Schneider LV540306 Description
Main
RangeEasyPact
Range of productEasyPact CVS400…630
Product nameEasyPact CVS
Device short nameCVS400F
Product or component typeCircuit breaker
Device applicationDistribution
poles description3P
Protected poles description3D
Earth leakage protection (Vigi add on)Without
[In] rated current400 A at 40 °C
network typeAC
Utilisation categoryCategory A
[Icu] Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Trip unit rating400 A at 40 °C
Protection typeShort-circuit protection (magnetic)
Overload protection (thermal)
Complementary
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
network frequency50/60 Hz
Breaking capacity codeF
[Ics] rated service breaking capacity40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
23 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability15000 cycles
Electrical durability6000 cycles 415 V In conforming to IEC 60947-2
Control typeToggle
Thermal protection adjustment range280…400 A
Long time pick-up adjustment type IrAdjustable
Long time pick-up adjustment range0.7…1 x In
Long time delay adjustment typeFixed
Instantaneous pick-up adjustment type IiAdjustable
instantaneous pick-up adjustment range5…10 x In
Contact position indicatorYes
mounting supportBackplate
mounting modeFixed
Upside connectionFront
downside connectionFront
Connections – terminalsScrew connection
Connection pitch45 mm
Compatibility codeCVS400
Width140 mm
Depth110 mm
Height255 mm
Net weight4.7 kg
Environment
StandardsEN 60947-2
IEC 60947-2
Product certificationsGOST
IEC
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60664-1
IP degree of protectionIP40
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.000 cm
Package 1 Width16.000 cm
Package 1 Length29.000 cm
Package 1 Weight4.931 kg
Unit Type of Package 2S04
Number of Units in Package 23
Package 2 Height30.000 cm
Package 2 Width40.000 cm
Package 2 Length60.000 cm
Package 2 Weight15.443 kg
Unit Type of Package 3P12
Number of Units in Package 312
Package 3 Height45.000 cm
Package 3 Width80.000 cm
Package 3 Length120.000 cm
Package 3 Weight73.772 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV540306 | circuit breaker EasyPact CVS400F, 36 kA at 415 VAC, 400 A rating thermal magnetic TM-D trip unit, 3P 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!
Let's Chat