Schneider LV430671 | circuit breaker ComPact NSX160H, 70 kA at 415 VAC, TMD trip unit 125 A, 3 poles 3d

Schneider Electric
Availability:

In stock


Schneider LV430671 | circuit breaker ComPact NSX160H, 70 kA at 415 VAC, TMD trip unit 125 A, 3 poles 3d

20,173 EGP 31,521 EGP

In stock

Compare

Schneider LV430671 | circuit breaker ComPact NSX160H, 70 kA at 415 VAC, TMD trip unit 125 A, 3 poles 3d

Introduction

it circuit breaker is a vital component in modern electrical systems, designed to protect circuits from damage caused by overloads and short circuits. Its importance spans across various applications, ensuring the safety and efficiency of electrical operations in industrial, commercial, and residential settings.

What is Schneider LV430671?

it is a high-performance molded case circuit breaker (MCCB) from Schneider Electric’s Compact NSX range. Renowned for its durability and reliability, this circuit breaker is engineered to handle substantial electrical loads while providing excellent protection.

Technical Specifications

Understanding the technical specifications of it is essential for its proper application:

  • Voltage Rating: The LV430671 is rated for a voltage of up to 690V AC, making it versatile for various electrical systems.
  • Current Rating: It has a current rating of 250A, allowing it to manage significant electrical currents efficiently.
  • Breaking Capacity: With a high breaking capacity, it can effectively interrupt high fault currents, ensuring system protection.

Applications of Schneider LV430671

Industrial Applications

In industrial environments, it is indispensable for protecting heavy machinery and complex electrical systems. Its high current and voltage ratings make it ideal for use in factories and manufacturing plants.

Commercial Applications

it is equally valuable in commercial settings, such as office buildings and shopping centers. It ensures the smooth operation of electrical systems and minimizes the risk of disruptions caused by electrical faults.

Residential Applications

While more commonly used in larger installations, the Schneider LV430671 can also be employed in residential properties with higher electrical demands. It provides a robust solution for protecting home electrical systems.

Benefits of Using Schneider LV430671

Reliability

it is designed to perform consistently under various conditions, providing reliable protection against electrical faults.

Safety

Safety is a critical aspect of any electrical system. The LV430671’s high breaking capacity and robust construction ensure that it can handle electrical faults without causing damage or hazards.

Efficiency

By maintaining reliable protection and reducing the risk of electrical failures, the Schneider LV430671 contributes to the overall efficiency of electrical systems, helping to reduce energy consumption and operational costs.

Installation Process

Pre-installation Requirements

Before installing the Schneider LV430671, gather all necessary tools and ensure the electrical system is properly configured for integration.

Step-by-Step Installation Guide

  1. Turn Off Power: Ensure the main power supply is turned off to prevent electric shock.
  2. Mounting: Secure the circuit breaker in its designated position within the electrical panel.
  3. Wiring: Connect the incoming and outgoing wires to the appropriate terminals on the circuit breaker.
  4. Testing: Test the circuit breaker post-installation to ensure it is functioning correctly.

Safety Precautions

Always adhere to safety guidelines when working with electrical systems. Use appropriate protective gear and verify all connections before restoring power.

Maintenance Tips

Routine Checks

Regularly inspect the Schneider LV430671 for signs of wear or damage. Routine checks can help identify potential issues before they escalate.

Troubleshooting Common Issues

If the circuit breaker trips frequently or shows signs of malfunction, refer to the user manual for troubleshooting tips or consult a professional electrician.

SKU: LV430671 Category:
Main
Range ComPact
Product name ComPact NSX
Range of product ComPact NSX100…250
Device short name NSXm 160H
Product or component type Circuit breaker
Device application Distribution
Number of poles 3P
Protected poles description 3t
[In] rated current 125 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 508
85 kA at 240 V AC 50/60 Hz conforming to UL 508
65 kA at 480 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Performance level H 70 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 40000 cycles
Electrical durability 7500 cycles at 690 V In
15000 cycles at 690 V In/2
20000 cycles at 440 V In
40000 cycles at 440 V In/2
Mounting support Backplate
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Trip unit rating 125 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7…1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Short-time protection pick-up adjustment type Isd Fixed
[Isd] Short-time protection pick-up adjustment range 1250 A
Short-time protection delay adjustment type tsd Fixed
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 2.2 kg
Environment
Standards EN/IEC 60947
Product certifications CCC
EAC
Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0…2000 m without derating
2000 m…5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.0 cm
Package 1 Width 11.0 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.829 kg
Unit Type of Package 2 S04
Number of Units in Package 2 12
Package 2 Height 30.0 cm
Package 2 Width 40.0 cm
Package 2 Length 60.0 cm
Package 2 Weight 22.714 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV430671 | circuit breaker ComPact NSX160H, 70 kA at 415 VAC, TMD trip unit 125 A, 3 poles 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024