In the realm of electrical systems, ensuring safety, efficiency, and reliability is paramount. The Schneider LV429840 Compact is a fundamental component in this endeavor. This versatile and robust circuit breaker is designed to meet the demands of various electrical applications, making it an indispensable element in modern electrical infrastructure. Let’s delve deeper into what makes this device essential for your electrical needs.

What is Schneider LV429840 Compact?

General Description

The Schneider LV429840 Compact is a molded case circuit breaker (MCCB) that belongs to Schneider Electric’s Compact NSX range. It is engineered to provide excellent protection against overloads, short circuits, and other electrical faults. Its compact design and advanced technology ensure that it can be seamlessly integrated into various electrical systems.

Key Features

  • High Performance: Offers reliable protection and operational efficiency.
  • Compact Size: Designed to save space in electrical panels.
  • Ease of Installation: User-friendly design simplifies the installation process.
  • Advanced Protection: Includes features such as adjustable trip settings and thermal-magnetic protection.

Technical Specifications

Voltage and Current Ratings

The Schneider LV429840 Compact is engineered to handle a broad range of voltages and currents. It typically operates at a voltage rating of 690V and offers current ratings up to 250A, making it suitable for both low and medium voltage applications.

Dimensions and Weight

One of its notable features is its compact size. The Schneider LV429840 Compact measures approximately 130mm in height, 105mm in width, and 60mm in depth, with a weight of around 1.5 kg. This compact form factor allows for easy integration into tight spaces without compromising performance.

Environmental Ratings

This circuit breaker is designed to operate in various environmental conditions. It boasts an IP40 rating, making it resistant to dust and other solid particles. Additionally, it can operate in temperatures ranging from -25°C to +70°C, ensuring reliability in diverse conditions.

Benefits of Using Schneider LV429840 Compact

Safety Enhancements

Safety is of utmost importance with the Schneider LV429840 Compact. Its advanced protection features help prevent electrical accidents, thereby safeguarding both equipment and personnel.

Efficiency and Reliability

This circuit breaker is built for efficiency, minimizing downtime and ensuring continuous operation. Its reliability is backed by rigorous testing and quality control measures.

Cost-Effectiveness

Investing in the Schneider LV429840 Compact can lead to significant cost savings over time. Its durability and low maintenance requirements reduce operational costs, making it a cost-effective choice for various applications.

Applications of Schneider LV429840 Compact

Industrial Use

In industrial settings, the Schneider LV429840 Compact is employed to protect machinery and equipment from electrical faults. Its robust design ensures it can withstand harsh industrial environments.

Commercial Buildings

For commercial buildings, this circuit breaker provides reliable protection for electrical systems, ensuring the safety and efficiency of office spaces, retail stores, and other commercial facilities.

Residential Settings

While more commonly used in industrial and commercial environments, the Schneider LV429840 Compact can also be utilized in residential settings where high-capacity electrical protection is required.

Installation Process

Pre-Installation Checklist

Before installing the Schneider LV429840 Compact, ensure that you have all necessary tools and have reviewed the installation manual. Verify that the circuit breaker is compatible with your electrical system.

Step-by-Step Guide

  1. Turn Off Power: Ensure all power sources are disconnected to prevent electrical shock.
  2. Mount the Breaker: Securely mount the circuit breaker in the designated panel.
  3. Connect Wires: Attach the incoming and outgoing wires to the appropriate terminals.
  4. Test Connections: Double-check all connections to ensure they are secure.
  5. Power On: Restore power and test the circuit breaker to confirm it is functioning correctly.

Maintenance and Troubleshooting

Regular Maintenance Tips

To ensure optimal performance, regularly inspect the Schneider LV429840 Compact for signs of wear or damage. Clean the breaker and surrounding area to prevent dust accumulation.

Common Issues and Solutions

  • Tripping: If the breaker trips frequently, check for overload conditions or short circuits.
  • Overheating: Ensure proper ventilation around the breaker to prevent overheating.
  • Loose Connections: Regularly check and tighten any loose connections to maintain reliable performance.

Comparison with Other Models

Schneider LV429840 vs. Competitors

Compared to other models, the Schneider LV429840 Compact offers superior performance, ease of installation, and advanced safety features. Its compact size and robust design set it apart from competitors.

Pros and Cons

Pros:

  • High reliability and safety
  • Compact and space-saving design
  • Easy installation and maintenance

Cons:

  • Higher initial cost compared to some alternatives
  • May offer more features than necessary for small-scale applications
SKU: LV429840 Category:
Main
RangeComPact
Product nameComPact NSX
range of productComPact NSX100…250
Device short nameNSX100N
Product or component typeeCircuit breaker
Device applicationDistribution
Number of poles3P
Protected poles description3t
[In] rated current100 A at 40 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
utilisation categoryCategory A
[Icu] rated ultimate short-circuit breaking capacity85 kA at 240 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
50 kA at 480 V AC 50/60 Hz conforming to UL 508
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Performance levelN 50 kA 415 V AC
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit protection functionsLI
control typeToggle
Circuit breaker mounting modeFixed
Complementary
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ics] rated service short-circuit breaking capacity10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability50000 cycles
Electrical durability10000 cycles at 690 V In
20000 cycles at 690 V In/2
30000 cycles at 440 V In
50000 cycles at 440 V In/2
mounting supportBackplate
Upside connectionFront
downside connectionFront
Connection pitch35 mm
Protection typeL : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)Adjustable
[Ir] long-time protection pick-up adjustment range0.7…1 x In
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range120…400 s at 1.5 x In
15 s at 6 x Ir
Short-time protection pick-up adjustment type IsdFixed
[Isd] Short-time protection pick-up adjustment range800 A
Short-time protection delay adjustment type tsdFixed
earth-leakage protectionWithout
Number of slots for electrical auxiliaries5 slot(s)
Width (W)105 mm
Height (H)161 mm
Depth (D)86 mm
Net weight2.05 kg
Environment
StandardsEN/IEC 60947
product certificationsCCC
EAC
Marine
Overvoltage categoryClass II
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Relative humidity0…95 %
Operating altitude0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.7 cm
Package 1 Width11.6 cm
Package 1 Length19.2 cm
Package 1 Weight1.783 kg
Unit Type of Package 2S04
Number of Units in Package 212
Package 2 Height30.0 cm
Package 2 Width40.0 cm
Package 2 Length60.0 cm
Package 2 Weight22.162 kg
Contractual warranty
Warranty18 months

Main Document

Data Sheet : LV429840 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV429840 Compact | circuit breaker ComPact NSX100N, 50 kA at 415 VAC, TMD trip unit 100 A, 3 poles 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat