • Operating Voltage: Suitable for AC motors
  • Reset Mode: Manual and automatic reset options
  • Phase Imbalance Protection: Prevents damage due to unbalanced current conditions
  • Ambient Temperature Compensation: Ensures accurate protection under varying environmental conditions

Key Features

  1. Wide Current Adjustment (84-135A) – Covers a broad range of motor sizes for flexible application.
  2. Class 10A Tripping – Provides quick response to overloads, preventing motor overheating and damage.
  3. Seamless Integration with TeSys Contactors – Ensures easy installation and reliable motor protection.
  4. Automatic & Manual Reset – Offers operational flexibility for different motor protection requirements.
  5. Phase Imbalance Detection – Enhances motor longevity by preventing damage from unbalanced loads.
  6. Compact & Robust Design – Built for industrial environments with high durability and performance.
  7. Energy Efficient – Reduces unnecessary shutdowns while ensuring reliable motor performance.

Applications

The LRE482 thermal overload relay is widely used in industries that require efficient motor protection, including:

  1. Industrial Motor Control – Ensures reliable operation of motors in production and manufacturing plants.
  2. Pumps and Compressors – Protects critical equipment from overload and phase imbalance failures.
  3. HVAC Systems – Ideal for motors used in heating, ventilation, and air conditioning applications.
  4. Conveyor Systems – Prevents motor failures in material handling and logistics operations.
  5. Water Treatment Plants – Provides protection for motors used in pumping and filtration systems.
  6. Heavy Machinery – Ensures motor longevity in mining, construction, and other demanding environments.

 

brands

Schneider Electric

Main
RangeEasy TeSys
Range of productEasy TeSys Protect
Product or component typeDifferential thermal overload relay
Device short nameLRE
Relay applicationMotor protection
Phase failure sensitivityTripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1
Complementary
Product compatibilityLC1E120…630
network typeAC
Network frequency50…60 Hz
Mounting supportUnder contactor
Plate
Thermal overload classClass 10A conforming to IEC 60947-4-1
Signalling functionRelay trip indicator
Thermal protection adjustment range84…135 A
Tripping threshold1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Mechanical robustnessShocks: 6 Gn for 11 ms conforming to IEC 60068-2-7
Vibrations: 3 GN conforming to IEC 60068-2-6
Auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal current5 A for signalling circuit
[Ue] rated operational voltage<= 690 V AC
Associated fuse rating200 A gG for power circuit
160 A aM for power circuit
5 A gG for signalling circuit
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV
Local signallingTrip indicator
Control typePush-button red stop:
Push-button green reset:
Temperature compensation-20…60 °C
Connection pitch34.8 mm
Connections – terminalsSignalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: solid without cable end
Power circuit: bars – busbar cross section: 3 x 18 mm
Power circuit: lugs
Recommended tightening torquePower circuit: 27.5 N.m – on bars M8
Power circuit: 27.5 N.m – on lugs M8
Signalling circuit: 1.7 N.m – on screw clamp terminals
Height141 mm
Width180 mm
Depth134 mm
Product weight2.2 kg
Environment
StandardsIEC 60947-5-1
IEC 60947-4-1
Product certificationsEAC
Protective treatmentTH conforming to IEC 60068
IP degree of protectionIP00 conforming to IEC 60529
Ambient air temperature for operation-20…60 °C without derating conforming to IEC 60947-4-1
-20…70 °C with derating
Ambient air temperature for storage-60…80 °C
Fire resistance850 °C conforming to IEC 60068-2-1
Dielectric strength6 kV at 50 Hz conforming to IEC 60255-5
Electromagnetic compatibilitySurge withstand: 6 kV conforming to IEC 60801-5
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width17.500 cm
Package 1 Length27.300 cm
Package 1 Weight2.861 kg
Unit Type of Package 2S03
Number of Units in Package 22
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6226.000 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : Download

Based on 0 reviews