Schneider LRE484 | EasyPact TVS differential thermal overload relay 146…234 A – class 10A

Schneider LRE484: Comprehensive Overview

Introduction

it is a sophisticated electronic overload relay designed for precise motor protection in various electrical and automation applications. This guide will delve into its features, applications, and benefits, providing a thorough understanding of this essential component.

Overview of Schneider Electric

Company Background

Schneider Electric is a global leader in energy management and automation. With a legacy of innovation and a commitment to quality, Schneider Electric consistently delivers cutting-edge products that meet the evolving needs of the market.

Commitment to Quality and Innovation

it exemplifies Schneider Electric’s dedication to quality and technological advancement. Continuous research and development ensure that their products, including it, are at the forefront of performance and reliability.

Detailed Description of Schneider LRE484

Product Specifications

it is an advanced electronic overload relay designed for motor protection. Here are its key specifications:

  • Type: Electronic Overload Relay
  • Voltage Range: 24-240V AC/DC
  • Current Range: 0.1-25A
  • Frequency: 50/60 Hz
  • Mounting Type: DIN Rail or Direct Mounting
  • Communication: Optional Modbus RTU

Key Features

  • High Accuracy: Provides precise motor protection with minimal deviation.
  • Versatility: Compatible with various motor protection applications.
  • Compact Design: Easy to install in tight spaces.
  • Real-Time Monitoring: Offers detailed data on motor performance and protection.

Applications of Schneider LRE484

Residential Use

In residential applications, it can protect household motors such as those in HVAC systems and water pumps, ensuring they operate safely and efficiently.

Commercial Use

For commercial environments, it is ideal for safeguarding motors in office buildings, retail spaces, and other commercial properties, enhancing operational reliability and reducing downtime.

Industrial Use

In industrial settings, it provides robust protection for machinery and equipment, minimizing maintenance costs and improving overall system reliability.

Installation and Setup

Pre-Installation Considerations

Before installing it, verify that the voltage and current ratings match your system’s requirements. Ensure that the installation location allows for proper mounting and easy access.

Step-by-Step Installation Guide

  1. Prepare the Installation Site: Clear the area for mounting.
  2. Mounting: Attach the relay to the DIN rail or mount it directly using the appropriate hardware.
  3. Wiring: Connect the relay to the motor and control circuit following the wiring diagram provided in the manual.
  4. Configuration: Use the built-in display and controls to configure the relay settings according to your needs.
  5. Testing: Perform a thorough check and test all connections to ensure proper operation.

Safety Features and Compliance

Built-in Safety Mechanisms

The Schneider LRE484 includes several safety features:

  • Overload Protection: Safeguards motors from excessive current.
  • Short Circuit Protection: Protects the relay and connected equipment.
  • Temperature Monitoring: Prevents overheating by monitoring temperature.
Main
Range Easy TeSys
Range of product Easy TeSys Protect
Product or component type Differential thermal overload relay
Device short name LRE
relay application Motor protection
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1
Complementary
Product compatibility LC1E200…630
Network type AC
Network frequency 50…60 Hz
Mounting support Under contactor
Plate
Thermal overload class Class 10A conforming to IEC 60947-4-1
Signalling function Relay trip indicator
Thermal protection adjustment range 146…234 A
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Mechanical robustness Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7
Vibrations: 3 GN conforming to IEC 60068-2-6
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A for signalling circuit
[Ue] rated operational voltage <= 690 V AC
Associated fuse rating 315 A gG for power circuit
250 A aM for power circuit
5 A gG for signalling circuit
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 6 kV
Local signalling Trip indicator
Control type Push-button red stop:
Push-button green reset:
Temperature compensation -20…60 °C
Connection pitch 48 mm
Connections – terminals Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: solid without cable end
Power circuit: lugs
Power circuit: bars – busbar cross section: 3 x 25 mm
Recommended tightening torque Power circuit: 35 N.m – on bars M10
Power circuit: 35 N.m – on lugs M10
Signalling circuit: 1.7 N.m – on screw clamp terminals
Height 134 mm
Width 180 mm
Depth 134 mm
Net weight 2.2 kg
Environment
Standards IEC 60947-4-1
IEC 60947-5-1
Product certifications EAC
Protective treatment TH conforming to IEC 60068
IP degree of protection IP00 conforming to IEC 60529
Ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
-20…70 °C with derating
Ambient air temperature for storage -60…80 °C
Fire resistance 850 °C conforming to IEC 60068-2-1
Dielectric strength 6 kV at 50 Hz conforming to IEC 60255-5
Electromagnetic compatibility Surge withstand: 6 kV conforming to IEC 60801-5
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 16.500 cm
Package 1 Width 18.000 cm
Package 1 Length 27.500 cm
Package 1 Weight 2.909 kg
Unit Type of Package 2 S03
Number of Units in Package 2 2
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 6.311 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LRE484 | EasyPact TVS differential thermal overload relay 146…234 A – class 10A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024