Schneider LV510303 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 40 A rating thermal magnetic TM-D trip unit, 3P 3d

Schneider Electric
Availability:

Out of stock


Schneider LV510303 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 40 A rating thermal magnetic TM-D trip unit, 3P 3d

6,562 EGP 11,028 EGP

Out of stock

Compare

Schneider LV510303 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 40 A rating thermal magnetic TM-D trip unit, 3P 3d

Schneider LV510303 Description

The Schneider LV510303 is a low-voltage electrical component designed for use in a variety of electrical distribution systems. Schneider Electric, a global leader in energy management and automation, manufactures this part to meet the demands of modern electrical installations, ensuring safety, reliability, and performance.

Key Features

  • High-Quality Construction: The LV510303 is built with durable materials, ensuring long-lasting performance even in demanding environments.
  • Compact Design: Its compact size makes it easy to integrate into existing electrical panels or distribution boards without requiring significant space.
  • Versatile Application: This component is suitable for a wide range of low-voltage applications, making it a flexible choice for both commercial and industrial systems.

Technical Specifications

  • Voltage Rating: The LV510303 is engineered to operate within a specific voltage range, providing safe and efficient power distribution in low-voltage systems.
  • Current Capacity: It supports a particular current range, making it suitable for various electrical loads and applications.
  • Durability: Designed to withstand harsh conditions, the LV510303 offers reliable performance over an extended period.

Applications

  • Commercial Buildings: Ideal for use in office buildings, shopping centers, and other commercial facilities where reliable power distribution is critical.
  • Industrial Settings: The LV510303 is suitable for managing power distribution in industrial plants, ensuring stable operation of machinery and equipment.
  • Residential Complexes: This component can be used in residential electrical systems to ensure safe and reliable power distribution.

Installation Guidelines

  • Mounting: The LV510303 is designed for straightforward installation in standard electrical panels, with clear guidelines provided by Schneider Electric.
  • Connection: Ensure proper electrical connections during installation to maximize efficiency and safety.
  • Safety Considerations: Always follow Schneider Electric’s recommended safety practices during installation to prevent accidents and ensure compliance with electrical standards.

Maintenance

  • Routine Inspections: Regular maintenance of the LV510303 involves periodic checks for wear and tear, secure connections, and proper functionality.
  • Cleaning: Keeping the component free from dust and debris will help maintain optimal performance and prolong its lifespan.

Conclusion

The Schneider LV510303 is a reliable and versatile component designed for low-voltage electrical systems. Its robust construction, compact design, and ease of installation make it an excellent choice for a variety of applications, from commercial to industrial settings.

brands

Main
RangeEasyPact
Range of productEasyPact CVS100…250
Product nameEasyPact CVS
Device short nameCVS100B
Product or component typeCircuit breaker
Device applicationDistribution
poles description3P
Protected poles description3D
Earth leakage protection (Vigi add on)Without
[In] rated current40 A at 40 °C
network typeAC
Utilisation categoryCategory A
[Icu] Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating40 A at 40 °C
Protection typeShort-circuit protection (magnetic)
Overload protection (thermal)
Complementary
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
network frequency50/60 Hz
Breaking capacity codeB
[Ics] rated service breaking capacity15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability30000 cycles
Electrical durability12000 cycles 415 V In conforming to IEC 60947-2
Control typeToggle
Thermal protection adjustment range28…40 A
Long time pick-up adjustment type IrAdjustable
Long time pick-up adjustment range0.7…1 x In
Long time delay adjustment typeFixed
Instantaneous pick-up adjustment type IiFixed
instantaneous pick-up adjustment range500 A
Contact position indicatorYes
mounting supportBackplate
mounting modeFixed
Upside connectionFront
downside connectionFront
Connections – terminalsScrew connection
Connection pitch35 mm
Compatibility codeCVS100
Width105 mm
Depth86 mm
Height161 mm
Net weight1.5 kg
Environment
StandardsIEC 60947-2
EN 60947-2
Product certificationsIEC
GOST
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.800 cm
Package 1 Width13.600 cm
Package 1 Length19.200 cm
Package 1 Weight1.654 kg
Unit Type of Package 2S04
Number of Units in Package 212
Package 2 Height30.000 cm
Package 2 Width40.000 cm
Package 2 Length60.000 cm
Package 2 Weight20.614 kg

Main Document