-40%
, , ,

Schneider MVS16H3MF2L | EP MVS CB 1600A 65kA 3P MF ET2 fixed manual circuit breaker

Schneider Electric
Availability:

In stock


Schneider MVS16H3MF2L | EP MVS CB 1600A 65kA 3P MF ET2 fixed manual circuit breaker

195,945.48 EGP 326,575.80 EGP

In stock

Schneider MVS16H3MF2L | EP MVS CB 1600A 65kA 3P MF ET2 fixed manual circuit breaker

Technical Specifications

  • Model: MVS16H3MF2L
  • Brand: Schneider Electric
  • Series: EP MVS
  • Type: Manual Circuit Breaker
  • Rated Current: 1600A
  • Short-Circuit Withstand Rating: 65kA
  • Poles: 3 Poles (3P)
  • Type of Operation: Manual (MF)
  • Frame Type: Fixed
  • Interrupting Capacity: 65kA at 415V
  • Protection Function: Overload, Short-circuit, and Earth Fault protection

Key Features

  1. High Current Rating – With a current rating of 1600A, the MVS16H3MF2L circuit breaker is ideal for large industrial and commercial installations where high power is required.
  2. High Short-Circuit Withstand Capacity – The breaker offers an impressive 65kA short-circuit withstand rating, ensuring that it can safely handle high fault currents without damaging the electrical system.
  3. 3-Pole Configuration – The 3-pole design is perfect for three-phase systems, providing balanced protection across all three phases.
  4. Manual Operation – The manual operation (MF) feature allows operators to manually switch the circuit breaker on and off, making it suitable for applications requiring human intervention and control.
  5. Fixed Mounting – Designed for fixed installation, this circuit breaker is a reliable and stable option for permanent setups in power distribution panels and control panels.
  6. Reliable Protection – Protects against overload, short-circuit, and earth fault conditions, enhancing the safety and longevity of the electrical installation.

Applications

The Schneider MVS16H3MF2L circuit breaker is commonly used in various industrial, commercial, and utility applications that require reliable protection for high-power electrical circuits:

  1. Industrial Power Distribution – Suitable for use in industrial plants, factories, and manufacturing units where large electrical systems need protection.
  2. Commercial Buildings – Used in high-rise buildings, shopping malls, and office complexes to protect the electrical distribution systems.
  3. Energy Distribution Systems – Essential for transformer substations and power plants where high current protection is required.
  4. Critical Infrastructure – Applied in hospitals, data centers, and telecommunication facilities where reliable protection is critical to avoid system failure.
  5. Renewable Energy Systems – Used in solar and wind energy plants for protecting the electrical circuits against faults and overloads.
brands

Main
Range EasyPact
product name MVS16H
Device short name MVS16H
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3P 3d
[In] rated current 1600 A at 40 °C
network type AC
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code H
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category B
Trip unit name ET2I
Trip unit technology Electronic
Trip unit rating 1600 A
Complementary
Network frequency 50/60 Hz
control type Manually operated
Mounting mode Fixed
Mounting support Base plate
Rail
Connection position Vertical
Horizontal
Location of connection Rear
[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
Circuit breaker CT rating 1600 A
Breaking capacity 65 kA Icu at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 65 kA (Ics) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Connection pitch 115 mm without spreader
Contact position indicator Yes
[Icm] rated short-circuit making capacity 143 kA (Icm) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current 65 kA (1 s) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
50 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit protection functions LI
Protection type Overload protection (long time)
Instantaneous short-circuit protection
Fault indication Internal fault
Short-circuit
Overload
Long time pick-up adjustment type Ir Adjustable 9 settings
Long time pick-up adjustment range 0.4…1 x In
Long time delay adjustment type Adjustable 9 settings
[tr] long-time delay adjustment range 0.5…24 s at 6 x Ir
Thermal memory 20 minutes before and after tripping
Instantaneous pick-up adjustment type Ii Adjustable 9 settings
Instantaneous pick-up adjustment range 1.5…10 x Ir
Zone selective interlocking ZSI With
Current sensor rating range 400/2000 A
Maximum breaking time 25 ms
Maximum closing response time 70 ms
Height 352 mm
Width 422 mm
Depth 297 mm
Product weight 40 kg
Environment
Standards IEC 60947-2
Product certifications GOST
IEC
CCS
CCC
Pollution degree 4 conforming to IEC 60664-1
IP degree of protection IP40
Ambient air temperature for operation -5…70 °C
Ambient air temperature for storage -40…85 °C without control unit
-25…85 °C with control unit
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 42.0 cm
Package 1 Width 35.0 cm
Package 1 Length 50.0 cm
Package 1 Weight 46.133 kg
Contractual warranty
Warranty 18 months
Main
Range EasyPact
product name MVS16H
Device short name MVS16H
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3P 3d
[In] rated current 1600 A at 40 °C
network type AC
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code H
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category B
Trip unit name ET2I
Trip unit technology Electronic
Trip unit rating 1600 A
Complementary
Network frequency 50/60 Hz
control type Manually operated
Mounting mode Fixed
Mounting support Base plate Rail
Connection position Vertical Horizontal
Location of connection Rear
[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
Circuit breaker CT rating 1600 A
Breaking capacity 65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability Category B: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 4000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
Connection pitch 115 mm without spreader
Contact position indicator Yes
[Icm] rated short-circuit making capacity 143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current 65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit protection functions LI
Protection type Overload protection (long time) Instantaneous short-circuit protection
Fault indication Internal fault Short-circuit Overload
Long time pick-up adjustment type Ir Adjustable 9 settings
Long time pick-up adjustment range 0.4...1 x In
Long time delay adjustment type Adjustable 9 settings
[tr] long-time delay adjustment range 0.5…24 s at 6 x Ir
Thermal memory 20 minutes before and after tripping
Instantaneous pick-up adjustment type Ii Adjustable 9 settings
Instantaneous pick-up adjustment range 1.5...10 x Ir
Zone selective interlocking ZSI With
Current sensor rating range 400/2000 A
Maximum breaking time 25 ms
Maximum closing response time 70 ms
Height 352 mm
Width 422 mm
Depth 297 mm
Product weight 40 kg
Environment
Standards IEC 60947-2
Product certifications GOST IEC CCS CCC
Pollution degree 4 conforming to IEC 60664-1
IP degree of protection IP40
Ambient air temperature for operation -5…70 °C
Ambient air temperature for storage -40…85 °C without control unit -25…85 °C with control unit
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 42.0 cm
Package 1 Width 35.0 cm
Package 1 Length 50.0 cm
Package 1 Weight 46.133 kg
Contractual warranty
Warranty 18 months

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider MVS16H3MF2L | EP MVS CB 1600A 65kA 3P MF ET2 fixed manual circuit breaker”

There are no reviews yet.

SHOPPING CART

close