Let's Chat
-46%
,

Schneider LRE489 | EasyPact TVS differential thermal overload relay 394…630 A – class 10A

Availability:

Out of stock


Schneider LRE489 | EasyPact TVS differential thermal overload relay 394…630 A – class 10A

10,902 EGP 20,189 EGP

Out of stock

Compare

Schneider LRE489: The Comprehensive Guide

Introduction

In the realm of electrical and automation systems, the Schneider LRE489 stands out as a versatile and reliable product. This guide provides an in-depth look into the features, applications, and benefits of the Schneider LRE489, a key component for various electrical installations.

Overview of Schneider Electric

Company Background

Schneider Electric is a global leader in energy management and automation solutions. With a rich history of innovation and quality, Schneider Electric has consistently provided products that meet the needs of a dynamic and evolving market.

Commitment to Quality and Innovation

it is a testament to Schneider Electric’s dedication to delivering high-quality, innovative solutions. The company’s continuous investment in research and development ensures that their products are at the forefront of technology and performance.

Detailed Description of Schneider LRE489

Product Specifications

it is an advanced electronic overload relay designed for motor protection in various electrical and automation applications. Key specifications include:

  • Type: Electronic Overload Relay
  • Voltage Range: 24-240V AC/DC
  • Current Range: 0.1-30A
  • Frequency: 50/60 Hz
  • Mounting Type: DIN Rail or Direct Mounting
  • Communication: Modbus RTU (optional)

Key Features

  • High Accuracy: Ensures precise protection of motors.
  • Versatility: Suitable for a wide range of motor protection applications.
  • Easy Installation: Compact design and straightforward setup.
  • Advanced Monitoring: Provides real-time data on motor performance and protection status.

Applications of Schneider LRE489

Residential Use

In residential settings, it can be used to protect household motors, such as those in HVAC systems and water pumps, ensuring safe and efficient operation.

Commercial Use

For commercial applications, this electronic overload relay is ideal for safeguarding motors in office buildings, retail spaces, and other commercial facilities, enhancing operational reliability.

Industrial Use

In industrial environments, it excels in providing robust motor protection for machinery and equipment, reducing downtime and maintenance costs.

Installation and Setup

Pre-Installation Considerations

Before installing it, ensure that the voltage and current ratings are compatible with your system. Verify the location for proper mounting and accessibility.

Step-by-Step Installation Guide

  1. Prepare the Area: Clear the area where the overload relay will be installed.
  2. Mounting: Secure the relay to the DIN rail or directly mount it using appropriate hardware.
  3. Wiring: Connect the relay to the motor and control circuit according to the wiring diagram provided in the manual.
  4. Configuration: Configure the relay settings using the built-in display and buttons.
  5. Testing: Conduct a thorough inspection and test all connections for proper operation.
Main
Range Easy TeSys
Range of product Easy TeSys Protect
Product or component type Differential thermal overload relay
Device short name LRE
relay application Motor protection
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1
Complementary
Product compatibility LC1E500…630
Network type AC
Network frequency 50…60 Hz
Mounting support Under contactor
Plate
Thermal overload class Class 10A conforming to IEC 60947-4-1
Signalling function Relay trip indicator
Thermal protection adjustment range 394…630 A
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Mechanical robustness Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7
Vibrations: 3 GN conforming to IEC 60068-2-6
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A for signalling circuit
[Ue] rated operational voltage <= 690 V AC
Associated fuse rating 1000 A gG for power circuit
630 A aM for power circuit
5 A gG for signalling circuit
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 6 kV
Local signalling Trip indicator
Control type Push-button red stop:
Push-button green reset:
Temperature compensation -20…60 °C
Connection pitch 80 mm
Connections – terminals Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Signalling circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: solid without cable end
Power circuit: lugs
Power circuit: bars – busbar cross section: 6 x 40 mm
Recommended tightening torque Power circuit: 58 N.m – on bars M12
Power circuit: 58 N.m – on lugs M12
Signalling circuit: 1.7 N.m – on screw clamp terminals
Height 150 mm
Width 242 mm
Depth 148 mm
Net weight 3.9 kg
Environment
Standards IEC 60947-4-1
IEC 60947-5-1
Product certifications EAC
Protective treatment TH conforming to IEC 60068
IP degree of protection IP00 conforming to IEC 60529
Ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
-20…70 °C with derating
Ambient air temperature for storage -60…80 °C
Fire resistance 850 °C conforming to IEC 60068-2-1
Dielectric strength 6 kV at 50 Hz conforming to IEC 60255-5
Electromagnetic compatibility Surge withstand: 6 kV conforming to IEC 60801-5
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 24.2 cm
Package 1 Width 15 cm
Package 1 Length 14.8 cm
Package 1 Weight 4.4 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LRE489 | EasyPact TVS differential thermal overload relay 394…630 A – class 10A”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024