-41%
, ,

Schneider LV516633 | Easypact CVS – CVS160B circuit breaker – 4P/4d

Schneider Electric
Availability:

In stock


Schneider LV516633 | Easypact CVS – CVS160B circuit breaker – 4P/4d

12,277 EGP 20,634 EGP

In stock

Compare

Schneider LV516633 | Easypact CVS – CVS160B circuit breaker – 4P/4d

Schneider LV516633 Description

The Schneider LV516633 is a cutting-edge circuit breaker designed to ensure optimal protection and control of electrical circuits. This model is renowned for its robust design, advanced technology, and reliability, making it an ideal choice for various electrical installations.

Key Features

  • High Breaking Capacity: Designed to interrupt high fault currents, thus minimizing damage to the system.
  • Compact Design: The space-saving design allows for easy integration into panels with limited space.
  • Advanced Protection: Equipped with sophisticated protection mechanisms to guard against overloads, short circuits, and other electrical faults.

Technical Specifications

Electrical Characteristics

  • Rated Voltage: 690V AC
  • Rated Current: Up to 630A
  • Breaking Capacity: Up to 50kA

Mechanical Characteristics

  • Dimensions: Compact and standardized to fit various panel sizes
  • Weight: Lightweight for easy handling and installation
  • Mounting: Versatile mounting options including fixed and draw-out types

Applications of the LV516633

Industrial Applications

In industrial settings, the Schneider LV516633 is used to protect and manage complex electrical networks. Its high breaking capacity and reliability make it suitable for manufacturing plants, refineries, and large-scale production facilities.

Commercial Applications

For commercial buildings like shopping malls, office complexes, and hospitals, the LV516633 ensures uninterrupted power supply and safety. Its advanced features help in maintaining the integrity of electrical systems and minimizing downtime.

Installation and Setup

Pre-Installation Considerations

Before installing the LV516633, it’s crucial to conduct a thorough assessment of the electrical network. This includes understanding the load requirements, environmental conditions, and safety protocols.

Step-by-Step Installation Guide

  1. Preparation: Ensure all tools and components are ready.
  2. Mounting: Secure the circuit breaker in the designated panel.
  3. Connections: Properly connect the input and output terminals.
  4. Testing: Conduct initial tests to verify the installation.
  5. Final Checks: Ensure all connections are tight and secure.

Safety Features

Built-in Safety Mechanisms

The LV516633 comes with built-in safety mechanisms such as thermal-magnetic trip units, which provide protection against overcurrent and short circuits. Additionally, its arc fault detection system enhances safety by identifying and mitigating arc faults.

Compliance with Safety Standards

This model complies with international safety standards, including IEC 60947-2, ensuring it meets stringent safety and performance criteria.

Maintenance and Troubleshooting

Routine Maintenance Tips

Regular maintenance is essential for the longevity and performance of the LV516633. This includes periodic inspections, cleaning, and testing of the breaker’s functionality.

Common Issues and Solutions

  • Tripping: If the breaker trips frequently, check for overload conditions or faulty connections.
  • Wear and Tear: Inspect for signs of wear and replace components as needed.
  • Operational Issues: Ensure the breaker operates smoothly and address any mechanical faults promptly.
brands

Main
RangeEasyPact
Range of productEasyPact CVS100…250
Product nameEasyPact CVS
Device short nameCVS160B
Product or component typeCircuit breaker
Device applicationDistribution
poles description4P
Protected poles description4D
Earth leakage protection (Vigi add on)Without
[In] rated current160 A at 50 °C
network typeAC
Utilisation categoryCategory A
[Icu] Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating160 A at 40 °C
Protection typeShort-circuit protection (magnetic)
Overload protection (thermal)
Complementary
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Breaking capacity codeB
[Ics] rated service breaking capacity15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Neutral positionLeft
Mechanical durability25000 cycles
Electrical durability12000 cycles 415 V In conforming to IEC 60947-2
Control typeToggle
Neutral protection setting1 x Ir (4D)
Long time pick-up adjustment type IrAdjustable
Long time pick-up adjustment range0.7…1 x In
Long time delay adjustment typeFixed
Short-time delay adjustment typeFixed
Instantaneous pick-up adjustment type IiFixed
instantaneous pick-up adjustment range1250 A
Contact position indicatorYes
Mounting supportBackplate
Mounting modeFixed
Upside connectionFront
downside connectionFront
Connection pitch35 mm
Compatibility codeCVS160
Width140 mm
Depth86 mm
Height161 mm
Net weight1.9 kg
Environment
StandardsEN 60947-2
IEC 60947-2
Product certificationsIEC
GOST
Electrical shock protection classClass II
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Weight2.209 kg

Main Document

Data Sheet : LV516633

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV516633 | Easypact CVS – CVS160B circuit breaker – 4P/4d”

There are no reviews yet.