Schneider R9F32216: The Ultimate Guide

Schneider Electric is a global leader in energy management and automation, renowned for its innovative and reliable products. One of their standout products is it, a highly efficient and versatile device designed to enhance electrical safety and performance in various settings.

What is the Schneider R9F32216?

it is a modular circuit breaker designed to provide advanced protection and control in both residential and commercial electrical systems. This model is part of Schneider Electric’s extensive range of circuit protection solutions, known for their reliability and cutting-edge features. It plays a crucial role in safeguarding electrical installations against overloads, short circuits, and other electrical faults.

Key Features of the Schneider R9F32216

Compact and User-Friendly Design

it features a compact and modular design, making it easy to install and integrate into existing electrical panels. Its user-friendly interface ensures that both professionals and homeowners can operate it with ease.

Advanced Safety Features

Safety is a top priority for Schneider Electric, and it is no exception. It includes advanced safety features such as thermal and magnetic trip mechanisms, which provide reliable protection against overloads and short circuits. Additionally, it is designed to prevent accidental contact with live parts, enhancing overall safety.

High Performance and Reliability

it is engineered to deliver high performance and reliability. It is capable of handling a wide range of electrical loads, ensuring consistent and stable operation even in demanding environments. Its robust construction and high-quality materials contribute to its long-lasting durability.

Technical Specifications

Power Ratings and Capacity

it is rated for a current capacity of 16A, making it suitable for a variety of residential and commercial applications. It is designed to handle standard electrical loads efficiently.

Voltage and Current Requirements

This model operates on a single-phase power supply with a voltage rating of 230/400V AC. It is compatible with most standard electrical systems, ensuring seamless integration.

Environmental Ratings and Certifications

it is built to withstand various environmental conditions. It has an IP20 rating, indicating protection against solid objects and ensuring adequate ventilation. Additionally, it is certified to meet international safety and performance standards, providing peace of mind to users.

Applications of the Schneider R9F32216

Residential Applications

it is ideal for residential electrical systems, providing reliable protection for household circuits. It helps prevent electrical hazards and ensures the safety of residents.

Commercial Applications

In commercial settings, the R9F32216 is used to protect electrical installations in offices, retail spaces, and other commercial buildings. Its robust performance and safety features make it suitable for these environments.

Specific Use Cases

  • Lighting Circuits: Ensures stable operation and protection for lighting systems.
  • Appliance Protection: Safeguards household and commercial appliances from electrical faults.
  • General Circuit Protection: Provides overall protection for various electrical circuits.

Installation and Setup

Step-by-Step Installation Guide

  1. Preparation: Ensure the power is turned off and the installation area is safe.
  2. Mounting: Secure the R9F32216 in the designated slot of the electrical panel.
  3. Wiring: Connect the input and output wires according to the wiring diagram provided by Schneider Electric.
  4. Configuration: Adjust the settings on the R9F32216 as per the application requirements.
  5. Testing: Perform a test run to ensure the circuit breaker is functioning correctly and providing the expected protection.

Safety Precautions and Considerations

  • Always follow local electrical codes and regulations.
  • Use appropriate personal protective equipment (PPE) during installation.
  • Verify all connections are secure and correctly configured.

Operating the Schneider R9F32216

Basic Operation Instructions

  • Use the handle to switch the circuit breaker on and off.
  • Monitor the status indicator to check the operational status.
  • Reset the breaker manually in case of a trip due to an overload or short circuit.

Advanced Settings and Configurations

  • Adjustable Trip Settings: Customize the thermal and magnetic trip settings based on specific application needs.
  • Remote Monitoring: Integrate with Schneider Electric’s monitoring systems for real-time status updates and remote control.

Maintenance Tips

Regular Maintenance Routines

  • Visual Inspections: Regularly check for any signs of wear, damage, or overheating.
  • Cleaning: Keep the circuit breaker and panel clean from dust and debris.
  • Functional Tests: Periodically test the circuit breaker to ensure it is operating correctly.

Troubleshooting Common Issues

  • Nuisance Tripping: Check for any issues with the connected load or wiring.
  • Overheating: Ensure proper ventilation and load management.
  • Faulty Operation: Verify all connections and settings are correct, and consult the user manual for guidance.
SKU: R9F32216 Category:
Main
Range Resi9
product or component type Miniature circuit-breaker
Device application Distribution
poles description 2P
Number of protected poles 2
[In] rated current 16 A
Network type AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Standards EN/IEC 60898-1
Quality labels IMQ
Complementary
Network frequency 50/60 Hz
[Ue] rated operational voltage 400 V AC 50/60 Hz
Magnetic tripping limit 5…10 x In AC
Limitation class 3 conforming to EN/IEC 60898-1
[Ui] rated insulation voltage 440 V AC
[Uimp] rated impulse withstand voltage 4 kV
Control type Toggle
local signalling ON/OFF indication
mounting mode Clip-on
mounting support DIN rail
9 mm pitches 4
Height 81 mm
Width 36 mm
Depth 72 mm
Embedding depth 44 mm
net weight 240 g
Colour White (RAL 9003)
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections – terminals Tunnel type terminals (top or bottom) – 1…25 mm² – rigid
Tunnel type terminals (top or bottom) – 1…16 mm² – flexible with ferrule
Tunnel type terminals (top or bottom) – 1…16 mm² – flexible
Wire stripping length 14 mm
Tightening torque 2 N.m
Earth-leakage protection Without
Environment
IP degree of protection IP20
Pollution degree 2 conforming to EN/IEC 60898-1
Overvoltage category III
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Ambient air temperature for operation -25…60 °C
Ambient air temperature for storage -40…60 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.5 cm
Package 1 Width 3.6 cm
Package 1 Length 8.5 cm
Package 1 Weight 188.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 6
Package 2 Height 8.2 cm
Package 2 Width 8.8 cm
Package 2 Length 22 cm
Package 2 Weight 1.169 kg
Unit Type of Package 3 S03
Number of Units in Package 3 72
Package 3 Height 30 cm
Package 3 Width 30 cm
Package 3 Length 40 cm
Package 3 Weight 14.52 kg

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider R9F32216 | Miniature circuit breaker (MCB), Resi9, 2P, 16A, C curve, 4500A (IEC/EN 60898-1)”

There are no reviews yet.

SHOPPING CART

close
error: Content is protected !!

congratulations

شكرا لك علي التسجيل ويشرفنا تواجدك معانا لانك شريك لدينا مهم

فندق انتركونتيننتال سيتى ستارز قاعة السرايا بتاريخ 22-09-2024