Schneider METSEGLDM3141 Description

The Schneider METSEGLDM3141 is a part of the PowerLogic range of energy meters, offering advanced features for precise and efficient energy monitoring and management. Designed for diverse applications in residential, commercial, and industrial settings, this device provides accurate measurement and reliable data to optimize energy usage.

Key Features and Benefits

  1. Comprehensive Measurement: The METSEGLDM3141 measures a wide array of electrical parameters including voltage, current, power, and energy consumption, enabling detailed monitoring and management of energy use.
  2. High Accuracy: This meter ensures high accuracy in energy measurement, providing reliable data for effective energy management.
  3. Clear Display: The meter features an easy-to-read display that provides real-time data on energy consumption and other electrical parameters, facilitating easy monitoring and analysis.
  4. Communication Capabilities: The METSEGLDM3141 supports various communication protocols, allowing for seamless integration into energy management systems and enabling remote monitoring and control.
  5. Compact and Robust Design: Its compact design ensures easy installation in a variety of settings, including electrical panels and distribution boards, while its robust construction ensures durability and long-term performance.
  6. Data Logging: The meter comes with built-in data logging capabilities, allowing for the recording and storage of energy data over time. This feature is essential for detailed energy analysis and reporting.
  7. User-Friendly Installation: Designed for straightforward installation, the METSEGLDM3141 can be quickly and easily mounted, reducing setup time and complexity.
  8. Durable Construction: Made with high-quality materials, this energy meter is built to withstand harsh environmental conditions, ensuring reliability and longevity.
  9. Standards Compliance: The device complies with international standards, meeting rigorous requirements for safety, performance, and reliability.

Applications

  • Residential: Ideal for monitoring and managing energy consumption in homes, helping homeowners track and reduce their energy usage.
  • Commercial: Suitable for use in offices, retail spaces, and other commercial environments to monitor and optimize energy use.
  • Industrial: Effective for tracking energy consumption in industrial facilities, aiding in the optimization of energy use for machinery and equipment.
  • Energy Management Systems: Can be integrated into larger energy management systems for comprehensive monitoring and control of energy usage.

Installation and Maintenance

  • Installation: The METSEGLDM3141 is designed for easy installation with flexible mounting options. Clear instructions are provided to ensure proper setup.
  • Maintenance: Regular maintenance checks are recommended to ensure the meter operates at peak performance. Its durable construction minimizes the need for frequent maintenance.

Conclusion

The Schneider METSEGLDM3141 PowerLogic energy meter is a versatile and reliable solution for accurate energy monitoring and management. Its advanced features, high accuracy, and ease of integration make it an excellent choice for a wide range of applications, from residential to industrial settings. Trust the METSEGLDM3141 to provide precise and reliable energy data, helping you optimize energy usage and improve efficiency

SKU: METSEGLDM3141 Category:
brands

 

Main
Range Go Series
Product name GoLogic DM3000
Device short name GLDM3140 LED
Product or component type VAF PF meter
Complementary
Device application Remote monitoring
Motor control
Power distribution
Building management system
Energy monitoring
Type of measurement Current
Voltage
Frequency
RPM
Metering type Unbalance current
Calculated neutral current
Unbalance voltage
Rotation speed
Phase currents
Voltage U21, U32, U13, V1, V2, V3
Frequency
Average voltage Vavg
Average current Iavg
Power factor
Counter functions Power interruption
ON hour counting
[Us] rated supply voltage 48…277 V AC 45…65 Hz
48…277 V DC
Network frequency 50 Hz
60 Hz
[In] rated current 1 A
5 A
type of network 2P + N
2P
3P + N
3P
1P + N
Maximum power consumption in VA 4 VA at 240 V between phase and neutral
Maximum power consumption in W 2 W at 240 V
Display type 8 segments LED
Display colour Red
Messages display capacity 3 fields of 4 characters
Display digits 12 digit(s) – 14.2 mm in height
communication of data Reading of measurements
Instantaneous and demand values
Revolution speed
All counters
Tamperproof of settings Protected by access code
Sampling rate 32 samples/cycle
Measurement current 10…6000 mA
Signal Current 0.005…10 A (impedance 0.3 MOhm)6 x
Measurement voltage 80…480 V AC 50…60 Hz between phases
46…277 V AC 50…60 Hz between phase and neutral
100…999000 V AC 50…60 Hz with external VT
35…600 V AC 50…60 Hz full voltage range
Frequency measurement range 48…52 Hz
58…62 Hz
Measurement accuracy Active energy +/- 1 %
Reactive energy +/- 2 %
Apparent energy +/- 1 %
Active power +/- 1 %
Reactive power +/- 1 %
Apparent power +/- 1 %
Current +/- 0.5 %
Voltage +/- 0.5 %
Frequency +/- 0.05 % 48…52 Hz / 58…62 Hz
Frequency +/- 0.2 % 30…70 Hz
Power factor +/- 0.01
Harmonic distorsion (I THD & U THD) +/- 5 %
Accuracy class Class 1 active energy conforming to IEC 62053-21
Class 2 reactive energy conforming to IEC 62053-23
Class 1 apparent energy
Class 1 active power
Class 1 reactive power
Class 1 apparent power
Class 1 current
Class 1 voltage
Class 1 power factor
Class 5 harmonic distorsion (I THD & U THD)
Demand intervals 1 s
Local signalling Green LED: activity
Green LED: communication 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Communication port protocol Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2-wire, insulation 2500 V
Communication port support Screw terminal: RS485
Material Polycarbonate
Flame retardance V-0 conforming to UL 94
mounting mode Flush-mounted
Mounting support Framework
Installation category III
Type of installation Indoor installation
Measurement category Category III 80…480 V
Electrical insulation class Class II
Connections – terminals Current circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s)
Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
Communication: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s)
Tightening torque Current circuit: 0.9…1 N.m Philips No 2 screwdriver
Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver
Control circuit: 0.9…1 N.m Philips No 2 screwdriver
Communication: 0.5…0.6 N.m Philips no 1 screwdriver
Wire stripping length Current circuit: 3.68 mm
Voltage circuit: 7 mm
Control circuit: 7 mm
Communication: 7 mm
Standards IEC 61010-1:ed. 3
UL 61010-1:ed. 3
Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
Width 96 mm
Depth Outside : 13.9 mm
Panel : 48.8 mm
Height 96 mm
Net weight 300 g
Environment
Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class A
Emission tests conforming to FCC part 15 Subpart C
Emission tests conforming to FCC part 15 Subpart E
Overvoltage category III
IP degree of protection IP51 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity 5…95 % at 50 °C
Pollution degree 2
Ambient air temperature for operation -10…60 °C
ambient air temperature for storage -20…70 °C
Operating altitude <= 2000 m
Service life 7 year(s)
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 8.905 cm
Package 1 Width 11.903 cm
Package 1 Length 12.229 cm
Package 1 Weight 360 g
Unit Type of Package 2 S03
Number of Units in Package 2 18
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 6480 g
Unit Type of Package 3 P12
Number of Units in Package 3 288
Package 3 Height 75 cm
Package 3 Width 80 cm
Package 3 Length 120 cm
Package 3 Weight 133.5 kg

Main Document

Data Sheet : METSEGLDM3141

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider METSEGLDM3141 | power and energy meter, GoLogic DM3141, volt, amps and frequency meter, LED, power factor, Class 1.0, RS485”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024