-40%
, , ,

Schneider LV516302 | circuit breaker EasyPact CVS160B, 25 kA at 415 VAC, 125 A rating thermal magnetic TM-D trip unit, 3P 3d

Schneider Electric
Availability:

In stock


Schneider LV516302 | circuit breaker EasyPact CVS160B, 25 kA at 415 VAC, 125 A rating thermal magnetic TM-D trip unit, 3P 3d

8,132.82 EGP 13,668.60 EGP

In stock

Schneider LV516302 | circuit breaker EasyPact CVS160B, 25 kA at 415 VAC, 125 A rating thermal magnetic TM-D trip unit, 3P 3d

Technical Specifications

  • Brand: Schneider Electric
  • Model: EasyPact CVS160B
  • Product Number: LV516302
  • Type: Thermal-Magnetic (TM-D) Circuit Breaker
  • Poles: 3 Poles (3P)
  • Short-Circuit Breaking Capacity: 25 kA at 415V AC
  • Rated Voltage: 415V AC
  • Rated Current: 125 Amps (A)
  • Category: Low Voltage Circuit Breaker
  • Mounting Type: Panel Mount

Key Features

  1. Reliable Protection:
    • Provides efficient protection against overloads and short circuits using a thermal-magnetic trip unit.
  2. High Short-Circuit Capacity:
    • Handles up to 25 kA at 415V AC, making it suitable for industrial and commercial environments.
  3. Durable Construction:
    • Made from high-quality materials to withstand harsh environmental and operational conditions.
  4. Easy Installation & Maintenance:
    • Designed for quick and easy integration into electrical panels without complex tools.
  5. High Efficiency & Safety:
    • Enhances electrical system reliability and reduces risks from excessive electrical loads.
  6. Compliance with International Standards:
    • Meets IEC 60947-2 standards, ensuring safe and reliable performance.

Applications

This circuit breaker is widely used in various applications, including:
Residential Buildings: Protects home electrical systems from overloads and short circuits.
Commercial Buildings: Ideal for offices, malls, and business centers to ensure electrical safety.
Industrial Facilities: Provides reliable protection for machines and heavy equipment.
Renewable Energy Systems: Suitable for solar power systems to ensure electrical stability.

brands

Main
Range EasyPact
Range of product EasyPact CVS100…250
Product name EasyPact CVS
Device short name CVS160B
Product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
Earth leakage protection (Vigi add on) Without
[In] rated current 125 A at 40 °C
network type AC
Utilisation category Category A
[Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 125 A at 40 °C
Protection type Short-circuit protection (magnetic)
Overload protection (thermal)
Complementary
[Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
network frequency 50/60 Hz
Breaking capacity code B
[Ics] rated service breaking capacity 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 25000 cycles
Electrical durability 12000 cycles 415 V In conforming to IEC 60947-2
Control type Toggle
Thermal protection adjustment range 87.5…125 A
Long time pick-up adjustment type Ir Adjustable
Long time pick-up adjustment range 0.7…1 x In
Long time delay adjustment type Fixed
Instantaneous pick-up adjustment type Ii Fixed
instantaneous pick-up adjustment range 1250 A
Contact position indicator Yes
mounting support Backplate
mounting mode Fixed
Upside connection Front
downside connection Front
Connections – terminals Screw connection
Connection pitch 35 mm
Compatibility code CVS160
Width 105 mm
Depth 86 mm
Height 161 mm
Net weight 1.5 kg
Environment
Standards EN 60947-2
IEC 60947-2
Product certifications IEC
GOST
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 13.500 cm
Package 1 Width 11.300 cm
Package 1 Length 19.200 cm
Package 1 Weight 1.755 kg
Unit Type of Package 2 S04
Number of Units in Package 2 12
Package 2 Height 30.000 cm
Package 2 Width 40.000 cm
Package 2 Length 60.000 cm
Package 2 Weight 21.622 kg
Main
Range EasyPact
Range of product EasyPact CVS100...250
Product name EasyPact CVS
Device short name CVS160B
Product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
Earth leakage protection (Vigi add on) Without
[In] rated current 125 A at 40 °C
network type AC
Utilisation category Category A
[Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 125 A at 40 °C
Protection type Short-circuit protection (magnetic) Overload protection (thermal)
Complementary
[Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
network frequency 50/60 Hz
Breaking capacity code B
[Ics] rated service breaking capacity 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 25000 cycles
Electrical durability 12000 cycles 415 V In conforming to IEC 60947-2
Control type Toggle
Thermal protection adjustment range 87.5…125 A
Long time pick-up adjustment type Ir Adjustable
Long time pick-up adjustment range 0.7...1 x In
Long time delay adjustment type Fixed
Instantaneous pick-up adjustment type Ii Fixed
instantaneous pick-up adjustment range 1250 A
Contact position indicator Yes
mounting support Backplate
mounting mode Fixed
Upside connection Front
downside connection Front
Connections - terminals Screw connection
Connection pitch 35 mm
Compatibility code CVS160
Width 105 mm
Depth 86 mm
Height 161 mm
Net weight 1.5 kg
Environment
Standards EN 60947-2 IEC 60947-2
Product certifications IEC GOST
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 13.500 cm
Package 1 Width 11.300 cm
Package 1 Length 19.200 cm
Package 1 Weight 1.755 kg
Unit Type of Package 2 S04
Number of Units in Package 2 12
Package 2 Height 30.000 cm
Package 2 Width 40.000 cm
Package 2 Length 60.000 cm
Package 2 Weight 21.622 kg

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV516302 | circuit breaker EasyPact CVS160B, 25 kA at 415 VAC, 125 A rating thermal magnetic TM-D trip unit, 3P 3d”

There are no reviews yet.

SHOPPING CART

close

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024