Introduction

Schneider Electric is renowned for its innovative electrical solutions, and it circuit breaker is no exception. In this article, we’ll explore the features, specifications, and benefits of this reliable and efficient circuit breaker.

Understanding the Schneider LV540316 EasyPact

What is the Schneider LV540316 EasyPact?

it is a high-performance circuit breaker designed to protect electrical circuits from overcurrents, short circuits, and other electrical faults. It belongs to Schneider Electric’s EasyPact series, known for its user-friendly design and robust construction.

Key Features and Specifications

Some of the key features of the Schneider LV540316 EasyPact include:

  • Durable construction: Built to withstand demanding environments.
  • High performance: Capable of handling heavy loads efficiently.
  • Advanced safety features: Includes mechanisms for thermal and magnetic protection to ensure safe operation.

The Importance of Circuit Breakers

What is a Circuit Breaker?

A circuit breaker is an essential component of any electrical system, designed to automatically interrupt the flow of electricity in the event of a fault. This helps prevent damage to the system and reduces the risk of fire or electrical hazards.

Role in Electrical Safety

Circuit breakers play a crucial role in maintaining electrical safety by:

  • Preventing overloads: They interrupt the flow of excessive current to prevent damage to wiring and appliances.
  • Protecting against short circuits: They quickly disconnect the circuit in the event of a short circuit, minimizing damage and risk.

Detailed Features of the LV540316

Design and Construction

it is built with durability in mind, featuring a robust construction that ensures reliable performance even in harsh conditions.

Performance Capabilities

With its high-performance capabilities, the LV540316 EasyPact can efficiently handle heavy loads, providing dependable protection for electrical systems.

Safety Features

This circuit breaker is equipped with advanced safety features, including thermal and magnetic protection mechanisms, to ensure safe and reliable operation.

Technical Specifications

Electrical Ratings

  • Rated current: Up to 630A
  • Breaking capacity: High breaking capacity suitable for a wide range of applications

Mechanical Endurance

The LV540316 EasyPact is designed for long-term reliability, with high mechanical endurance to withstand frequent operation.

Environmental Conditions

It is suitable for use in various environmental conditions, making it ideal for both indoor and outdoor applications.

Applications of the LV540316 EasyPact

Industrial Use

In industrial settings, the LV540316 EasyPact provides robust protection for machinery and equipment, ensuring uninterrupted operation and safety.

Commercial Use

For commercial buildings, this circuit breaker ensures the safety and reliability of essential electrical systems such as lighting, heating, and cooling.

Residential Use

In residential applications, the LV540316 EasyPact protects household electrical systems and appliances, providing peace of mind for homeowners.

Installation and Setup

Step-by-Step Installation Guide

  1. Turn off the main power supply.
  2. Mount the circuit breaker in the designated panel.
  3. Connect the input and output wires securely.
  4. Ensure all connections are tight and secure.
  5. Turn on the power and test the circuit breaker.

Important Considerations During Installation

  • Follow manufacturer guidelines: Adhere to the installation instructions provided by Schneider Electric.
  • Check connections: Ensure all electrical connections are properly secured to prevent faults.

Maintenance and Troubleshooting

Routine Maintenance Tips

  • Regular inspections: Periodically inspect the circuit breaker for signs of wear or damage.
  • Cleaning: Keep the breaker and its surroundings clean to prevent dust buildup.

Common Issues and How to Fix Them

  • Frequent tripping: This may indicate an overload or fault in the circuit. Check the load distribution and inspect for any faults.
  • Loose connections: Ensure all connections are tight and secure.

Comparing the LV540316 to Other Models

Comparison with Other Schneider Models

The LV540316 EasyPact offers a balance of performance, reliability, and affordability compared to other Schneider models in its range.

Comparison with Competitor Products

Compared to competitor products, the LV540316 EasyPact often provides superior performance and safety features, making it a preferred choice for many users.

Benefits of Using Schneider LV540316 EasyPact

Enhanced Safety

The LV540316 EasyPact’s advanced safety features provide maximum protection for electrical systems, minimizing the risk of accidents or damage.

Cost Efficiency

Its reliable performance and durable construction reduce the need for frequent maintenance or replacements, saving both time and money in the long run.

Reliability

With its robust design and high mechanical endurance, the LV540316 EasyPact offers dependable protection for electrical systems, ensuring uninterrupted operation.

SKU: LV540316 Category:
Main
Range EasyPact
Product name EasyPact CVS
Device short name CVS400N
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3D
Earth leakage protection (Vigi add on) Without
[In] rated current 400 A at 40 °C
Network type AC
utilisation category Category A
[Icu] Breaking capacity 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 400 A at 40 °C
Protection type Short-circuit protection (magnetic)
Overload protection (thermal)
Complementary
[Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
Network frequency 50/60 Hz
Breaking capacity code N
[Ics] rated service breaking capacity 70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
32 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 15000 cycles
Electrical durability 6000 cycles 415 V In conforming to IEC 60947-2
control type Toggle
Thermal protection adjustment range 280…400 A
Long time pick-up adjustment type Ir Adjustable
long time pick-up adjustment range 0.7…1 x In
Long time delay adjustment type Fixed
instantaneous pick-up adjustment type Ii Adjustable
instantaneous pick-up adjustment range 5…10 x In
Contact position indicator Yes
Mounting mode Fixed
mounting support Backplate
Upside connection Front
downside connection Front
Connections – terminals Screw connection
Connection pitch 45 mm
Compatibility code CVS400
Width 140 mm
Depth 110 mm
height 255 mm
Net weight 4.7 kg
Environment
Standards EN 60947-2
IEC 60947-2
product certifications GOST
IEC
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40
ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.800 cm
Package 1 Width 15.600 cm
Package 1 Length 28.700 cm
Package 1 Weight 4.916 kg
Unit Type of Package 2 S04
Number of Units in Package 2 3
Package 2 Height 30.000 cm
Package 2 Width 40.000 cm
Package 2 Length 60.000 cm
Package 2 Weight 15.508 kg
Contractual warranty
Warranty 18 months

Main Document

Data Sheet : LV540316 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider LV540316 EasyPact | circuit breaker EasyPact CVS400N, 50 kA at 415 VAC, 400 A rating thermal magnetic TM-D trip unit, 3P 3d”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024