-41%
, , ,

Schneider LV510336 | circuit breaker EasyPact CVS100F, 36 kA at 415 VAC, 80 A rating thermal magnetic TM-D trip unit, 3P 3d


Schneider LV510336 | circuit breaker EasyPact CVS100F, 36 kA at 415 VAC, 80 A rating thermal magnetic TM-D trip unit, 3P 3d

7,685 EGP 12,916 EGP

Compare

Schneider LV510336 | circuit breaker EasyPact CVS100F, 36 kA at 415 VAC, 80 A rating thermal magnetic TM-D trip unit, 3P 3d

Technical Specifications

  • Model: Schneider LV510336 | EasyPact CVS100F
  • Rated Current: 80A
  • Breaking Capacity: 36 kA at 415V AC
  • Poles: 3P (Three-Pole)
  • Trip Unit Type: Thermal-Magnetic TM-D
  • Voltage Rating: 415V AC
  • Mounting Type: Fixed
  • Protection Type: Overload & Short Circuit
  • Standard Compliance: IEC 60947-2
  • Operating Temperature: -25°C to 70°C

Key Features

  1. Superior Circuit Protection
    • Thermal-Magnetic TM-D Trip Unit provides dual protection:
      Thermal protection for long-duration overloads.
      Magnetic protection for instantaneous short-circuit faults.
    • 36 kA breaking capacity at 415V AC ensures safety in high-demand environments.
  2. Durable & Reliable Performance
    • Designed for long-term operation in industrial and commercial settings.
    • Reduces the risk of electrical failures and equipment damage.
  3. Easy Installation & Operation
    • Three-pole (3P) configuration for efficient three-phase power distribution.
    • Compact and lightweight design for seamless integration into electrical panels.
  4. Compliance with International Standards
    • Meets IEC 60947-2 certification requirements for quality and safety.
    • Ensures safe operation in diverse electrical environments.

Applications

The Schneider LV510336 | EasyPact CVS100F is widely used in various sectors, including:

Industrial Facilities – Protecting machinery, motors, and electrical systems.
Commercial Buildings – Ensuring safe power distribution in offices and retail spaces.
Residential Installations – Providing high-level circuit protection in homes.
Power Distribution Systems – Used in electrical switchgear and distribution panels.

Main
RangeEasyPact
Range of productEasyPact CVS100…250
product nameEasyPact CVS
Device short nameCVS100F
Product or component typeCircuit breaker
Device applicationDistribution
Poles description3P
Protected poles description3D
Earth leakage protection (Vigi add on)Without
[In] rated current80 A at 40 °C
network typeAC
Utilisation categoryCategory A
[Icu] Breaking capacity36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating80 A at 40 °C
Protection typeShort-circuit protection (magnetic)
Overload protection (thermal)
Complementary
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Breaking capacity codeF
[Ics] rated service breaking capacity18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability30000 cycles
Electrical durability12000 cycles 415 V In conforming to IEC 60947-2
Control typeToggle
Thermal protection adjustment range56…80 A
Long time pick-up adjustment type IrAdjustable
Long time pick-up adjustment range0.7…1 x In
Long time delay adjustment typeFixed
Instantaneous pick-up adjustment type IiFixed
Instantaneous pick-up adjustment range640 A
Contact position indicatorYes
Mounting supportBackplate
Mounting modeFixed
Upside connectionFront
Downside connectionFront
Connections – terminalsScrew connection
Connection pitch35 mm
Compatibility codeCVS100
Width105 mm
Depth86 mm
Height161 mm
Product weight1.5 kg
Environment
StandardsEN 60947-2
IEC 60947-2
Product certificationsGOST
IEC
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.000 cm
Package 1 Width14.000 cm
Package 1 Length19.000 cm
Package 1 Weight1.680 kg
Unit Type of Package 2S03
Number of Units in Package 26
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight10.500 kg
Unit Type of Package 3P12
Number of Units in Package 348
Package 3 Height45.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight96.000 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV510336 | circuit breaker EasyPact CVS100F, 36 kA at 415 VAC, 80 A rating thermal magnetic TM-D trip unit, 3P 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat