Schneider LV429631 | circuit breaker ComPact NSX100F, 36 kA at 415 VAC, TMD trip unit 80 A, 3 poles 3d

Schneider Electric
Availability:

Out of stock


Schneider LV429631 | circuit breaker ComPact NSX100F, 36 kA at 415 VAC, TMD trip unit 80 A, 3 poles 3d

12,221 EGP 19,095 EGP

Out of stock

Compare

Schneider LV429631 | circuit breaker ComPact NSX100F, 36 kA at 415 VAC, TMD trip unit 80 A, 3 poles 3d

Schneider LV429631: A Comprehensive Guide to This High-Performance Circuit Breaker

In the field of electrical protection, it circuit breaker is recognized for its advanced features and reliable performance. This circuit breaker is designed to meet the needs of various applications, providing both safety and efficiency. Let’s explore what makes it a top choice in modern electrical systems.

Understanding Circuit Breakers

Circuit breakers are essential for protecting electrical circuits from damage caused by overloads or short circuits. They automatically interrupt the electrical flow when a fault is detected, helping to prevent hazards like electrical fires and equipment damage.

Technical Specifications of Schneider LV429631

The Schneider LV429631 is engineered to deliver high performance in demanding environments. Here are some of its key specifications:

  • Electrical Ratings: it supports a voltage rating of up to 690V and a current rating of up to 2500A, making it suitable for high-load applications.
  • Physical Dimensions: The circuit breaker is designed to be compact yet robust, allowing for flexible installation within various electrical panels.

Key Features of Schneider LV429631

Performance Benefits

it is built to handle significant electrical loads with ease. Its design ensures consistent and reliable performance, even in high-demand situations.

Safety Features

Safety is a top priority for it. It includes advanced protection features such as thermal-magnetic trip units that provide reliable protection against both overloads and short circuits.

Installation Advantages

One of the notable advantages of the LV429631 is its ease of installation. It comes with clear instructions and requires minimal tools, making the setup process straightforward and efficient.

Applications of Schneider LV429631

Industrial Applications

In industrial environments, the LV429631 offers robust protection for high-load applications. It is ideal for use in large-scale manufacturing facilities and heavy machinery.

Commercial Applications

For commercial buildings, such as offices and retail spaces, the LV429631 ensures a reliable and safe electrical system. It helps protect sensitive equipment and supports continuous business operations.

Residential Applications

In residential settings, the LV429631 provides excellent protection for home electrical systems. It safeguards household appliances and wiring, ensuring a safe and reliable power supply.

Installation Process

Preparation and Required Tools

Before installing the LV429631, ensure that the main power supply is turned off. Gather the necessary tools, including screwdrivers, wire cutters, and a voltage tester.

Step-by-Step Installation Guide

  1. Mounting: Install the circuit breaker in the designated panel.
  2. Wiring: Connect the input and output wires according to the manual.
  3. Securing: Tighten all connections to ensure they are secure.
  4. Testing: Once installed, turn on the power and test the breaker to verify its operation.

Post-Installation Procedures

After installation, check that the breaker is aligned correctly and functioning as expected. Look out for any signs of overheating or unusual noises.

Maintenance and Troubleshooting

Routine Maintenance Tips

To keep the LV429631 in optimal condition:

  • Perform regular inspections for wear or damage.
  • Clean the breaker to remove dust and debris.
  • Test the breaker periodically to ensure it operates correctly.

Common Problems and Solutions

Common issues with circuit breakers include frequent tripping or failure to reset. These issues can often be resolved by checking for overloads or short circuits and addressing any underlying problems.

SKU: LV429631 Category:
Main
Range ComPact
Product name ComPact NSX
Range of product ComPact NSX100…250
Device short name NSX100F
Product or component type Circuit breaker
Device application Distribution
Number of poles 3P
Protected poles description 3t
[In] rated current 80 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 508
25 kA at 480 V AC 50/60 Hz conforming to UL 508
85 kA at 240 V AC 50/60 Hz conforming to UL 508
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Performance level F 36 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 10000 cycles at 690 V In
20000 cycles at 690 V In/2
30000 cycles at 440 V In
50000 cycles at 440 V In/2
Mounting support Backplate
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 80 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 640 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.05 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.0 cm
Package 1 Width 11.5 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.773 kg
Unit Type of Package 2 S04
Number of Units in Package 2 12
Package 2 Height 30.0 cm
Package 2 Width 40.0 cm
Package 2 Length 60.0 cm
Package 2 Weight 22.042 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV429631 | circuit breaker ComPact NSX100F, 36 kA at 415 VAC, TMD trip unit 80 A, 3 poles 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024