The Schneider LV510337

it is a key component in modern electrical systems, providing essential control and protection against electrical faults. Its importance in ensuring the safety and efficiency of electrical installations makes it a critical choice for a variety of applications, from industrial environments to residential settings.

What is Schneider LV510337?

it is a high-performance circuit breaker from Schneider Electric’s extensive range of electrical protection devices. This circuit breaker is designed to manage significant electrical loads and provide reliable protection against overloads and short circuits.

Technical Specifications

To make the most of it, it’s important to understand its technical specifications:

  • Voltage Rating: The LV510337 is rated for voltages up to 690V AC, making it suitable for a wide range of electrical systems.
  • Current Rating: It supports a current rating of up to 125A, allowing it to handle substantial electrical currents effectively.
  • Breaking Capacity: This circuit breaker features a high breaking capacity, ensuring it can safely interrupt fault currents and protect the system from potential damage.

Applications of Schneider LV510337

Industrial Applications

In industrial settings, it is essential for controlling and protecting machinery and complex electrical systems. Its robust current and voltage ratings make it ideal for factories and manufacturing plants where electrical loads are significant.

Commercial Applications

it is equally valuable in commercial environments, such as office buildings and retail spaces. It ensures the smooth operation of electrical systems, preventing disruptions caused by electrical faults.

Residential Applications

it can also be used in residential properties with higher electrical demands. It provides reliable protection for home electrical systems, ensuring safety and efficiency.

Benefits of Using Schneider LV510337

Reliability

it is engineered to deliver consistent performance under various conditions, offering reliable protection for electrical systems.

Safety

Safety is a crucial aspect of any electrical system. The LV510337’s robust construction ensures it can handle electrical faults without causing damage or hazards.

Efficiency

By maintaining reliable protection and reducing the risk of electrical failures, the Schneider LV510337 contributes to the overall efficiency of electrical systems, helping to reduce energy consumption and operational costs.

Installation Process

Pre-installation Requirements

Before installing it, gather all necessary tools and ensure the electrical system is properly configured for integration.

Step-by-Step Installation Guide

  1. Turn Off Power: Ensure the main power supply is completely turned off to avoid electric shock.
  2. Mounting: Secure the circuit breaker in its designated position within the electrical panel.
  3. Wiring: Connect the incoming and outgoing wires to the appropriate terminals on the circuit breaker.
  4. Testing: Conduct tests to ensure the circuit breaker is functioning correctly after installation.

Safety Precautions

Always follow safety guidelines when working with electrical systems. Use appropriate protective gear and verify all connections before restoring power.

Maintenance Tips

Routine Checks

Regularly inspect it for signs of wear or damage. Routine checks can help identify potential issues before they escalate.

Troubleshooting Common Issues

If the circuit breaker fails to operate or shows signs of malfunction, refer to the user manual for troubleshooting tips or consult a professional electrician.

SKU: LV510337 Category:
Main
Range EasyPact
Range of product EasyPact CVS100…250
Product name EasyPact CVS
Device short name CVS100F
Product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
Earth leakage protection (Vigi add on) Without
[In] rated current 100 A at 40 °C
Network type AC
Utilisation category Category A
[Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 100 A at 40 °C
Protection type Short-circuit protection (magnetic)
Overload protection (thermal)
Complementary
[Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
Network frequency 50/60 Hz
Breaking capacity code F
[Ics] rated service breaking capacity 18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 30000 cycles
Electrical durability 12000 cycles 415 V In conforming to IEC 60947-2
Control type Toggle
Thermal protection adjustment range 70…100 A
Long time pick-up adjustment type Ir Adjustable
Long time pick-up adjustment range 0.7…1 x In
Long time delay adjustment type Fixed
Instantaneous pick-up adjustment type Ii Fixed
instantaneous pick-up adjustment range 800 A
Contact position indicator Yes
Mounting support Backplate
Mounting mode Fixed
Upside connection Front
downside connection Front
Connections – terminals Screw connection
Connection pitch 35 mm
Compatibility code CVS100
Width 105 mm
Depth 86 mm
Height 161 mm
Net weight 1.5 kg
Environment
Standards IEC 60947-2
EN 60947-2
Product certifications IEC
GOST
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.000 cm
Package 1 Width 14.000 cm
Package 1 Length 19.000 cm
Package 1 Weight 1.671 kg
Unit Type of Package 2 S03
Number of Units in Package 2 6
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 10.446 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV510337 | circuit breaker EasyPact CVS100F, 36 kA at 415 VAC, 100 A rating thermal magnetic TM-D trip unit, 3P 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024