Schneider LV426452 | circuit breaker ComPact NSXm N (50 kA at 415 VAC), 3P 3d, 32 A rating TMD trip unit, compression lugs and busbar connectors

Availability:

In stock


Schneider LV426452 | circuit breaker ComPact NSXm N (50 kA at 415 VAC), 3P 3d, 32 A rating TMD trip unit, compression lugs and busbar connectors

12,639 EGP 19,151 EGP

In stock

Compare

Schneider LV426452 | circuit breaker ComPact NSXm N (50 kA at 415 VAC), 3P 3d, 32 A rating TMD trip unit, compression lugs and busbar connectors

Schneider LV426452: A Comprehensive Overview of This Essential Circuit Breaker

In an era where electrical reliability is crucial, the Schneider LV426452 circuit breaker stands out as a superior choice. Designed for various applications, it offers exceptional performance and safety. Let’s delve into the specifics of this outstanding circuit breaker.

Basics of Circuit Breakers

Circuit breakers are vital components in electrical systems, designed to protect circuits from damage due to overloads or short circuits. By interrupting the electrical flow when a fault is detected, they prevent potential hazards such as fires or equipment damage.

Technical Specifications of Schneider LV426452

it is engineered to deliver high performance and reliability. Here’s a breakdown of its key specifications:

  • Electrical Ratings: It supports a voltage rating up to 690V and a current rating up to 800A.
  • Physical Dimensions: The compact design allows it to fit into various panel configurations without requiring significant modifications.

Key Features of Schneider LV426452

Performance Highlights

it is designed for optimal performance, handling high electrical loads efficiently. Its robust construction ensures it performs reliably under demanding conditions.

Safety Features

Safety is a top priority with it. It includes advanced protection features like thermal-magnetic trip units, which offer reliable protection against both overloads and short circuits.

Installation Benefits

The circuit breaker is engineered for easy installation. With clear instructions and minimal tools required, it can be installed quickly, reducing downtime and labor costs.

Applications of Schneider LV426452

Industrial Uses

In industrial settings, where electrical demands are high, it provides robust protection. It is suitable for use in manufacturing facilities, large machinery, and processing plants.

Commercial Uses

For commercial buildings, including offices and shopping centers, the LV426452 ensures electrical safety and reliability, protecting sensitive equipment and supporting smooth operations.

Residential Uses

Even in residential environments, the LV426452 offers excellent protection. It safeguards home electrical systems, ensuring safety and reliability for household appliances and wiring.

Installation Guide

Preparation and Tools Needed

Before installation, ensure the main power supply is turned off. Gather necessary tools, including screwdrivers and wire cutters.

Step-by-Step Installation Process

  1. Mounting: Install the circuit breaker in the designated panel.
  2. Wiring: Connect the input and output wires as per the manual.
  3. Securing: Ensure all connections are tight and secure.
  4. Testing: After installation, turn on the power and test the breaker to ensure it functions correctly.

Post-Installation Checks

Verify that the breaker is properly aligned and functioning as expected. Check for any signs of overheating or unusual noises.

Maintenance and Troubleshooting

Regular Maintenance Practices

To ensure longevity, perform regular inspections and maintenance:

  • Inspect for wear or damage.
  • Clean dust and debris from the breaker.
  • Test the breaker periodically.

Common Issues and Their Solutions

If the breaker trips frequently, check for overloads or short circuits. Address any underlying electrical issues promptly to prevent further problems.

SKU: LV426452 Category:
Main
Range ComPact
Product name ComPact NSXm
Range of product ComPact NSXm
Device short name NSXm 32N
Product or component type Circuit breaker
Device application Distribution
Protection
Number of poles 3P
Protected poles description 3D
[In] rated current 32 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 90 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 600…690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level N 50 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode By screws
Clip-on
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 90 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 660…690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 10000 cycles at 440 V In
20000 cycles at 440 V In/2
5000 cycles at 690 V In
10000 cycles at 690 V In/2
Mounting support Plate
DIN rail
Connection terminals compression lug/busbar
Connection pitch 35 mm with spreaders
27 mm without spreaders
9 mm pitches 9 module
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 32 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[Im] magnetic protection pick-up range 600 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX
Width (W) 81 mm
Height (H) 137 mm
Depth (D) 80 mm
Net weight 1.06 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.139 cm
Package 1 Width 12.38 cm
Package 1 Length 21.632 cm
Package 1 Weight 1.155 kg
Unit Type of Package 2 S03
Number of Units in Package 2 9
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 12.29 kg
Unit Type of Package 3 P12
Number of Units in Package 3 216
Package 3 Height 110 cm
Package 3 Width 80 cm
Package 3 Length 120 cm
Package 3 Weight 304.89 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV426452 | circuit breaker ComPact NSXm N (50 kA at 415 VAC), 3P 3d, 32 A rating TMD trip unit, compression lugs and busbar connectors”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024