-36%
, , ,

Schneider LV429842 | circuit breaker ComPact NSX100N, 50 kA at 415 VAC, TMD trip unit 63 A, 3 poles 3d

Schneider Electric
Availability:

Out of stock


Schneider LV429842 | circuit breaker ComPact NSX100N, 50 kA at 415 VAC, TMD trip unit 63 A, 3 poles 3d

13,945.02 EGP 21,789.09 EGP

Out of stock

Schneider LV429842 | circuit breaker ComPact NSX100N, 50 kA at 415 VAC, TMD trip unit 63 A, 3 poles 3d

 

Technical Specifications:

  • Type: Circuit Breaker

  • Model: Schneider LV429842 | ComPact NSX100N

  • Nominal Current: 63 Amps

  • Maximum Breaking Capacity: 50 kA at 415 VAC

  • Number of Poles: 3 Poles

  • Trip Unit: TMD (Thermal Magnetic Release)

  • Short-Circuit Protection: Designed to protect against short circuits, reducing the risk of damage and system failures.

Features:

  1. Reliable Protection:
    The circuit breaker provides comprehensive protection against overloads and short circuits, minimizing the risk of electrical faults and damage to equipment.

  2. Flexibility:
    The TMD trip unit is adjustable, allowing it to be tailored to meet specific operational requirements, offering ease of adaptation to real-world electrical conditions.

  3. Advanced Technology:
    Incorporates advanced technology to enhance performance and reduce sudden current spikes, helping to prevent electrical faults.

  4. High Short-Circuit Withstand Capacity:
    With a maximum breaking capacity of 50 kA, the circuit breaker is ideal for industrial and commercial applications that require high protection against short circuit currents.

  5. Ease of Maintenance and Installation:
    The breaker is designed for easy installation and maintenance, reducing operational costs and improving electrical system efficiency.

Applications:

  • Industrial Applications:
    Used for protecting heavy electrical equipment such as motors and large industrial systems, where high protection against overloads and short circuits is essential.

  • Electrical Distribution Systems:
    Installed in distribution boards within commercial and industrial buildings to provide continuous protection for all connected electrical systems.

  • Motor Control Systems:
    Provides protection for motor groups in industries requiring high electrical currents, ensuring safe operation of machinery and equipment.

  • Solar Power Systems:
    Can be used to protect electrical circuits in solar power installations from unwanted electrical faults.

  • High-Rise Buildings and Large Residential Complexes:
    Protects electrical networks in high-rise buildings and large residential complexes, ensuring safety for all users by preventing electrical failures.

Main
Range ComPact
Product name ComPact NSX
Range of product ComPact NSX100…250
Device short name NSX100N
Product or component type Circuit breaker
Device application Distribution
Number of poles 3P
Protected poles description 3t
[In] rated current 63 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 85 kA at 240 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
20 kA at 600 V AC 50/60 Hz conforming to UL 508
50 kA at 480 V AC 50/60 Hz conforming to UL 508
36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Performance level N 50 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 10000 cycles at 690 V In
20000 cycles at 690 V In/2
30000 cycles at 440 V In
50000 cycles at 440 V In/2
Mounting support Backplate
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 63 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 500 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.05 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.4 cm
Package 1 Width 11.6 cm
Package 1 Length 19.2 cm
Package 1 Weight 1.779 kg
Unit Type of Package 2 S04
Number of Units in Package 2 12
Package 2 Height 30.0 cm
Package 2 Width 40.0 cm
Package 2 Length 60.0 cm
Package 2 Weight 22.114 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV429842 | circuit breaker ComPact NSX100N, 50 kA at 415 VAC, TMD trip unit 63 A, 3 poles 3d”

There are no reviews yet.

SHOPPING CART

close
Let's Chat